Unpublished conference/Abstract (Scientific congresses and symposiums)
Advanced metabolomic profiling of exhaled breath condensate via GC×GC-MS and multi-block data fusion
Passos de Resende, Glaucimar Alex; Massenet, Thibault; Schyns, Joey et al.
2026 • 20th edition of the Chemometrics in Analytical Chemistry (CAC-2026)
Peer reviewed
 

Files


Full Text
OC16-CAC 2026_GlaucimarResende.pdf
Author postprint (4.65 MB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] Exhaled breath condensate (EBC) is a non-invasive and chemically rich matrix for respiratory analysis, with significant applications in biomarker discovery and disease diagnosis [1]. In breathomics, the high dimensionality and complexity of the matrix require robust analytical platforms, such as comprehensive two-dimensional gas chromatography coupled to mass spectrometry (GC×GC-MS), alongside sophisticated chemometric workflows to ensure accurate metabolite attribution [2,3]. This study aims to optimize the representation of EBC metabolites using GC×GC-MS combined with data fusion strategies. Samples from 12 patients with various respiratory diseases were analysed to evaluate the efficiency of different detection methodologies. The experimental workflow involved volatile organic compound (VOC) profiling via derivatization (methoximation and trimethylsilylation) and lipidomic profiling following microwave-assisted sample preparation. To ensure a representative optimization, individual samples were pooled into a single matrix for initial characterization. Methodological optimization was performed using a Design of Experiments (DoE) approach: a Plackett Burman design for factor screening, followed by a Box-Behnken design to determine optimal conditions via the desirability function. Low-level and high-level data fusion models were constructed to integrate the derivatization and lipidomic datasets. Data preprocessing included baseline correction, smoothing, and mean centering following icoshift alignment. For the pixel-based strategy, Principal Component Analysis (PCA) was the primary tool used to evaluate the information gained from individual versus fused datasets. Results indicate that while individual methodologies provide specific chemical insights, the data fusion approach successfully captured the heterogeneous nature of the samples, providing a more holistic metabolic signature. This study demonstrates the necessity of integrated chemometric workflows in respiratory research and provides a framework for future diagnostic applications in specific respiratory disorders.
Disciplines :
Chemistry
Author, co-author :
Passos de Resende, Glaucimar Alex  ;  Université de Liège - ULiège > Molecular Systems (MolSys)
Massenet, Thibault  ;  Université de Liège - ULiège > Molecular Systems (MolSys)
Schyns, Joey  ;  Université de Liège - ULiège > Département des sciences cliniques > Pneumologie - Allergologie
Guiot, Julien  ;  Université de Liège - ULiège > Département des sciences cliniques > Pneumologie - Allergologie
Focant, Jean-François  ;  Université de Liège - ULiège > Département de chimie (sciences) > Chimie analytique, organique et biologique
Stefanuto, Pierre-Hugues  ;  Université de Liège - ULiège > Département de chimie (sciences)
Language :
English
Title :
Advanced metabolomic profiling of exhaled breath condensate via GC×GC-MS and multi-block data fusion
Publication date :
01 July 2026
Event name :
20th edition of the Chemometrics in Analytical Chemistry (CAC-2026)
Event date :
from June 29 to July 3, 2026
Audience :
International
Peer review/Selection committee :
Peer reviewed
Funders :
F.R.S.-FNRS - Fonds de la Recherche Scientifique
Funding text :
This work is supported by FRS-FNRS HyVOCs PDR project. We would like to thank LECO Corporation for their support.
Available on ORBi :
since 14 August 2026

Statistics


Number of views
91 (6 by ULiège)
Number of downloads
1 (1 by ULiège)

Bibliography


Similar publications



Contact ORBi