S.P. Klein, B. Depreitere, G. Meyfroidt, How i monitor cerebral autoregulation . BioMed Central Ltd., Belgium Crit. Care. 1466609X. 23 (1) (2019), doi: 10.1186/s13054-019-2454-1.
R. Aaslid, T.M. Markwalder, H. Nornes, Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries . J. Neurosurg.. 00223085. 57 (6) (1982), 769-774, doi: 10.3171/jns.1982.57.6.0769.
M. Maurer, S. Shambal, D. Berg, M. Woydt, E. Hofmann, D. Georgiadis, A. Lindner, G. Becker, Differentiation between intracerebral hemorrhage and ischemic stroke by transcranial color-coded duplex-sonography . Lippincott Williams and Wilkins, Germany Stroke. 00392499. 29 (12) (1998), 2563-2567, Available from: . doi: 10.1161/01.STR.29.12.2563.
G. Seidel, M. Kaps, T. Gerriets, A. Hutzelmann, Evaluation of the ventricular system in adults by transcranial duplex sonography . J. Neuroimaging. 10512284. 5 (2) (1995), 105-108. doi: 10.1111/jon199552105Germany.
C. Robba, F. Simonassi, L. Ball, P. Pelosi, Transcranial color-coded duplex sonography for bedside monitoring of central nervous system infection as a consequence of decompressive craniectomy after traumatic brain injury . Springer Verlag, Italy Intensive Care Med.. 14321238. 45 (8) (2019), 1143-1144,. doi: 10.1007/s00134-018-5405-4.
J. Motuel, I. Biette, M. Srairi, S. Mrozek, M.M. Kurrek, P. Chaynes, C. Cognard, O. Fourcade, T. Geeraerts, Assessment of brain midline shift using sonography in neurosurgical ICU patients . BioMed Central Ltd., France Crit. Care. 1466609X. 18 (1) (2014). doi: 10.1186/s13054-014-0676-9.
C. Robba, A. Goffi, T. Geeraerts, D. Cardim, G. Via, M. Czosnyka, S. Park, A. Sarwal, L. Padayachy, F. Rasulo, G. Citerio, Brain ultrasonography: methodology, basic and advanced principles and clinical applications. A narrative review . Springer Verlag, Italy Intensive Care Med.. 14321238. 45 (7) (2019), 913-927,. doi: 10.1007/s00134-019-05610-4.
M. Gomez-Choco, S.J. Schreiber, M. Weih, F. Doepp, J.M. Valdueza, Delayed transcranial echo-contrast bolus arrival in unilateral internal carotid artery stenosis and occlusion, Ultrasound Med. Biol.. 1879291X. 41 (7) (2015), 1827-1834. doi: 10.1016/j.ultrasmedbio.2015.03.018.
Arbona F.L. Khabiri B. Norton J.A. 2011 Int. Anesthesiol. Clin. , 10.1097/AIA.0b013e318219b6b4, Ultrasound basics for the busy novice practitioner, 49, 4, 34-51
L. Bathala, M. Mehndiratta, V. Sharma, Transcranial Doppler: technique and common findings (Part 1) . Ann. Indian Acad. Neurol.. 19983549. 16 (2) (2013), 174-179, doi: 10.4103/0972-2327.112460.
J. Naqvi, K.H. Yap, G. Ahmad, J. Ghosh, Transcranial Doppler ultrasound: a review of the physical principles and major applications in critical care . Int. J. Vasc. Med.. 20902832. 2013 (2013), doi: 10.1155/2013/629378.
R. Adams, F. Nichols, E. Carl, D.L. Zhang, D. Hess, V. Mckie, K. Mckie, R. Figueroa, M. Litaker, W. Thompson, The use of transcranial ultrasonography to predict stroke in sickle cell disease . N. Engl. J. Med.. 15334406. 326 (9) (1992), 605-610, doi: 10.1056/NEJM199202273260905.
R.J. Adams, V.C. Mckie, L. Hsu, B. Files, E. Vichinsky, C. Pegelow, M. Abboud, D. Gallagher, A. Kutlar, F.T. Nichols, D.R. Bonds, D. Brambilla, G. Woods, N. Olivieri, C. Driscoll, S. Miller, W. Wang, A. Hurlett, C. Scher, B. Berman, E. Carl, A.M. Jones, E.S. Roach, E. Wright, R.A. Zimmerman, M. Waclawiw, Prevention of a first stroke by transfusions in children with sickle cell anemia and abnormal results on transcranial Doppler ultrasonography . N. Engl. J. Med.. 00284793. 339 (1) (1998), 5-11, doi: 10.1056/NEJM199807023390102.
P. Palazzo, P. Ingrand, P. Agius, R. Belhadj Chaidi, J.P. Neau, Transcranial Doppler to detect right-to-left shunt in cryptogenic acute ischemic stroke . John Wiley and Sons Ltd, France Brain Behav.. 21623279. 9 (1) (2019). doi: 10.1002/brb3.1091.
A.K. Sharma, L. Bathala, A. Batra, M.M. Mehndiratta, V.K. Sharma, Transcranial Doppler: techniques and advanced applications: Part 2 . Medknow Publications, India Ann. Indian Acad. Neurol.. 19983549. 19 (1) (2016), 102-107,. doi: 10.4103/0972-2327.173407.
F.A. Rasulo, R. Bertuetti, Transcranial Doppler and optic nerve sonography . W.B. Saunders, Italy J. Cardiothorac. Vasc. Anesth.. 15328422. 33 (2019), S38,. doi: 10.1053/j.jvca.2019.03.040.
G. Kumar, R.B. Shahripour, M.R. Harrigan, Vasospasm on transcranial Doppler is predictive of delayed cerebral ischemia in aneurysmal subarachnoid hemorrhage: a systematic review and meta-analysis . J. Neurosurg.. 19330693. 124 (5) (2016), 1257-1264. doi: 10.3171/2015.4.JNS15428.
Y.Y. Vora, M. Suarez-Almazor, D.E. Steinke, M.L. Martin, J.M. Findlay, Role of transcranial Doppler monitoring in the diagnosis of cerebral vasospasm after subarachnoid hemorrhage . Neurosurgery. 0148396X. 44 (6) (1999), 1237-1248, doi: 10.1097/00006123-199906000-00039.
M.A. Sloan, A.V. Alexandrov, C.H. Tegeler, M.P. Spencer, L.R. Caplan, E. Feldmann, L.R. Wechsler, D.W. Newell, C.R. Gomez, V.L. Babikian, D. Lefkowitz, R.S. Goldman, C. Armon, C.Y. Hsu, D.S. Goodin, Assessment: transcranial Doppler ultrasonography. Report of the therapeutics and technology assessment subcommittee of the American Academy of Neurology . Lippincott Williams and Wilkins, United States Neurology. 00283878. 62 (9) (2004), 1468-1481,. doi: 10.1212/WNL.62.9.1468.
H.S. Markus, M.J.G. Harrison, Estimation of cerebrovascular reactivity using transcranial Doppler, including the use of breath-holding as the vasodilatory stimulus . Stroke. 15244628. 23 (5) (1992), 668-673, doi: 10.1161/01.STR.23.5.668.
J.R. Vitt, N.E. