Rejection of pulse related artefact (PRA) from continuous electroencephalographic (EEG) time series recorded during functional magnetic resonance imaging (fMRI) using constraint independent component analysis (cICA).
[en] Rejection of the pulse related artefact (PRA) from electroencephalographic (EEG) time series recorded simultaneously with fMRI data is difficult, particularly during NREM sleep because of the similarities between sleep slow waves and PRA, in both temporal and frequency domains and the need to work with non-averaged data. Here we introduce an algorithm based on constrained independent component analysis (cICA) for PRA removal. This method has several advantages: (1) automatic detection of the components corresponding to the PRA; (2) stability of the solution and (3) computational treatability. Using multichannel EEG recordings obtained in a 3 T MR scanner, with and without concomitant fMRI acquisition, we provide evidence for the sensitivity and specificity of the method in rejecting PRA in various sleep and waking conditions.
Disciplines :
Neurology
Author, co-author :
Leclercq, Yves ; Université de Liège - ULiège > Centre de recherches du cyclotron
Balteau, Evelyne ; Université de Liège - ULiège > Centre de recherches du cyclotron
Dang Vu, Thien Thanh ; Université de Liège - ULiège > Département des sciences cliniques > Neurologie
Schabus, M.
Luxen, André ; Université de Liège - ULiège > Département de chimie (sciences) > Chimie organique de synthèse - Centre de recherches du cyclotron
Maquet, Pierre ; Centre Hospitalier Universitaire de Liège - CHU > Neurologie Sart Tilman
Phillips, Christophe ; Université de Liège - ULiège > Centre de recherches du cyclotron - Dép. d'électric., électron. et informat. (Inst.Montefiore)
Language :
English
Title :
Rejection of pulse related artefact (PRA) from continuous electroencephalographic (EEG) time series recorded during functional magnetic resonance imaging (fMRI) using constraint independent component analysis (cICA).
Allen P.J., Polizzi G., Krakow K., Fish D.R., and Lemieux L. Identification of EEG events in the MR scanner: the problem of pulse artifact and a method for its subtraction. Neuroimage 8 3 (1998) 229-239
Allen P.J., Josephs O., and Turner R. A method for removing imaging artifact from continuous EEG recorded during functional MRI. Neuroimage 12 2 (2000) 230-239
Bell A.J., and Sejnowski T.J. An information-maximization approach to blind separation and blind deconvolution. Neural Comput. 7 6 (1995) 1129-1159
Benar C.G., Aghakhani Y., Wang Y., Izenberg A., Al-Asmi A., Dubeau F., and Gotman J. Quality of EEG in simultaneous EEG-fMRI for epilepsy. Clin. Neurophysiol. 114 3 (2003) 569-580
Bonmassar G., Purdon P.L., Jääskeläinen I.P., Chiappa K., Solo V., Brown E.N., and Belliveau J.W. Motion and ballistocardiogram artifact removal for interleaved recording of EEG and EPs during MRI. Neuroimage 16 4 (2002) 1127-1141
Briselli E., Garreffa G., Bianchi L., Bianciardi M., Macaluso E., Abbafati M., Marciani M.G., and Maraviglia B. An independent component analysis-based approach on ballistocardiogram artifact removing. Magn. Reson. Imaging 24 4 (2006) 393-400
Buzsaki G. The hippocampo-neocortical dialogue. Cereb. Cortex 6 (1996) 81-92
Czisch M., Wetter T.C., Kaufmann C., Pollmacher T., Holsboer F., and Auer D.P. Altered processing of acoustic stimuli during sleep: reduced auditory activation and visual deactivation detected by a combined fMRI/EEG study. Neuroimage 16 1 (2002) 251-258
Debener S., Strobel A., Sorger B., Peters J., Kranczioch C., Engel A.K., and Goebel R. Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: removal of the ballistocardiogram artefact. Neuroimage 34 2 (2007) 587-597
Debener S., Mullinger K.J., Niazy R.K., and Bowtell R.W. Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 T static magnetic field strength. Int. J. Psychophysiol. 67 3 (2008) 189-199
Dijk D.J., Shanahan T.L., Duffy J.F., Ronda J.M., and Czeisler C.A. Variation of electroencephalographic activity during non-rapid eye movement and rapid eye movement sleep with phase of circadian melatonin rhythm in humans. J. Physiol. 505 Pt 3 (1997) 851-858
Finelli L.A., Jung T.P., Duann J.R., Haist F., Makeig S., and Sejnowski T.J. Information theoric modeling and removal of artefacts from EEG recordings during fMR imaging. 9th Annu. Meeting Organization for Human Brain Mapping (2003)
Goldman R.I., Stern J.M., Engel J., and Cohen M.S. Acquiring simultaneous EEG and functional MRI. Clin. Neurophysiol. 111 11 (2000) 1974-1980
Grouiller F., Vercueil L., Krainik A., Segebarth C., Kahane P., and David O. A comparative study of different artefact removal algorithms for EEG signals acquired during functional MRI. Neuroimage 38 1 (2007) 124-137
