[en] Vitamin D3 is a key micronutrient whose intakes are inadequate for most populations worldwide. Supplementation with medicines or food supplements is commonly prescribed to correct this imbalance and the quality of these products must be ensured. In this context, a generic methodology for the assay of vitamin D3 in oily formulations is proposed using supercritical fluid chromatography coupled to mass spectrometry (SFC-MS). It is in line with green analytical chemistry principles and combines the use of i) a fast and robust analytical method (4.0 min analysis time) ii) an easy sample preparation compatible with high throughput analysis (“dilute-and-shoot” approach) and iii) a relevant control strategy. Seventeen products from multiple manufacturers and encompassing a large content range were evaluated in this study. They were classified in four groups to streamline their processing considering the use of a matrix-matched calibration procedure. Matrix effect was thoroughly studied and was found to be low (99-106%), stable intra/inter-series and comparable between the different groups and types of matrices. The implemented control strategy was based on a three-level system suitability tests (SST). Level 1 SST: resolution of the critical pair that was above 1.5 for all analysis series. Level 2 SST: evaluation of the adequacy of the calibration for a QC sample in terms of recovery that was between 97-104% with a variability between 1-2%. Level 3 SST: method trueness that was between 95-102%. Sample analysis highlighted differences in types of products and dosage forms. This is the first study to propose a complete strategy for the quality control of vitamin D3 oily formulations and should prove useful in QC laboratories.
Disciplines :
Pharmacy, pharmacology & toxicology
Author, co-author :
Jambo, Hugues ; Université de Liège - ULiège > Département de pharmacie > Chimie analytique
Dispas, Amandine ; Université de Liège - ULiège > Département de pharmacie > Chimie analytique
Hubert, Cédric ; Université de Liège - ULiège > Département de pharmacie > Chimie analytique
Lecomte, Frédéric ; Université de Liège - ULiège > Département de pharmacie > Législation et réglementation pharmaceutiques
Ziemons, Eric ; Université de Liège - ULiège > Département de pharmacie > Chimie analytique
Hubert, Philippe ; Université de Liège - ULiège > Département de pharmacie > Chimie analytique
Language :
English
Title :
Generic SFC-MS methodology for the quality control of vitamin D3 oily formulations
Vitamin D - Health Professional Fact Sheet, (n.d.). 〈https://ods.od.nih.gov/factsheets/VitaminD-HealthProfessional/〉 (accessed June 02, 2021).
Christakos, S., Li, S., De La Cruz, J., Bikle, D.D., New developments in our understanding of vitamin metabolism, action and treatment. Metabolism 98 (2019), 112–120, 10.1016/j.metabol.2019.06.010.
Bendik, I., Friedel, A., Roos, F.F., Weber, P., Eggersdorfer, M., Vitamin D: a critical and essential micronutrient for human health. Front. Physiol. 5:JUL (2014), 1–14, 10.3389/fphys.2014.00248.
Lockau, L., Atkinson, S.A., Vitamin D's role in health and disease: How does the present inform our understanding of the past?. Int. J. Paleopathol. 23 (2018), 6–14, 10.1016/j.ijpp.2017.11.005.
European Food Safety Authority (EFSA), Scientific Opinion on the Tolerable Upper Intake Level of vitamin D. EFSA J. 10 (2012), 1–45, 10.2903/j.efsa.2012.2813.
Wan, M., Patel, A., Patel, J.P., Rait, G., Jones, S., Shroff, R., Quality and use of unlicensed vitamin D preparations in primary care in England: Retrospective review of national prescription data and laboratory analysis. Br. J. Clin. Pharm., 2020, 1–9, 10.1111/bcp.14521.
Restaino, O.F., Finamore, R., Stellavato, A., Diana, P., Bedini, E., Trifuoggi, M., De Rosa, M., Schiraldi, C., European chondroitin sulfate and glucosamine food supplements: A systematic quality and quantity assessment compared to pharmaceuticals. Carbohydr. Polym., 222, 2019, 114984, 10.1016/j.carbpol.2019.114984.
Garg, S., Sabri, D., Kanji, J., S, P., Lee, Y., Svirskis, D., Evaluation of vitamin d medicines and dietary supplements. J. Nutr. Health Aging 17 (2013), 2–5.
European Medicines Agency (EMA), Specifications and control tests on the finished product. Directive 75/318/EEC, (1991). 〈https://www.ema.europa.eu/en/specifications-control-tests-finished-product〉.
