Article (Scientific journals)
The importance of frequency–place mismatch in the quality of sound perceived in single-sided deafness among cochlear implant recipients
Gersdorff, Guillaume; Ivanovic, Nicola; Zoka Assadi, Masoud et al.
2025 • In Frontiers in Audiology and Otology, 3
Editorial Reviewed verified by ORBi
 

Files


Full Text
fauot-3-1648716.pdf
Publisher postprint (824.27 kB) Creative Commons License - Attribution
Download

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] IntroductionSingle-sided deafness (SSD) affects the ability to localize sounds and understand speech in noisy environments, significantly impacting the quality of life. Cochlear implants (CIs) have been explored as a solution for SSD, with varying success attributed to different factors, such as onset of deafness (pre- vs. post-lingual), duration of especially pre-lingual deafness, and compliance to rehab protocols, as well as the frequency-to-place mismatch, where the frequency assigned to CI electrodes does not align with the cochlea's natural tonotopy. The objective is to investigate the influence of frequency-to-place mismatch on hearing performance, sound quality, and patient satisfaction in SSD CI recipients by comparing default and anatomical frequency mapping.MethodsA retrospective study was conducted on 19 SSD patients implanted with MEDEL CIs between 2014 and 2023. Post-activation, high-resolution cone beam computed tomography scans were analyzed using OTOPLAN® (Version V4) to define anatomical frequency mapping. The average frequency mismatch (AFM) between default and anatomical mapping was calculated. Speech intelligibility was assessed using articulation function (AF) scores, and sound quality was evaluated through patient questionnaires.ResultsA significant negative correlation between AFM and AF (R = −0.47, p = 0.042) was observed. Sound quality aspects, including natural sound perception and similarity to the normal ear, inversely correlated with AFM (R2 = 0.281, p = 0.05, and R2 = 0.301, p = 0.043, respectively). Global satisfaction scores were high (3.58 ± 0.77), unaffected by AFM.ConclusionFrequency-to-place mismatch impacts speech intelligibility and sound quality in SSD CI patients. Anatomical frequency mapping using tools like OTOPLAN can enhance CI outcomes, highlighting the need for individualized cochlear measurements and electrode assignment.
Disciplines :
Otolaryngology
Author, co-author :
Gersdorff, Guillaume  ;  Centre Hospitalier Universitaire de Liège - CHU > > Service d'ORL, d'audiophonologie et de chir. cervico-faciale
Ivanovic, Nicola
Zoka Assadi, Masoud
Nopp, Peter
CAMBY, Séverine ;  Centre Hospitalier Universitaire de Liège - CHU > > Service d'ORL, d'audiophonologie et de chir. cervico-faciale
Lefèbvre, Philippe ;  Université de Liège - ULiège > Département des sciences cliniques > Oto-rhino-laryngologie et audiophonologie
Language :
English
Title :
The importance of frequency–place mismatch in the quality of sound perceived in single-sided deafness among cochlear implant recipients
Publication date :
18 August 2025
Journal title :
Frontiers in Audiology and Otology
eISSN :
2813-6055
Publisher :
Frontiers Media SA
Volume :
3
Peer reviewed :
Editorial Reviewed verified by ORBi
Available on ORBi :
since 28 May 2026

Statistics


Number of views
82 (5 by ULiège)
Number of downloads
43 (3 by ULiège)

OpenAlex citations
 
2

Bibliography


Similar publications



Contact ORBi