Burnout resistance; Cooling phase; Glulam (GLT); Natural fire tests; Structural failure; Timber columns; Wood crib; Compartment fires; Fire tests; Natural fire; Natural fire test; Wood cribs; Chemistry (all); Materials Science (all); Safety, Risk, Reliability and Quality; Physics and Astronomy (all)
Abstract :
[en] Timber framing is increasingly used as a load-bearing structural system in mid-rise and high-rise buildings. While extensive data exists from standard furnace tests, there is a lack of data on the fire performance of loaded timber members in full-scale compartment fires. Compartment fire tests are crucial to investigate a structure's performance under conditions where the fire is let to grow naturally with the fuel and oxygen present in the room and then let to cool down as the fuel burns out. This paper presents the findings from six fire tests performed on glue laminated timber columns in a custom-built compartment. Wood cribs are used as fuel. The columns, 3680 mm long with a 280 × 280 mm2 section, are subjected to constant axial loading during the whole fire duration. Column design and loading are based on a 60-min fire resistance. The tests vary in opening factor, fire load, and wood crib size. Column failure was observed in the six tests, with failure times ranging from 35 to 71 min. In four of the tests, failure occurred after the gas temperature had started to cool down. Comparisons with tests on similar columns made in a fire resistance furnace allow comparing charring rates observed in standard conditions and in natural fires.
Disciplines :
Civil engineering
Author, co-author :
Renard, Silvio ; CERIB Fire Testing Centre, Epernon, France
Robert, Fabienne; CERIB Fire Testing Centre, Epernon, France
Franssen, Jean-Marc ; Université de Liège - ULiège > Département ArGEnCo ; Liege University, Belgium
Zehfuß, Jochen; Technische Universität Braunschweig (iBMB), Braunshweigh, Germany
McNamee, Robert; RISE Research Institutes, Lund, Sweden
Bamonte, Patrick; Politecnico di Milano, Italy
Gernay, Thomas; Johns Hopkins University, Baltimore, United States
Language :
English
Title :
Structural behavior of timber columns in wood crib compartment fire tests
Alternative titles :
[fr] Comportement structurel de colonnes en bois lors d'essais au feu de bois dans un compartiment
Pomponi, F., Moncaster, A., Embodied carbon mitigation and reduction in the built environment – what does the evidence say?. J. Environ. Manag. 181 (2016), 687–700, 10.1016/j.jenvman.2016.08.036.
Law, A., Bisby, L., The rise and rise of fire resistance. Fire Saf. J., 116, 2020, 103188, 10.1016/j.firesaf.2020.103188.
Law, A., Hadden, R., We need to talk about timber: fire safety design in tall buildings. The Structural Engineer, 2020.
Lange, D., Sjöström, J., Schmid, J., Brandon, D., Hidalgo, J., A comparison of the conditions in a fire resistance furnace when testing combustible and non-combustible construction. Fire Technol. 56 (2020), 1621–1654, 10.1007/s10694-020-00946-6.
Wiesner, F., Bartlett, A., Mohaine, S., Robert, F., McNamee, R., Mindeguia, J.-C., Bisby, L., Structural capacity of one-way spanning large-scale cross-laminated timber slabs in standard and natural fires. Fire Technol. 57 (2021), 291–311, 10.1007/s10694-020-01003-y.
Gernay, T., Zehfuß, J., Brunkhorst, S., Robert, F., Bamonte, P., McNamee, R., Mohaine, S., Franssen, J., Experimental investigation of structural failure during the cooling phase of a fire: timber columns. Fire Mater. 47 (2023), 445–460, 10.1002/fam.3110.
Kotsovinos, P., Rackauskaite, E., Christensen, E., Glew, A., O'Loughlin, E., Mitchell, H., Amin, R., Robert, F., Heidari, M., Barber, D., Rein, G., Schulz, J., Fire dynamics inside a large and open‐plan compartment with exposed timber ceiling and columns. CodeRed #01, Fire Mater. 47 (2023), 542–568, 10.1002/fam.3049.
Wiesner, F., Hadden, R., Deeny, S., Bisby, L., Structural fire engineering considerations for cross-laminated timber walls. Constr. Build. Mater., 323, 2022, 126605, 10.1016/j.conbuildmat.2022.126605.
Mitchell, H., Amin, R., Heidari, M., Kotsovinos, P., Rein, G., Structural hazards of smouldering fires in timber buildings. Fire Saf. J., 140, 2023, 103861, 10.1016/j.firesaf.2023.103861.
