Combining per-aqueous and chiral reversed phase separation modes towards an enhanced comprehensive 2-dimensional liquid chromatographic based chiral screening platform.
Rahmani, Turaj; Bandini, Elena; Schuster, Stephanie Aet al.
2025 • In Journal of Chromatography. A, 1748, p. 465875
[en] The differentiation of enantiomers in complex mixtures is crucial in various fields such as food science, pharmaceuticals, and environmental studies. While this is achievable in principle through comprehensive two-dimensional liquid chromatography (LC × LC), practical challenges emerge when the mobile phase used in the first dimension (1D) is too strong or incompatible with the one in the second dimension (2D), leading to peak broadening and reduced resolution. These drawbacks become particularly evident when analyzing a diverse range of chiral compounds. In order to obtain timely elution of such compounds, typically spanning a range of hydrophobicity, the use of gradients (in both dimensions) is inevitable. This in turn leads to changing mobile phase compositions transferred from 1D to 2D, and hence to variations in the effectiveness of the modulation process. Lowering of the eluotropic strength of the mobile phase used in 1D allows to mitigate such problems. In this study, a novel achiral × chiral platform for fully automated screening of chiral compounds was developed. In the 1D of this platform, reversed HILIC (or per-aqueous liquid chromatography (PALC)) was employed, utilizing a commercially available HILIC column, which ensures robust and reproducible results with a water-rich mobile phase. In 2D, chiral chromatography with a broad range of gradients was utilized. Moreover, the impact of varying concentrations of organic solvent transferred to the 2D on enantioseparation was investigated. The water-rich mobile phase in the 1D facilitates the complete refocusing of organic solutes before entering the second dimension, preventing the loss of resolution in the 2D. This also allows for longer sampling times, consequently longer 2D running times, reducing the need for ultra-fast columns in the 2D. Furthermore, it enables the application of various mobile phase compositions in the 2D. Finally, this tool was successfully used to analyze compounds in urine and plasma matrices.
Disciplines :
Chemistry
Author, co-author :
Rahmani, Turaj ; Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, Ghent B-9000, Belgium
Bandini, Elena ; Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, Ghent B-9000, Belgium
Schuster, Stephanie A ; Advanced Materials Technology, Inc., Wilmington, DE 19810, United States
Iterbeke, Lander ; Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, Ghent B-9000, Belgium
Focant, Jean-François ; Université de Liège - ULiège > Département de chimie (sciences) > Chimie analytique, organique et biologique
Lynen, Frédéric ; Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, Ghent B-9000, Belgium. Electronic address: frederic.lynen@ugent.be
Language :
English
Title :
Combining per-aqueous and chiral reversed phase separation modes towards an enhanced comprehensive 2-dimensional liquid chromatographic based chiral screening platform.
The authors gratefully acknowledged the FWO for funding this research through the Excellence of Science grant (EOS 30897864). Special thanks to Agilent Technologies for providing the LC \u00D7 LC instrumentation through a university relations grant, and to Advanced Materials Technology for supplying the HALO\u00AE Penta-HILIC column.The authors gratefully acknowledged the FWO for funding this research through the Excellence of Science grant (EOS 30897864 ). Special thanks to Agilent Technologies for providing the LC\u202F\u00D7\u202FLC instrumentation through a university relations grant, and to Advanced Materials Technology for supplying the HALO\u00AE Penta-HILIC column.
Vashistha, V.K., Detection and remediation of chiral pharmaceuticals from wastewater: a review. Chirality 34 (2022), 833–847.
Ceramella, J., Iacopetta, D., Franchini, A., De Luca, M., Saturnino, C., Andreu, I., Sinicropi, M.S., Catalano, A., A look at the importance of chirality in drug activity: some significative examples. Appl. Sci., 12, 2022, 10909.
Hegade, R.S., De Beer, M., Lynen, F., Chiral stationary phase optimized selectivity liquid chromatography: a strategy for the separation of chiral isomers. J. Chromatogr. A 1515 (2017), 109–117, 10.1016/j.chroma.2017.07.078.
Liu, T., Li, Z., Wang, J., Chen, J., Guan, M., Qiu, H., Solid membranes for chiral separation: a review. Chem. Eng. J., 410, 2021, 128247, 10.1016/j.cej.2020.128247.
Zhang, B., Sun, X., Du, P., Designing single chirality via crystallization method: spontaneous chiral symmetry breaking and deracemization. Mater. Today Chem., 32, 2023, 101636, 10.1016/j.mtchem.2023.101636.
