Article (Scientific journals)
Rapid Screening of Aldehydes by SICRIT-HRMS: Understanding Ionization Behavior in Breath Analysis.
Massenet, Thibault; Abuhelal, Shahd; Rastegar, Leila et al.
2026 • In ACS measurement science au, 6 (5), p. 1537 - 1548
Peer reviewed
 

Files


Full Text
acsmeasuresciau.6c00102 (1).pdf
Publisher postprint (4.79 MB) Creative Commons License - Attribution, Non-Commercial, No Derivative
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Cyclic Ion Mobility; Online Exhaled Breath Analysis; Respiratory Disease Monitoring; SICRIT Ionization; Volatile Aldehydes; Analytical Chemistry; Spectroscopy; Electrochemistry
Abstract :
[en] Exhaled breath aldehydes represent clinically relevant biomarkers of oxidative stress and lipid peroxidation, yet their reliable online detection remains analytically challenging due to their trace concentrations, chemical reactivity, and structural similarity. This study highlights Soft Ionization by Chemical Reaction in Transfer coupled to high-resolution cyclic ion mobility mass spectrometry (SICRIT-cIMS-HRMS) for the direct detection and characterization of 16 clinically relevant volatile aldehydes in exhaled breath. A controlled offline spiking methodology using Tedlar sampling bags was developed, enabling systematic investigation of ionization behavior under realistic breath matrix conditions. Comparative analysis in ultrapure nitrogen and exhaled breath matrices revealed that SICRIT preferentially generates protonated [M+H]+, dehydrated [M+H-H2O]+, and oxidation-derived species, with exhaled breath shifting ionization patterns toward oxygen-containing adducts. Ionization competition from N,N-dimethylacetamide, a Tedlar bag contaminant, was identified and mitigated through standardized bag usage protocols. Quantitative assessment demonstrated good linearity (R2 ≥ 0.99 for 13 aldehydes), with LOD values ranging from 1.33 to 25.13 ppbv. Intraday variability was low across all adducts (CV < 11%), while interday variability was significantly lower for [M+H]+ species (CV < 13%) compared to oxidation-derived adducts, establishing protonated ions as the preferred targets for long-term biomarker monitoring. Cyclic ion mobility separation was evaluated for isomer differentiation. Although tentative separation of 2-ethylhexanal and octanal was observed, sensitivity losses approaching 3 orders of magnitude were encountered, likely attributed to instrument geometry and traveling wave-based ion transmission. Nevertheless, the demonstrated ability of ion mobility to discriminate VOCs from chemical noise and isobaric interferences is encouraging for future developments. This work establishes a fundamental understanding of SICRIT ionization mechanisms in complex breath matrices and identifies key analytical parameters for future method development, validation, and clinical implementation, notably motivating the investigation of SICRIT ionization mechanisms and the use of linear mobility systems for improved aldehyde isomer discrimination in respiratory disease monitoring.
Disciplines :
Chemistry
Author, co-author :
Massenet, Thibault  ;  Université de Liège - ULiège > Molecular Systems (MolSys)
Abuhelal, Shahd;  National Heart and Lung Institute (NHLI), Imperial NIHR Respiratory Biomedical Research Centre, Imperial College London, London W12 0NN, U.K
Rastegar, Leila;  National Heart and Lung Institute (NHLI), Imperial NIHR Respiratory Biomedical Research Centre, Imperial College London, London W12 0NN, U.K
Rai, Amar ;  Faculty of Medicine, Department of Metabolism, Digestion and Reproduction, Imperial College London, London W12 0NN, U.K
Toumazi, Sopika;  National Heart and Lung Institute (NHLI), Imperial NIHR Respiratory Biomedical Research Centre, Imperial College London, London W12 0NN, U.K
Focant, Jean-François  ;  Université de Liège - ULiège > Molecular Systems (MolSys)
Takats, Zoltan ;  Faculty of Medicine, Department of Metabolism, Digestion and Reproduction, Imperial College London, London W12 0NN, U.K
Siddiqui, Salman;  National Heart and Lung Institute (NHLI), Imperial NIHR Respiratory Biomedical Research Centre, Imperial College London, London W12 0NN, U.K
Stefanuto, Pierre-Hugues  ;  Université de Liège - ULiège > Molecular Systems (MolSys)
Language :
English
Title :
Rapid Screening of Aldehydes by SICRIT-HRMS: Understanding Ionization Behavior in Breath Analysis.
Publication date :
21 October 2026
Journal title :
ACS measurement science au
ISSN :
2694-250X
eISSN :
2694-250X
Publisher :
American Chemical Society, United States
Volume :
6
Issue :
5
Pages :
1537 - 1548
Peer reviewed :
Peer reviewed
Funders :
Fondation Leon Fredericq, WBI international, and the FRS-FNRS Inflabreath project
UK Medical Research Council Mid-Range Equipment Grant
University of Dundee and NIHR Imperial, Biomedical Research Centre
Available on ORBi :
since 20 November 2026

Statistics


Number of views
13 (0 by ULiège)
Number of downloads
10 (0 by ULiège)

Scopus citations®
 
0
Scopus citations®
without self-citations
0
OpenAlex citations
 
0

Bibliography


Similar publications



Contact ORBi