European Comission, Guidance document for competent authorities, tolerances for the control of compliance of nutrient values declared on a label with EU legislation, (2012). 〈https://ec.europa.eu/food/safety/labelling_nutrition/supplements_en〉.
Yin, S., Yang, Y., Wu, L., Li, Y., Sun, C., Recent advances in sample preparation and analysis methods for vitamin D and its analogues in different matrices. TrAC Trends Anal. Chem. 110 (2019), 204–220, 10.1016/j.trac.2018.11.008.
Byrdwell, W.C., “dilute-and-shoot” triple parallel mass spectrometry method for analysis of vitamin D and triacylglycerols in dietary supplements. Anal. Bioanal. Chem. 401 (2011), 3317–3334, 10.1007/s00216-011-5406-4.
Hicks, M.B., Farrell, W., Aurigemma, C., Lehmann, L., Weisel, L., Nadeau, K., Lee, H., Moraff, C., Wong, M., Huang, Y., Ferguson, P., Making the move towards modernized greener separations: Introduction of the analytical method greenness score (AMGS) calculator. Green. Chem. 21 (2019), 1816–1826, 10.1039/c8gc03875a.
Tarafder, A., Metamorphosis of supercritical fluid chromatography to SFC: an overview. TrAC Trends Anal. Chem. 81 (2016), 3–10, 10.1016/j.trac.2016.01.002.
Guillarme, D., Desfontaine, V., Heinisch, S., Veuthey, J.L., What are the current solutions for interfacing supercritical fluid chromatography and mass spectrometry?. J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 1083 (2018), 160–170, 10.1016/j.jchromb.2018.03.010.
Tarafder, A., Designs and methods for interfacing SFC with MS. J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 1091 (2018), 1–13, 10.1016/j.jchromb.2018.05.003.
Andri, B., Dispas, A., Klinkenberg, R., Streel, B., Marini, R.D., Ziémons, E., Hubert, P., Is supercritical fluid chromatography hyphenated to mass spectrometry suitable for the quality control of vitamin D3 oily formulations?. J. Chromatogr. A 1515 (2017), 209–217, 10.1016/J.CHROMA.2017.07.057.
Nováková, L., Sejkorová, M., Smolková, K., Plachká, K., Švec, F., The benefits of ultra-high-performance supercritical fluid chromatography in determination of lipophilic vitamins in dietary supplements. Chromatographia 82 (2019), 477–487, 10.1007/s10337-018-3666-2.
Feng, L., Wu, L., Guo, Y., Hamada, N., Hashi, Y., Li, X., Cao, L., Determination of vitamin D3 in daily oily supplements by a two-dimensional supercritical fluid chromatography-liquid chromatography-mass spectrometry system. J. Chromatogr. A, 1629, 2020, 461510, 10.1016/j.chroma.2020.461510.
Andri, B., Lebrun, P., Dispas, A., Klinkenberg, R., Streel, B., Ziemons, E., Marini, R.D., Hubert, P., Optimization and validation of a fast supercritical fluid chromatography method for the quantitative determination of vitamin D3 and its related impurities. J. Chromatogr. A 1491 (2017), 171–181, 10.1016/j.chroma.2017.01.090.
Zhou, W., Yang, S., Wang, P.G., Matrix effects and application of matrix effect factor. Bioanalysis 9 (2017), 1839–1844, 10.4155/bio-2017-0214.
ICH, Q10 Guideline on Pharmaceutical Quality System, (2008).
Deidda, R., Orlandini, S., Hubert, P., Hubert, C., Risk-based approach for method development in pharmaceutical quality control context: a critical review. J. Pharm. Biomed. Anal. 161 (2018), 110–121, 10.1016/j.jpba.2018.07.050.
Masson, P., Quality control techniques for routine analysis with liquid chromatography in laboratories. J. Chromatogr. A 1158 (2007), 168–173, 10.1016/j.chroma.2007.03.003.
Declerck, S., Vander Heyden, Y., Mangelings, D., Defining a system suitability limit to decide on column deterioration and to facilitate column transfers in chiral supercritical fluid chromatography. Anal. Bioanal. Chem. 412 (2020), 6221–6230, 10.1007/s00216-019-02173-7.
Cholecalciferol concentrate (oily form), Monograph 00575, European Pharmacopoeia 10.0 (2020).
Cholecalciferol solution, United States Pharmacopoeia (USP), USP43-NF38 (2020), 987.
Dong, X., Tsong, Y., Shen, M., Statistical considerations in setting product specifications. J. Biopharm. Stat. 25 (2015), 280–294, 10.1080/10543406.2014.972511.