Abstract :
[en] Residential decarbonization requires renovation pathways that combine heating
electrification, on-site renewable generation, and energy storage, yet their performance
is commonly assessed using annual energy and carbon indicators that neglect the
timing of grid interactions. This study evaluates five progressive renovations.
configurations for a representative Belgian semi-detached dwelling: a gas-boiler base
case, heat-pump electrification, heat pump with rooftop photovoltaics (PV), and PV
systems combined with 2 and 5 kWh battery storage. The benchmark dwelling was
selected from 708 audited households and calibrated against four years of measured
electricity and gas consumption, achieving monthly ASHRAE Guideline 14 criteria for
both carriers. Operational carbon was evaluated using both the annual-average and
measured hourly Belgian grid emission factors. Replacing the gas boiler with a
reversible heat pump reduced gross delivered energy from 102.2 to 48.5 kWh/(m2·a)
and dynamic operational carbon from 18.46 to 6.14 kgCO2e/(m2·a). Adding PV and
progressively larger batteries further reduced grid imports from 40.0 to 33.2
kWh/(m2·a) and dynamic operational carbon to 4.64 kgCO2e/(m2·a), corresponding to
a 75% reduction relative to the base case. However, annual indicators increasingly
failed to represent these improvements. Net annual energy use remained identical at
31.7 kWh/(m2·a) across all three PV configurations despite substantial reductions in
grid imports and carbon emissions. Moreover, the discrepancy between annualaverage
and hourly carbon accounting increased from 3.0% for the base case to
30.3% for the heat-pump, PV, and 5 kWh battery configuration. This widening temporal
carbon performance gap results from residual-import carbon intensification, as PV
preferentially displaces cleaner midday electricity while remaining imports become
concentrated in carbon-intensive winter and evening periods. The findings demonstrate
that effective residential renovation assessment should evaluate not only annual
energy reductions but also the timing and carbon intensity of grid interactions,
particularly as buildings transition toward electrification, distributed generation, and
storage.