[en] This article presents the validation results of a chiral liquid chromatographic (LC) method previously developed for the quantitative determination of R-timolol in S-timolol maleate samples. A novel validation strategy based on the accuracy profiles was used to select the most appropriate regression model, to assess the method accuracy within well defined acceptance limits and to determine the limits of quantitation as well as the concentration range. The validation phase was completed by the investigation of the risk profiles of various acceptable regression models in order to ensure the risk of obtaining the future measurements outside the acceptance limits fixed a priori. On the other hand, the present paper also shows how data used in this validation approach can be used to estimate the measurement uncertainty. The uncertainty derived from beta-expectation tolerance interval (sigma(Tol)(2)), which is equal to the uncertainty of measurements as well as the expanded uncertainty (U(x)) using a coverage factor k=2 was estimated. The uncertainty estimates obtained from validation data were finally compared with those obtained from interlaboratory and robustness studies.
(1995) Food and Drug Administration: International Conference on Harmonization, Definitions and Terminology, Fed. Regist., 60, p. 11260
Food and Drug Administration: International Conference on Harmonization, Methodology (1997) Fed. Regist., 62, p. 27463
Caporal-Gauthier, J., Nivet, J.M., Algranti, P., Guilloteau, M., Histe, M., Lallier, M., N'Guyen-Huu, J.J., Russoto, R., (1992) S.T.P. Pharma Pratiques, 2 (4), p. 205
Chapuzet, E., Mercier, N., Bervoas-Martin, S., Boulanger, B., Chevalier, P., Chiap, P., Granjean, D., Nivet, J.C., (1997) S.T.P. Pharma Pratiques, 7 (3), p. 169
Boulanger, B., Chiap, P., Dewé, W., Crommen, J., Hubert, Ph., (2003) J. Pharm. Biomed. Anal., 32, p. 753
Box, G.E.P., Behnken, D.W., (1960) Technometrics, 2, p. 455
Dewe, W., Marini, R.D., Chiap, P., Hubert, Ph., Crommen, J., Boulanger, B., (2004) Chemom. Intell. Lab. Syst., 74, p. 263
(1994) Application of the Statistics - Accuracy (Trueness and Precision) of the Results and Methods of Measurement. Part 1: General Principles and Definitions, , ISO 5725-1 International Organization for Standardization (ISO), Geneva
(2004) European Pharmacopoeia, , fifth ed. Council of Europe Strasbourg, France