Naghdi, E., Ahmadloo, R., Shadi, M., Moran, G.E., Chiral purification by enantioselective extraction: principles and recent development, Trends Environ. Anal. Chem., 40, 2023, e00219, 10.1016/j.teac.2023.e00219.
Wu, J., Li, L., Cao, L., Liu, X., Li, R., Ji, Y., Chirality-controlled mercapto-β-cyclodextrin covalent organic frameworks for selective adsorption and chromatographic enantioseparation. ACS Appl. Mater. Interfaces 15 (2023), 27214–27222, 10.1021/acsami.3c04066.
Qian, H.L., Xu, S.T., Yan, X.P., Recent advances in separation and analysis of chiral compounds. Anal. Chem. 95 (2023), 304–318, 10.1021/acs.analchem.2c04371.
Liu, H., Wu, Z., Chen, J., Wang, J., Qiu, H., Recent advances in chiral liquid chromatography stationary phases for pharmaceutical analysis. J. Chromatogr. A, 1708, 2023, 464367, 10.1016/j.chroma.2023.464367.
Ismail, O.H., Pasti, L., Ciogli, A., Villani, C., Kocergin, J., Anderson, S., Gasparrini, F., Cavazzini, A., Catani, M., Pirkle-type chiral stationary phase on core–shell and fully porous particles: are superficially porous particles always the better choice toward ultrafast high-performance enantioseparations?. J. Chromatogr. A 1466 (2016), 96–104, 10.1016/j.chroma.2016.09.001.
Rahmani, T., Ampe, A., Lynen, F., Temperature responsive × fast chiral comprehensive liquid chromatography: a new 2D-LC platform for resolving mixtures of chiral isomers. Anal. Chem. 95 (2023), 8763–8769, 10.1021/acs.analchem.3c00780.
van den Hurk, R.S., Pursch, M., Stoll, D.R., Pirok, B.W.J., Recent trends in two-dimensional liquid chromatography. Trends Anal. Chem., 166, 2023, 117166, 10.1016/j.trac.2023.117166.
Woiwode, U., Neubauer, S., Lindner, W., Buckenmaier, S., Lämmerhofer, M., Enantioselective multiple heartcut two-dimensional ultra-high-performance liquid chromatography method with a coreshell chiral stationary phase in the second dimension for analysis of all proteinogenic amino acids in a single run. J. Chromatogr. A 1562 (2018), 69–77, 10.1016/j.chroma.2018.05.062.
Karongo, R., Ge, M., Geibel, C., Horak, J., Lämmerhofer, M., Enantioselective multiple heart cutting online two-dimensional liquid chromatography-mass spectrometry of all proteinogenic amino acids with second dimension chiral separations in one-minute time scales on a chiral tandem column. Anal. Chim. Acta, 1180, 2021, 10.1016/j.aca.2021.338858.
Woiwode, U., Ferri, M., Maier, N.M., Lindner, W., Lämmerhofer, M., Complementary enantioselectivity profiles of chiral cinchonan carbamate selectors with distinct carbamate residues and their implementation in enantioselective two-dimensional high-performance liquid chromatography of amino acids. J. Chromatogr. A 1558 (2018), 29–36, 10.1016/j.chroma.2018.04.061.
Yang, Y., Rosales-Conrado, N., Guillén-Casla, V., León-González, M.E., Pérez-Arribas, L.V., Polo-Díez, L.M., Chiral determination of salbutamol, salmeterol and atenolol by two-dimensional LC-LC: application to urine samples. Chromatographia 75 (2012), 1365–1375, 10.1007/s10337-012-2353-y.
Alvim, J., Lopes, B.R., Cass, Q.B., Simultaneous enantioselective quantification of fluoxetine and norfluoxetine in human milk by direct sample injection using 2-dimensional liquid chromatography-tandem mass spectrometry. J. Chromatogr. A 1451 (2016), 120–126, 10.1016/j.chroma.2016.05.022.
Suryakant, R., Chen, K., Boon, J., Hellings, M., Wicht, K., Lynen, F., Development of an achiral-chiral 2-dimensional heart-cutting platform for enhanced pharmaceutical impurity analysis. J. Chromatogr. A, 1628, 2020, 461425, 10.1016/j.chroma.2020.461425.
I.W. Wainer, The application of achiral/chiral coupled-column high-performance liquid chromatography to biomedical analysis, 1989.