Casagrande, D., Brandon, D., D'Arenzo, G., Viau, C., Design of Taller Timber Buildings Subjected to Accidental Loads: a State-Of-The-Art Review, COST Action CA 20139. 2022.
Brandon, D., Sjöström, J., Temple, A., Hallberg, E., Kahl, F., Fire Safe implementation of visible mass timber in tall buildings–compartment fire testing. Available: https://urn.kb.se/resolve?urn=urn:nbn:se:ri:diva-58153, 2021.
Gorska, C., Hidalgo, J.P., Torero, J.L., Fire dynamics in mass timber compartments. Fire Saf. J., 120, 2021, 103098, 10.1016/j.firesaf.2020.103098.
McGregor, C., Contribution of Cross Laminated Timber Panels to Room Fires. 2013, Carleton University, Thesis Available: https://repository.library.carleton.ca/downloads/hm50ts23g.
Su, J., Lafrance, P.-S., Hoehler, M., Bundy, M., Fire Safety Challenges of Tall Wood Buildings-phase 2: Task 3-cross Laminated Timber Compartment Fire Tests. 2018.
Nothard, S., Lange, D., Hidalgo, J.P., Gupta, V., McLaggan, M.S., Wiesner, F., Torero, J.L., Factors influencing the fire dynamics in open-plan compartments with an exposed timber ceiling. Fire Saf. J., 129, 2022, 103564, 10.1016/j.firesaf.2022.103564.
Mitchell, H., Kotsovinos, P., Richter, F., Thomson, D., Barber, D., Rein, G., Review of fire experiments in mass timber compartments: current understanding, limitations, and research gaps. Fire Mater. 47 (2023), 415–432, 10.1002/fam.3121.
Kinjo, H., Katakura, Y., Hirashima, T., Yusa, S., Saito, K., Deflection behavior and load-bearing period of structural glued laminated timber beams in fire including cooling phase. JSFE 9 (2018), 287–299, 10.1108/JSFE-01-2017-0009.
Hirashima, T., Yamashita, H., Ishi, S., Igarashi, T., Baba, S., Someya, T., Deformation behaviour and failure time of glued laminated timber columns in fire. Proceedings of the 11th International Conference on Structures in Fire (SiF2020), 2020, The University of Queensland, Online, 10.14264/beec17b.
Gernay, T., Fire resistance and burnout resistance of timber columns. Fire Saf. J., 122, 2021, 103350, 10.1016/j.firesaf.2021.103350.
Renard, S., Gernay, T., Robert, F., Zehfuß, J., McNamee, R., Bamonte, P., Franssen, J.-M., Parametric experimental study on GLT columns stability during natural fire tests including the cooling phase. CMM–Portuguese Steelwork Association, 2024, Portugal.
CEN. Eurocode 1: Actions on Structures - Part 1-1: General Actions - Densities, Self-Weight, Imposed Loads for Buildings. 2002.
CEN. prEN 1995-1-2: Eurocode 5 – Design of Timber Structures Part 1-2: General – Structural Fire Design. 2020.
CEN. EN 14080: Timber Structures – Glued Laminated Timber and Glued Solid Timber – Requirements. 2013.
Heskestad, G., Modeling of enclosure fires. Symposium (International) on Combustion, 14, 1973, 1021–1030, 10.1016/S0082-0784(73)80092-X.
McAllister, S., Finney, M., Burning rates of wood cribs with implications for wildland fires. Fire Technol. 52 (2016), 1755–1777, 10.1007/s10694-015-0543-5.
CEN. EN 1995-1-2: Eurocode 5 – Design of Timber Structures - Part 1-2: General - Structural Fire Design. 2004.
Robert, F., Franssen, J.-M., Zehfuß, J., Brunkhorst, S., Bamonte, P., Renard, S., McNamee, R., Gernay, T., Natural Fire Tests on GLT Columns Including the Cooling Down Phase. 2023, Curran Associates, Inc, Red Hook, United States-New York Available: https://orbi.uliege.be/handle/2268/306216.
CEN. EN 1991-1-2: Eurocode 1: Actions on Structures - Part 1-2: General Actions - Actions on Structures Exposed to Fire. 2002.
Lucherini, A., Pitelková, D.Š., Mozer, V., Predicting the effective char depth in timber elements exposed to natural fires, including the cooling phase. WCTE, 2023, 1681–1690 2023.
CEN. EN 1363-1: Fire Resistance Tests - Part 1: General Requirements. 2020.