Article (Scientific journals)
Validation of a liquid chromatographic-tandem mass spectrometric method for the determination of loperamide in human plasma
Streel, B.; Ceccato, Attilio; Klinkenberg, R. et al.
2005In Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, 814 (2), p. 263-273
Peer Reviewed verified by ORBi
 

Files


Full Text
articleBSatropine_2005.pdf
Publisher postprint (570.25 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
loperamide; pharmacokinetics; validation
Abstract :
[en] A sensitive and selective method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the quantitative determination of loperamide in human plasma. Automated solid-phase extraction (SPE) on disposable extraction cartridges (DEC) is used to isolate the compounds from the biological matrix and to prepare a cleaner sample before injection and analysis in the LC-MS/MS system. After conditioning, the plasma sample is loaded on the DEC filled with endcapped ethyl silica (C2(EC)) and washed twice with water. The analytes are therefore eluted by dispensing methanol. The eluate is then collected and added with ammonium acetate solution in order to inject an aliquot of this final extract in the LC-MS/MS system. On-line LC-MS/MS system using atmospheric pressure chemical ionization (APCI) has been developed for the determination of loperamide. The separation is obtained on a octadecylsilica based stationary phase using a mobile phase consisting in a mixture of methanol and 5 mM ammonium acetate solution (25:75, v/v). Clonazepam is used as internal standard (IS). The MS/MS ion transitions monitored are m/z 477 --> 266 and 316 --> 270 for loperamide and clonazepam, respectively. The most appropriate regression model of the response function as well as the limit of quantitation were first selected during the pre-validation step. These latter criteria were then assessed during the formal validation step. The limit of quantitation (LOQ) was around 50 pg/ml for loperamide. The method was also validated with respect to recovery, precision, trueness, accuracy and linearity. (C) 2004 Elsevier B.V. All rights reserved.
Disciplines :
Chemistry
Biochemistry, biophysics & molecular biology
Author, co-author :
Streel, B.
Ceccato, Attilio ;  Université de Liège - ULiège > Département de pharmacie > Analyse des médicaments
Klinkenberg, R.
Hubert, Philippe  ;  Université de Liège - ULiège > Chimie analytique
Language :
English
Title :
Validation of a liquid chromatographic-tandem mass spectrometric method for the determination of loperamide in human plasma
Publication date :
25 January 2005
Journal title :
Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences
ISSN :
1570-0232
eISSN :
1873-376X
Publisher :
Elsevier Science Bv, Amsterdam, Netherlands
Volume :
814
Issue :
2
Pages :
263-273
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 16 March 2009

Statistics


Number of views
115 (5 by ULiège)
Number of downloads
7 (2 by ULiège)

Scopus citations®
 
27
Scopus citations®
without self-citations
22
OpenCitations
 
25

Bibliography


Similar publications



Contact ORBi