Barhate, C.L., Regalado, E.L., Contrella, N.D., Lee, J., Jo, J., Makarov, A.A., Armstrong, D.W., Welch, C.J., Ultrafast chiral chromatography as the second dimension in two-dimensional liquid chromatography experiments. Anal. Chem. 89 (2017), 3545–3553, 10.1021/acs.analchem.6b04834.
Xu, F., Xu, Y., Liu, G., Zhang, M., Qiang, S., Kang, J., Separation of twelve posaconazole related stereoisomers by multiple heart-cutting chiral–chiral two-dimensional liquid chromatography. J. Chromatogr. A, 2020, 1618, 10.1016/j.chroma.2019.460845.
Sheng, N., Zheng, H., Xiao, Y., Wang, Z., Li, M., Zhang, J., Chiral separation and chemical profile of Dengzhan Shengmai by integrating comprehensive with multiple heart-cutting two-dimensional liquid chromatography coupled with quadrupole time-of-flight mass spectrometry. J. Chromatogr. A 1517 (2017), 97–107, 10.1016/j.chroma.2017.08.037.
Lin, J., Tsang, C., Lieu, R., Zhang, K., Fast chiral and achiral profiling of compounds with multiple chiral centers by a versatile two-dimensional multicolumn liquid chromatography (LC–mLC) approach. J. Chromatogr. A, 2020, 1620, 10.1016/j.chroma.2020.460987.
Potts, L.W., Stoll, D.R., Li, X., Carr, P.W., The impact of sampling time on peak capacity and analysis speed in on-line comprehensive two-dimensional liquid chromatography. J. Chromatogr. A 1217 (2010), 5700–5709.
Díaz Merino, M.E., Acquaviva, A., Padró, J.M., Castells, C.B., Comprehensive two-dimensional liquid chromatographic method (Chiral × Achiral) for the simultaneous resolution of pesticides. J. Chromatogr. A, 2022, 1673, 10.1016/j.chroma.2022.463126.
Acquaviva, A., Siano, G., Quintas, P., Filgueira, M.R., Castells, C.B., Chiral x achiral multidimensional liquid chromatography. Application to the enantioseparation of dintitrophenyl amino acids in honey samples and their fingerprint classification. J. Chromatogr. A, 2020, 1614, 10.1016/j.chroma.2019.460729.
Baert, M., Martens, S., Desmet, G., De Villiers, A., Du Prez, F., Lynen, F., Enhancing the possibilities of comprehensive two-dimensional liquid chromatography through hyphenation of purely aqueous temperature-responsive and reversed-phase liquid chromatography. Anal. Chem. 90 (2018), 4961–4967, 10.1021/acs.analchem.7b04914.
Karongo, R., Horak, J., Lämmerhofer, M., Comprehensive online reversed-phase × chiral two-dimensional liquid chromatography-mass spectrometry with data-independent sequential window acquisition of all theoretical fragment-ion spectra-acquisition for untargeted enantioselective amino acid analysis. Anal. Chem. 94 (2022), 17063–17072, 10.1021/acs.analchem.2c03042.
Karongo, R., Horak, J., Lämmerhofer, M., Comprehensive reversed-phase×chiral two-dimensional liquid chromatography coupled to quadrupole-time-of-flight tandem mass spectrometry with post-first dimension flow splitting for untargeted enantioselective amino acid analysis. J. Sep. Sci., 46, 2023, 10.1002/jssc.202300351.
Alpert, A.J., Hydrophilic-interaction chromatography for the separation of peptides, nucleic acids and other polar compounds. J. Chromatogr. A 499 (1990), 177–196, 10.1016/S0021-9673(00)96972-3.
McCalley, D.V., Understanding and manipulating the separation in hydrophilic interaction liquid chromatography. J. Chromatogr. A 1523 (2017), 49–71, 10.1016/j.chroma.2017.06.026.
Li, Y., Li, J., Chen, T., Liu, X., Zhang, H., Covalently bonded polysaccharide-modified stationary phase for per aqueous liquid chromatography and hydrophilic interaction chromatography. J. Chromatogr. A 1218 (2011), 1503–1508, 10.1016/j.chroma.2011.01.044.
Li, Y., Xu, L., Chen, T., Liu, X., Xu, Z., Zhang, H., Carbon nanoparticles from corn stalk soot and its novel application as stationary phase of hydrophilic interaction chromatography and per aqueous liquid chromatography. Anal. Chim. Acta 726 (2012), 102–108, 10.1016/j.aca.2012.03.032.
