Corrigendum to "Gas chromatography-trapped ion mobility mass spectrometry: A highly specific and ultra-sensitive platform for quantifying sub-ppt levels of dioxins and PCBs in food" [Chemosphere 385, 2025, 144557]. - 2025
Corrigendum to "Gas chromatography-trapped ion mobility mass spectrometry: A highly specific and ultra-sensitive platform for quantifying sub-ppt levels of dioxins and PCBs in food" [Chemosphere 385, 2025, 144557].
Dioxins; EU Regulation 2017/644; Food and Feed; Gas chromatography; Ion mobility; PCBs; POPs; TIMS; Validation
Abstract :
[en] In this study, we evaluated the quantitative capabilities of a GC-APCI trapped ion mobility (TIMS) TOF platform for the determination of ultra-trace levels of polychlorinated dibenzo-p-dioxins (PCDD/Fs) and polychlorinated biphenyls (PCBs) in complex food matrices. Using a Bruker timsTOF Pro 2 instrument, three fat-based proficiency test samples - fish oil, palm oil, and milk fat - were analyzed and compared to a validated GC-sectorHRMS method, in accordance with the criteria set by Commission Regulation (EU) 2017/644. Linearity was confirmed across broad dynamic ranges, with relative response factor (RRF) precision consistently below 20 %. Instrumental limits of quantification (iLOQs) reached the 100-500 fg/μL range for dioxins and low pg/μL for PCBs, while method LOQs (mLOQs) were typically in the high fg/g to low pg/g range. Intermediate precision (RSDR) remained below regulatory thresholds in 97 % of cases. Furthermore, 80 % of PCDD/Fs and over 87 % of PCB measurements met trueness requirements, with summed WHO2005-TEQ and NDL-PCB concentrations in close agreement with sectorHRMS values. Importantly, the addition of the ion mobility dimension provided distinct benefits. It enabled the separation of coeluting isomers (e.g., 2,3,7,8-TCDD), resolved isobaric interferences (e.g., PeCDD and HxCB 169), and allowed for high-confidence analyte identification using collision cross section (CCS) values. CCS differences between native and 13C-labeled standards were consistently below 0.5 %, supporting its use as an additional identification criterion. Overall, while the method showed slightly reduced performance for ultra-trace dioxins, it demonstrated accurate quantification and enhanced selectivity, highlighting the strong potential of TIMS-TOF technology for contaminant analysis in food safety applications.
Disciplines :
Chemistry
Author, co-author :
Muller, Hugo ; Université de Liège - ULiège > Département de chimie (sciences) > Chimie analytique inorganique
Scholl, Georges ; Université de Liège - ULiège > Département de chimie (sciences) > Center for Analytical Research and Technology (CART)
Eppe, Gauthier ; Université de Liège - ULiège > Département de chimie (sciences) > Laboratoire de spectrométrie de masse (L.S.M.)
Language :
English
Title :
Corrigendum to "Gas chromatography-trapped ion mobility mass spectrometry: A highly specific and ultra-sensitive platform for quantifying sub-ppt levels of dioxins and PCBs in food" [Chemosphere 385, 2025, 144557].
Alternative titles :
[en] Corrigendum to “Gas chromatography–trapped ion mobility mass spectrometry: A highly specific and ultra-sensitive platform for quantifying sub-ppt levels of dioxins and PCBs in food” [Chemosphere 385, 2025, 144557] (Chemosphere (2025) 385, (S0045653525005016), (10.1016/j.chemosphere.2025.144557))
FWB - Fédération Wallonie-Bruxelles FRIA - Fonds pour la Formation à la Recherche dans l'Industrie et dans l'Agriculture FOD Volksgezondheid - Federale Overheidsdienst Volksgezondheid - Veiligheid van de Voetselketen en Leefmilieu
Funding text :
This work was supported by the French Community of Belgium through the funding of a FRIA grant (FC 47331) and the Belgian Federal Public Service of Health, Food Chain Safety and Environment (RT22/06 TEQFOOD). The authors thank Bruker Applied Mass Spectrometry (BAMS) for their support and the European Reference Laboratory for Halogenated Persistent Organic Pollutants in Feed and Food (EURL POPs, Freiburg, Germany) for kindly provinding the PT samples.