Steel; Fire resistance; cellular beam; Membrane action; Bailey's method
Abstract :
[en] The aim of this document is to describe the calculation methods developed to assess the resistance of simply supported cellular beams in fire conditions. This development has been made in the scope of the RFCS FiCEB+ [23] and in the scope of the PHD of O.Vassart [24].
This calculation procedure has been introduced in the ACB+ software available on
www.arcelormittal.com/sections [23] RFS2-CT-2007-00042 : FICEB+ - Fire resistance of long span cellular beam made of rolled
profiles ; March 2011
[24] O. Vassart, Analytical model for cellular beams made of hot rolled sections in case of fire, PhD Thesis, Université Blaise Pascal Clermont-Ferrand II, 2009
Disciplines :
Civil engineering
Author, co-author :
Vassart, Olivier; ArcelorMittal
Hawes, Mike; ASDWESTOK Ltd
Simms, Ian; Steel Construction Institute
Zhao, Bin; CTICM
Franssen, Jean-Marc ; Université de Liège - ULiège > Département Argenco : Secteur SE > Ingénierie du feu
Nadjai, Ali; Ulster University
Language :
English
Title :
Fire resistance of long span cellular beam made of rolled profiles
Publication date :
March 2011
Publisher :
ArcelorMittal, Esch, Luxembourg
Number of pages :
42
Commissioned by :
Research Programme of the Research Fund for Coal and Steel - Steel RTD
Name of the research project :
FICEB+ - Grant Agreement: RFS2-CT-2007-00042
Funders :
RFCS - European Commission. Research Fund for Coal and Steel