Gritti, F., dos Santos Pereira, A., Sandra, P., Guiochon, G., Comparison of the adsorption mechanisms of pyridine in hydrophilic interaction chromatography and in reversed-phase aqueous liquid chromatography. J. Chromatogr. A 1216 (2009), 8496–8504, 10.1016/j.chroma.2009.10.009.
Gritti, F., dos Santos Pereira, A., Sandra, P., Guiochon, G., Efficiency of the same neat silica column in hydrophilic interaction chromatography and per aqueous liquid chromatography. J. Chromatogr. A 1217 (2010), 683–688, 10.1016/j.chroma.2009.12.004.
Cheng, X., Zhang, Z., Dai, X., Li, Y., Retention behavior of nucleosides and nucleobases on a 3 μ m undecylenic acid-functionalized silica column in per aqueous liquid chromatography and hydrophilic interaction liquid chromatography separation modes. J. Chromatogr. A, 1721, 2024, 464833, 10.1016/j.chroma.2024.464833.
dos Santos Pereira, A., David, F., Vanhoenacker, G., Sandra, P., The acetonitrile shortage: is reversed HILIC with water an alternative for the analysis of highly polar ionizable solutes?. J. Sep. Sci. 32 (2009), 2001–2007, 10.1002/jssc.200900272.
Aboul-Enein, H.Y., Rigi, G., Farhadpour, M., Ghasempour, A., Ahmadian, G., Per aqueous liquid chromatography (PALC) as a simple method for native separation of protein A. Chromatographia 80 (2017), 1633–1639, 10.1007/s10337-017-3412-1.
Redón, L., Subirats, X., Rosés, M., Volume and composition of semi-adsorbed stationary phases in hydrophilic interaction liquid chromatography. Comparison of water adsorption in common stationary phases and eluents. J. Chromatogr. A, 2021, 1656, 10.1016/j.chroma.2021.462543.
Kumar, A., Hart, J.P., McCalley, D.V., Determination of catecholamines in urine using hydrophilic interaction chromatography with electrochemical detection. J. Chromatogr. A 1218 (2011), 3854–3861, 10.1016/j.chroma.2011.04.034.
Chen, T., Zhu, L., Lu, H., Song, G., Li, Y., Zhou, H., Li, P., Zhu, W., Xu, H., Shao, L., Preparation and application of covalently bonded polysaccharide-modified stationary phase for per aqueous liquid chromatography. Anal. Chim. Acta 964 (2017), 195–202, 10.1016/j.aca.2017.02.013.
Chapel, S., Rouvière, F., Guillarme, D., Heinisch, S., Reversed HILIC gradient: a powerful strategy for on-line comprehensive 2D-LC. Molecules 28 (2023), 4–8, 10.3390/molecules28093907.
Kawachi, Y., Ikegami, T., Takubo, H., Ikegami, Y., Miyamoto, M., Tanaka, N., Chromatographic characterization of hydrophilic interaction liquid chromatography stationary phases: hydrophilicity, charge effects, structural selectivity, and separation efficiency. J. Chromatogr. A 1218 (2011), 5903–5919, 10.1016/j.chroma.2011.06.048.
Alpert, A.J., Effect of salts on retention in hydrophilic interaction chromatography. J. Chromatogr. A 1538 (2018), 45–53, 10.1016/j.chroma.2018.01.038.
Niezen, L.E., Staal, B.B.P., Lang, C., Pirok, B.W.J., Schoenmakers, P.J., Thermal modulation to enhance two-dimensional liquid chromatography separations of polymers. J. Chromatogr. A, 1653, 2021, 462429, 10.1016/j.chroma.2021.462429.
Deridder, S., Desmet, G., Broeckhoven, K., Numerical investigation of band spreading generated by flow-through needle and fixed loop sample injectors. J. Chromatogr. A 1552 (2018), 29–42, 10.1016/j.chroma.2018.04.001.
Wang, H., Chen, Y., Zhou, J., Ma, C., Chen, Y., Liu, X., Stereoselective determination of ornidazole enantiomers in human plasma and urine samples by chiral LC: application to pharmacokinetic study. Chromatographia 67 (2008), 875–881, 10.1365/s10337-008-0625-3.
Pinto, L.S.R., do Vale, G.T., de L. Moreira, F., Marques, M.P., Coelho, E.B., Cavalli, R.C., Lanchote, V.L., Direct chiral LC-MS/MS analysis of fexofenadine enantiomers in plasma and urine with application in a maternal-fetal pharmacokinetic study. J. Chromatogr. B:Anal. Technol. Biomed. Life Sci., 1145, 2020, 122094, 10.1016/j.jchromb.2020.122094.