Article (Scientific journals)
Influence of controlled immediate loading and implant design on peri-implant bone formation.
Vandamme, Katleen; Naert, Ignace; Geris, Liesbet et al.
2007In Journal of Clinical Periodontology, 34 (2), p. 172-81
Peer Reviewed verified by ORBi
 

Files


Full Text
JCP_2007.pdf
Publisher postprint (2.93 MB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Animals; Calcification, Physiologic/physiology; Dental Implantation, Endosseous/methods; Dental Implants; Dental Prosthesis Design; Dental Stress Analysis; Female; Models, Animal; Osseointegration/physiology; Rabbits; Stress, Mechanical; Tibia; Weight-Bearing
Abstract :
[en] AIM: Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. MATERIAL AND METHODS: A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. RESULTS: A significantly higher bone area fraction was observed for SL compared with SU (p<0.0001). The mineralized bone fraction was the highest for SL and significantly different from SU (p<0.0001). The chance that osteoid- and bone-to-implant contact occurred was the highest for SL and significantly different from SU (p<0.0001), but not from CL. When bone-to-implant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. CONCLUSIONS: Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.
Disciplines :
Biochemistry, biophysics & molecular biology
Author, co-author :
Vandamme, Katleen;  Department of Prosthetic Dentistry/BIOMAT Research Group, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, K.U.Leuven, Leuven, Belgium
Naert, Ignace;  Department of Prosthetic Dentistry/BIOMAT Research Group, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, K.U.Leuven, Leuven, Belgium
Geris, Liesbet  ;  Université de Liège - ULiège > Département d'aérospatiale et mécanique > Génie biomécanique
Vander Sloten, Jozef;  Division of Biomechanics and Engineering Design, K.U.Leuven, Leuven, Belgium
Puers, Robert;  Department of Electrical Engineering– ESAT-MICAS, K.U.Leuven, Kasteelpark Arenberg, Leuven, Belgium
Duyck, Joke;  Department of Prosthetic Dentistry/BIOMAT Research Group, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, K.U.Leuven, Leuven, Belgium
Language :
English
Title :
Influence of controlled immediate loading and implant design on peri-implant bone formation.
Publication date :
2007
Journal title :
Journal of Clinical Periodontology
ISSN :
0303-6979
eISSN :
1600-051X
Publisher :
Blackwell Publishing
Volume :
34
Issue :
2
Pages :
172-81
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 26 August 2010

Statistics


Number of views
65 (1 by ULiège)
Number of downloads
0 (0 by ULiège)

Scopus citations®
 
59
Scopus citations®
without self-citations
45
OpenCitations
 
47

Bibliography


Similar publications



Contact ORBi