Article (Scientific journals)
Comparison of five radioimmunoassay systems for PAG measurement: Ability to detect early pregnancy in cows
Ayad, A.; Melo de Sousa, Noelita; Sulon, Joseph et al.
2007In Reproduction in Domestic Animals, 42 (4), p. 433-440
Peer Reviewed verified by ORBi
 

Files


Full Text
AyadA-ReprodDomAnim-2007.pdf
Publisher postprint (524.74 kB)
Demander un tiré à part
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
radioimmunoassay; pregnancy; cows
Abstract :
[en] This study was conducted to describe the minimum detection limit, reproducibility, accuracy, specificity and parallelism of different pregnancy-associated glycoprotein radioimmunoassay (PAG-RIA) systems: RIA-497, RIA-706, RIA-780, RIA-809 and RIA-Pool. Their ability to distinguish between non-pregnant and pregnant females at day 30 after artificial insemination (Al) was investigated. The antisera were raised in rabbits against different PAG preparations. All RIA systems proved to be sensitive, repeatable and accurate for measuring PAG concentrations. The dilutions of plasma samples taken at an early stage of pregnancy were found to be parallel to the standard curves. No cross-reaction was observed with different carbohydrates, either with Pregnant Marc Serum Gonadotropin (PMSG) or human Chorionic Gonadotropin (hCG). The concentrations of PAG in pregnant females at day 30 after Al were shown to be higher with the use of antisera R#706, R#780, R#809 and Pool when compared with antiserum R#497. All the RIA systems gave 100% sensitivity and negative predictive values. On the other hand, the use of antisera R#780 and R#809 resulted in lower specificity and positive predictive values. The present study clearly shows that the ability of PAG-RIA systems to diagnose pregnancy specifically at day 30 after Al can be improved by using a combination of antisera raised against different forms of PAG.
Disciplines :
Veterinary medicine & animal health
Author, co-author :
Ayad, A.;  Université de Liège - ULiège > Faculty of veterinary medicine
Melo de Sousa, Noelita ;  Université de Liège - ULiège > Département de sciences fonctionnelles > Physiologie de la reproduction
Sulon, Joseph ;  Université de Liège - ULiège > Département de sciences fonctionnelles > Physiologie de la reproduction
Iguer-Ouada, M.;  University Abderahmane Mira, Bejaia, Algeria > Organism and Populations Biology, Faculty of Life and Nature Sciences
Beckers, Jean-François  ;  Université de Liège - ULiège > Département de sciences fonctionnelles > Physiologie de la reproduction
Language :
English
Title :
Comparison of five radioimmunoassay systems for PAG measurement: Ability to detect early pregnancy in cows
Publication date :
2007
Journal title :
Reproduction in Domestic Animals
ISSN :
0936-6768
eISSN :
1439-0531
Publisher :
Blackwell Publishing, Berlin, Germany
Volume :
42
Issue :
4
Pages :
433-440
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 07 March 2009

Statistics


Number of views
59 (3 by ULiège)
Number of downloads
0 (0 by ULiège)

Scopus citations®
 
17
Scopus citations®
without self-citations
4
OpenCitations
 
14

Bibliography


Similar publications



Contact ORBi