Article (Scientific journals)
Rationale and design of a prospective European multicenter evaluation of the iCover balloon-expandable covered stent as a bridging stent in fenestrated endovascular aortic repair (fenCo).
Ducasse, Eric; Riambau, Vincent; Tsilimparis, Nikolaos et al.
2026 • In Journal of Cardiovascular Surgery
Peer Reviewed verified by ORBi
 

Files


Full Text
présentation FenCo.pdf
Author postprint (953.06 kB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] [en] BACKGROUND: Fenestrated endovascular aortic repair (FEVAR) is an established treatment for complex abdominal aortic aneurysms involving the renovisceral segment. Long-term durability remains dependent on bridging stent performance, yet prospective device-specific data remain limited. The fenCo study was designed to evaluate the clinical performance and safety of the iCover balloon-expandable covered stent (iVascular) used as a bridging stent during FEVAR. METHODS: fenCo is a prospective, multicenter, open-label, single-arm European clinical investigation conducted in 24 high-volume centers under Regulation (EU) 2017/745. The study aims to include 165 patients undergoing FEVAR for juxtarenal, pararenal, suprarenal, or thoracoabdominal aneurysms using an IFU-compliant fenestrated endograft. All target vessels are bridged exclusively using the iCover balloon-expandable covered stent. Follow-up is planned at discharge, 6 months, and 12 months, with optional extension to 5 years. RESULTS: The primary efficacy endpoint is bridging-stent patency at 12 months, defined as absence of binary restenosis (≥50% stenosis) or occlusion on imaging. The primary safety endpoint is freedom from target vessel instability, defined as a composite of aneurysm rupture, target vessel occlusion, component separation, branch-related endoleak, or branch-related reintervention. Secondary endpoints include technical success, endoleaks, reinterventions, mortality, aneurysm sac evolution, and renal outcomes. CONCLUSIONS: fenCo will provide prospective multicenter European data on the safety and performance of the iCover stent used as a bridging stent during FEVAR using predefined imaging-based and clinically adjudicated endpoints. The study is expected to strengthen the evidence base for bridging stent selection in complex endovascular aortic repair.
Disciplines :
Surgery
Author, co-author :
Ducasse, Eric;  Department of Vascular Surgery, CHU de Bordeaux, Bordeaux, France
Riambau, Vincent;  Department of Vascular Surgery, Hospital Clinic of Barcelona, Barcelona, Spain
Tsilimparis, Nikolaos;  Department of Vascular Surgery, LMU Klinikum - Campus Großhadern, Munich, Germany
De Vries, Jean-Paul;  Department of Vascular Surgery, University Medical Center Groningen, Groningen, the Netherlands
Lansink, Wouter;  Department of Vascular Surgery, Ziekenhuis Oost-Limburg (ZOL), Genk, Belgium
Caradu, Caroline;  Department of Vascular Surgery, CHU de Bordeaux, Bordeaux, France - caroline.caradu@chu-bordeaux.fr
fenCo Investigators
Kerzmann, Arnaud  ;  Centre Hospitalier Universitaire de Liège - CHU > > Service de chirurgie cardio-vasculaire et thoracique
Language :
English
Title :
Rationale and design of a prospective European multicenter evaluation of the iCover balloon-expandable covered stent as a bridging stent in fenestrated endovascular aortic repair (fenCo).
Publication date :
03 August 2026
Journal title :
Journal of Cardiovascular Surgery
ISSN :
0021-9509
eISSN :
1827-191X
Publisher :
Edizioni Minerva Medica, Italy
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 06 September 2026

Statistics


Number of views
33 (1 by ULiège)
Number of downloads
26 (0 by ULiège)

OpenAlex citations
 
0

Bibliography


Similar publications



Contact ORBi