Article (Scientific journals)
Kinematics-based model for shear capacity assessment of unreinforced interior beam–column joints
Arcuri, Daniele; Petrini, Lorenza; Mihaylov, Boyan
2026 • In Structural Concrete, 27 (5), p. 8159-8179
Peer Reviewed verified by ORBi
 

Files


Full Text
2026c_Arcuri_Petrini_Mihaylov.pdf
Embargo Until 01/Jan/2027 - Publisher postprint (6.03 MB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
discrete cracks; existing RC buildings; kinematic model; unreinforced interior joints; Civil and Structural Engineering; Building and Construction; Materials Science (all); Mechanics of Materials
Abstract :
[en] This study presents a kinematics-based model for assessing the shear strength of reinforced concrete interior beam–column joints without transverse reinforcement. The proposed framework is built on first principles—kinematics, equilibrium, and constitutive relations—and explicitly models discrete cracks by introducing kinematic parameters such as crack width and crack length. The formulation also accounts for the bond-slip behavior between concrete and reinforcement, providing distinct expressions for deformed and smooth reinforcing bars. The solution is obtained through an iterative procedure suitable for engineering applications, providing accurate predictions when compared to experimental results. The model is validated with 26 test specimens and compared with the joint strength provisions of the Italian Annex of Eurocode. The results show that the proposed approach significantly reduces both the conservatism and scatter of code-based strength predictions, providing an effective and practical tool for accurately assessing the shear strength of interior joints to avoid unnecessary, costly, and disruptive retrofitting interventions.
Disciplines :
Civil engineering
Author, co-author :
Arcuri, Daniele ;  Department of Civil and Environmental Engineering, Politecnico di Milano, Milan, Italy
Petrini, Lorenza;  Department of Civil and Environmental Engineering, Politecnico di Milano, Milan, Italy
Mihaylov, Boyan ;  Université de Liège - ULiège > Urban and Environmental Engineering
Language :
English
Title :
Kinematics-based model for shear capacity assessment of unreinforced interior beam–column joints
Publication date :
2026
Journal title :
Structural Concrete
ISSN :
1464-4177
eISSN :
1751-7648
Publisher :
John Wiley and Sons Inc
Volume :
27
Issue :
5
Pages :
8159-8179
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 15 October 2026

Statistics


Number of views
30 (0 by ULiège)
Number of downloads
0 (0 by ULiège)

Scopus citations®
 
0
Scopus citations®
without self-citations
0
OpenAlex citations
 
0

Bibliography


Similar publications



Contact ORBi