Article (Scientific journals)
Correlation of pelvic magnetic resonance imaging with diagnostic loop electrosurgical excision procedure/cone biopsy and hysterectomy pathology: an exploratory analysis of the CX.5/SHAPE trial.
Plante, Marie; Kwon, Janice S; Mahner, Sven et al.
2026 • In International Journal of Gynecological Cancer, 36 (9), p. 104835
Peer Reviewed verified by ORBi
 

Files


Full Text
2026-IJGC-Cervix-Shape-RMI Correlation-Plante.pdf
Author postprint (2.95 MB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Diagnostic LEEP/Cone; Early-Stage Cervical Cancer; Preoperative Pelvic MRI; Humans; Female; Hysterectomy/methods; Middle Aged; Adult; Conization/methods; Magnetic Resonance Imaging/methods; Electrosurgery/methods; Uterine Cervical Neoplasms/pathology; Uterine Cervical Neoplasms/surgery; Uterine Cervical Neoplasms/diagnostic imaging; Conization; Electrosurgery; Hysterectomy; Magnetic Resonance Imaging; Uterine Cervical Neoplasms; Oncology; Obstetrics and Gynecology
Abstract :
[en] [en] OBJECTIVE: To evaluate the concordance between preoperative loop electrosurgical excision procedure (LEEP)/cone margins, pelvic magnetic resonance imaging, and final pathology from the hysterectomy specimen in the CX.5/SHAPE trial. METHODS: This exploratory analysis included patients who underwent preoperative LEEP/cone biopsy and pelvic magnetic resonance imaging prior to hysterectomy. Primary outcomes included the correlation between pelvic magnetic resonance imaging and final pathology: (1) "undercall" (no disease on magnetic resonance imaging but disease on final pathology); (2) "overcall" (disease on magnetic resonance imaging but none on final pathology), and (3) "concordance" (disease or no disease on both magnetic resonance imaging and final pathology), Oncologic outcomes were evaluated according to the 3 magnetic resonance imaging groups. Magnetic resonance imaging sequences included T1 and high-resolution T2, and diffusion-weighted imaging; the use of gadolinium was not mandatory. RESULTS: A total of 480 patients had a pelvic magnetic resonance imaging performed after a diagnostic LEEP/cone procedure. The magnetic resonance imaging undercall rate was 27.1% (95% confidence interval 23.2% to 31.3%), the overcall rate 8.5% (95% confidence interval 6.2% to 11.4%), and concordance rate 64.4% (95% confidence interval 59.5% to 68.7%) with sensitivity of 30.5% (95% confidence interval 24.0 to 37.6) and specificity of 86.0% (95% confidence interval 81.5 to 90.0) for residual disease. Higher magnetic resonance imaging concordance was associated with negative versus positive LEEP/cone margins (76.6% vs 57.3%, p < .0001). Adenocarcinoma was associated with a lower positive predictive value (41.9%) compared to squamous (66.2%) and adenosquamous (50%) (p = .04). Overall, 10 patients had no disease on preoperative magnetic resonance imaging and tumors greater >2 cm on final pathology (undercall); 6 had simple hysterectomy (under-treatment). Conversely, 41 patients had disease on preoperative magnetic resonance imaging and no residual disease on final pathology (overcall); 20 had radical hysterectomy (over-treatment). There were no differences in pelvic recurrences (p = .09) or deaths (p = .16) between magnetic resonance imaging correlation groups. Positive LEEP/cone margins and residual disease on magnetic resonance imaging were associated with more adjuvant treatment (13.0%) compared with negative margins and no disease on magnetic resonance imaging (2.5%). CONCLUSIONS: There was modest concordance between preoperative magnetic resonance imaging following LEEP/Cone procedure and final hysterectomy pathology in the SHAPE trial, but there was limited impact on rates of under- and over-treatment.
Disciplines :
Reproductive medicine (gynecology, andrology, obstetrics)
Oncology
Radiology, nuclear medicine & imaging
Author, co-author :
Plante, Marie ;  Centre Hospitalier Universitaire de Québec, Quebec City, Canada. Electronic address: marie.plante@crhdq.ulaval.ca
Kwon, Janice S ;  University of British Columbia, Vancouver, British Columbia, Canada
Mahner, Sven;  Department of Obstetrics and Gynecology, LMU Hospital, Ludwig Maximilians University of Munich, Munich, Germany
Cormier, Beatrice;  Centre Hospitalier Universitaire de Montréal, Montréal, Canada
Fortin, Suzanne;  Hôpital Maisonneuve-Rosemont, CIUSSS de l'Est de l'Île de Montréal, Montréal, Canada
Theret, Pierrick ;  Centre Hospitalier Universitaire Amiens-Picardie, Amiens, France
Bats, Anne-Sophie;  AP-HP Hôpital Européen Georges Pompidou, Paris, France
de Kroon, Cor ;  Leiden University Medical Center, Leiden, The Netherlands
Van Driel, Willemien ;  NKI-AVL/CGOA, Amsterdam, The Netherlands
Tidy, John ;  Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United Kingdom
Williamson, Karin;  NUH.NHS, Nottingham, United Kingdom
Hillemanns, Peter ;  Hannover Medical School, Hannover, Germany
Goffin, Frédéric ;  Université de Liège - ULiège > Département des sciences cliniques > Gynécologie-obstétrique, partim Gynécologie
Polterauer, Stephan;  Department of Obstetrics and Gynecology, Medical University of Vienna, Vienna, Austria
Eyjolfsdottir, Brynhildur ;  Oslo University Hospital, Radium Hospital, Oslo, Norway
Maguire, Patrick J;  St James's Hospital University Hospital, Dublin, Ireland
Kim, Se Ik ;  Seoul National University College of Medicine, Seoul, Republic of Korea
Atri, Mostafa;  Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
Shepherd, Lois;  Queens' University, Kingston, Canada
Tu, Dongsheng ;  Queens' University, Kingston, Canada
More authors (10 more) Less
Language :
English
Title :
Correlation of pelvic magnetic resonance imaging with diagnostic loop electrosurgical excision procedure/cone biopsy and hysterectomy pathology: an exploratory analysis of the CX.5/SHAPE trial.
Publication date :
September 2026
Journal title :
International Journal of Gynecological Cancer
ISSN :
1048-891X
eISSN :
1525-1438
Publisher :
Elsevier Inc., United States
Volume :
36
Issue :
9
Pages :
104835
Peer reviewed :
Peer Reviewed verified by ORBi
Funding text :
from funding agencies in the public, commercial, or not-for-profit sectors. We would like to acknowledge the support of the Gynecologic Cancer InterGroup, which facilitated the participation of the many international cooperative groups who made the SHAPE trial a success.
Available on ORBi :
since 16 November 2026

Statistics


Number of views
14 (0 by ULiège)
Number of downloads
12 (0 by ULiège)

Scopus citations®
 
0
Scopus citations®
without self-citations
0
OpenAlex citations
 
1

Bibliography


Similar publications



Contact ORBi