Article (Scientific journals)
Incidence and features of pulmonary track nodules after CT-guided lung biopsy with track sealing using gelatin sponge slurry.
Grandjean, Flavien; Withofs, Nadia; Detrembleur, Nancy et al.
2025In BMC Medical Imaging, 25 (1), p. 107
Peer Reviewed verified by ORBi
 

Files


Full Text
12880_2025_Article_1644.pdf
Publisher postprint (1.72 MB) Creative Commons License - Attribution, Non-Commercial, No Derivative
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
CT-guided lung biopsy; Gelatin sponge; Pneumothorax; Track sealant; Gelatin; Humans; Female; Male; Middle Aged; Retrospective Studies; Aged; Adult; Lung/pathology; Lung/diagnostic imaging; Incidence; Aged, 80 and over; Tomography, X-Ray Computed/methods; Pneumothorax/prevention & control; Pneumothorax/etiology; Image-Guided Biopsy/adverse effects; Image-Guided Biopsy/methods; Lung Neoplasms/diagnostic imaging; Lung Neoplasms/pathology; Solitary Pulmonary Nodule/diagnostic imaging; Solitary Pulmonary Nodule/epidemiology; Solitary Pulmonary Nodule/pathology; Image-Guided Biopsy; Lung; Lung Neoplasms; Solitary Pulmonary Nodule; Tomography, X-Ray Computed; Radiology, Nuclear Medicine and Imaging
Abstract :
[en] [en] BACKGROUND: Track sealing (TS) with gelatin sponge slurry (GSS) is efficient in reducing pneumothorax after CT-guided lung biopsy. Nodule appearance along the pulmonary track after TS with GSS is a potential issue that has not been previously evaluated. METHODS: A secondary analysis of two studies evaluating the efficacy of lung TS in 710 patients in reducing post-biopsy pneumothorax was performed. Among these patients, 377 had a follow-up CT within 2 months post-biopsy and were retrospectively included in this study (187 had TS with GSS, 83 with saline, and 107 no TS). Imaging findings of the pulmonary track were described. Binary logistic regression was used to determine factors associated with lung track nodules. RESULTS: Median time between biopsy and follow-up CT was 29 days (range, 1-61). A pulmonary track nodule was detected on follow-up CT in 65/377 (17.2%) patients. Sixty three out of these 65 nodules (97%) were observed in the GSS group. Factors significantly associated with nodules on multivariate analysis were GSS use (odds ratio: 47.4, 95%CI:11.8-189.5; p < .0001) and track length (odds ratio: 1.03, 95%CI:1.01-1.05; p = .009). Nodules were solid in 100%, ovoid in 83.1%, well-defined in 87.7%, and had smooth borders in 96.9%. Thirty-three nodules were still visible on imaging > 6 weeks after the biopsy. CONCLUSION: A pulmonary nodule along the biopsy track was detected on follow-up CT in 34% of cases when TS with GSS was performed. Recognition of these nodules on chest imaging is essential to avoid misinterpretation. CLINICAL TRIAL NUMBER: Not applicable.
Disciplines :
Radiology, nuclear medicine & imaging
Author, co-author :
Grandjean, Flavien  ;  Centre Hospitalier Universitaire de Liège - CHU > > Service médical de radiodiagnostic
Withofs, Nadia  ;  Université de Liège - ULiège > GIGA > GIGA Platforms - In Vivo Imaging - Nuclear Medicine Division
Detrembleur, Nancy ;  Université de Liège - ULiège > Département des sciences biomédicales et précliniques
GERARD, Laurent ;  Centre Hospitalier Universitaire de Liège - CHU > > Service médical de radiodiagnostic
Lamborelle, Pierre;  Department of Imaging, University Hospital of Liège, Avenue de l'Hôpital 1, Liège, 4000, Belgium
VALKENBORGH, Christophe ;  Centre Hospitalier Universitaire de Liège - CHU > > Service médical de radiodiagnostic
Dardenne, Nadia  ;  Université de Liège - ULiège > Département des sciences de la santé publique
Cousin, François  ;  Université de Liège - ULiège > Département des sciences cliniques
Language :
English
Title :
Incidence and features of pulmonary track nodules after CT-guided lung biopsy with track sealing using gelatin sponge slurry.
Publication date :
02 April 2025
Journal title :
BMC Medical Imaging
eISSN :
1471-2342
Publisher :
BioMed Central Ltd, England
Volume :
25
Issue :
1
Pages :
107
Peer reviewed :
Peer Reviewed verified by ORBi