Han J.Y., Lee H.R., Lee S.Y., Choi H.Y., and Kim J.G. ICA-based spatial filters to reduce cardioballistic noises in EEG signals acquired inside the MRI magnet. Prc. Int. Mag. Reson. Med. 11 (2004) 1101
Huber R., Ghilardi M.F., Massimini M., and Tononi G. Local sleep and learning. Nature 430 (2004) 78-81
Hyvarinen A. Fast and robust fixed-point algorithms for independent component analysis. IEEE Trans. Neural Netw. 10 3 (1999) 626-634
Hyvarinen A. Independent component analysis: algorithms and applications. IEEE Trans. Neural Netw. 13 4-5 (2000) 411-430
Kim K.H., Yoon H.W., and Park H.W. Improved ballistocardiac artifact removal from the electroencephalogram recorded in fMRI. Neurosci. Methods 135 1-2 (2004) 193-203
Laufs H., Kleinschmidt A., Beyerle A., Eger E., Salek-Haddadi A., Preibisch C., and Krakow K. EEG-correlated fMRI of human alpha activity. Neuroimage 19 4 (2003) 1463-1476
Liebenthal E., Ellingson M.L., Spanaki M.V., Prieto T.E., Ropella K.M., and Binder J.R. Simultaneous ERP and fMRI of the auditory cortex in a passive oddball paradigm. Neuroimage 19 4 (2003) 1395-1404
Lu W., and Rajapakse J.C. Constrained independent component analysis. Adv. Neural Inf. Process. Syst. 13 (2001) 570-576
MacQueen J.B. Some methods for classification and analysis of multivariate observations. Proceedings of 5th Berkeley Symposium on Mathematical Statistics and Probability (1967)
Mantini D., Perrucci M.G., Cugini S., Ferretti A., Romani G.L., Gratta C., and Del. Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis. Neuroimage 34 2 (2007) 598-607
Masterton R.A.J., Abbott D.F., Fleming S.W., and Jackson G.D. Measurement and reduction of motion and ballistocardiogram artefacts from simultaneous EEG and fMRI recordings. Neuroimage 37 1 (2007) 202-211
Moosmann M., Ritter P., Krastel I., Brink A., Thees S., Blankenburg F., Taskin B., Obrig H., and Villringer A. Correlates of alpha rhythm in functional magnetic resonance imaging and near infrared spectroscopy. Neuroimage 20 1 (2003) 145-158
Mukhopadhay S., and Ray G.C. A new interpretation of non linear energy operator and its efficacy in spike detection. IEEE Trans. Biomed. Eng. 45 2 (1998) 180-187
Nakamura W., Anami K., Mori T., Saitoh O., Cichocki A., and Amari S. Removal of ballistocardiogram artifacts from simultaneously recorded EEG and fMRI data using independent component analysis. IEEE Trans. Biomed. Eng. 53 7 (2006) 1294-1308
Niazy R., Ianetti G., Brady M., Matthews P., and Smith S. A multi-subject study of motor task modulation of EEG-alpha-rhythm/FMRI correlation. Tenth Int. Conf. on Functional Mapping of the Human Brain (2004)
Niazy R.K., Beckmann C.F., Iannetti G.D., Brady J.M., and Smith S.M. Removal of FMRI environment artifacts from EEG data using optimal basis sets. Neuroimage 28 3 (2005) 720-737
Phillips C., Thielen G., and Maquet P. Iteratively applied ICA to reject ballisto-cardiogram artefact of EEG data acquired during sleep fMRI. Human Brain Mapping, Florence (2006)
Rechtschaffen A., and Kales A. A manual of standardized terminology, techniques and scoring system for sleep stages of human subjects (1968), Washington DC
Schabus M., Dang-Vu T.T., Albouy G., Balteau E., Boly M., Carrier J., Darsaud A., Degueldre C., Desseilles M., Gais S., Phillips C., Rauchs G., Schnakers C., Sterpenich V., Vandewalle G., Luxen A., and Maquet P. Hemodynamic cerebral correlates of sleep spindles during human non-rapid eye movement sleep. Proc. Natl. Acad. Sci. U. S. A. 104 32 (2007) 13164-13169
Seeck M., Michel C.M., Spinelli L., and Lazeyras F. EEG mapping and functional MRI in presurgical epilepsy evaluation. Rev. Neurol. (Paris) 157 8-9 Pt 1 (2001) 747-751
Sijbers J., Audekerke J., Van, Verhoye M., der Linden A., Van, Dyck D., and Van. Reduction of ECG and gradient related artifacts in simultaneously recorded human EEG/MRI data. Magn. Reson. Imaging 18 (2000) 881-886
Srivastava G., Crottaz-Herbette S., Lau K.M., Glover G.H., and Menon V. ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner. Neuroimage 24 1 (2005) 50-60
Tong S., Bezerianos A., Paul J., Zhu Y., and Thakor N. Removal of ECG interference from the EEG recordings in small animals using independent component analysis. J. Neurosci. Methods 108 1 (2001) 11-17
Vincent J.L., Larson-Prior L.J., Zempel J.M., and Snyder A.Z. Moving GLM ballistocardiogram artifact reduction for EEG acquired simultaneously with fMRI. Clin. Neurophysiol. 118 5 (2007) 981-998
Wan X., Iwata K., Riera J., Ozaki T., Kitamura M., and Kawashima R. Artifact reduction for EEG/fMRI recording: nonlinear reduction of ballistocardiogram artifacts. Clin. Neurophysiol. 117 (2006) 668-680