[en] In contrast to a recent study reporting an unexpected significant difference for total 25-hydroxyvitamin D (25(OH)D) between serum and EDTA plasma, we demonstrate that concentrations of total 25(OH)D, 25(OH)D2, 25(OH)D3 and 24,25(OH)2D3 do not differ between matched serum and EDTA plasma samples, using two well-characterized LC-MS/MS methods.
Disciplines :
Laboratory medicine & medical technology
Author, co-author :
van der Vorm, Lisa N; Department of Clinical Chemistry, Central Diagnostic Laboratory, Amsterdam University Medical Center, Amsterdam, the Netherlands
Le Goff, Caroline ; Centre Hospitalier Universitaire de Liège - CHU > > Service de chimie clinique
PEETERS, Stéphanie ; Centre Hospitalier Universitaire de Liège - CHU > > Service de chimie clinique
Makris, Konstantinos; Clinical Biochemistry Department, KAT General Hospital, Athens, Greece, Laboratory for Research of the Musculoskeletal System "Th. Garofalidis", Medical School, University of Athens, Athens, Greece
Cavalier, Etienne ; Centre Hospitalier Universitaire de Liège - CHU > > Service de chimie clinique
Heijboer, Annemieke C; Department of Clinical Chemistry, Endocrine Laboratory, Amsterdam Gastroenterology Endocrinology & Metabolism, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands. Electronic address: a.heijboer@amsterdamumc.nl
Language :
English
Title :
25-OH Vitamin D concentrations measured by LC-MS/MS are equivalent in serum and EDTA plasma.
Abu Kassim, N.S., Gomes, F.P., Shaw, P.N., Hewavitharana, A.K., Simultaneous quantitative analysis of nine vitamin D compounds in human blood using LC-MS/MS. Bioanalysis. 8:5 (2016), 397–411.
Mena-Bravo, A., Priego-Capote, F., Luque de Castro, M.D., Study of blood collection and sample preparation for analysis of vitamin D and its metabolites by liquid chromatography-tandem mass spectrometry. Anal. Chim. Acta. 879 (2015), 69–76.
Harvey, S.M., Murphy, V.E., Gibson, P.G., Clarke, M., Jensen, M.E., The Impact of Sample Type on Vitamin D Quantification and Clinical Classification during Pregnancy. Nutrients., 12(12), 2020, 3872.
Elsenberg, E.H.A.M., ten Boekel, E., Huijgen, H., Heijboer, A.C., Standardization of automated 25-hydroxyvitamin D assays: How successful is it?. Clin. Biochem. 50:18 (2017), 1126–1130.
Fabregat-Cabello, N., Farre-Segura, J., Huyghebaert, L., Peeters, S., Le Goff, C., Souberbielle, J.-C., Cavalier, É., A fast and simple method for simultaneous measurements of 25(OH)D, 24,25(OH)2D and the Vitamin D Metabolite Ratio (VMR) in serum samples by LC-MS/MS. Clin. Chim. Acta. 473 (2017), 116–123.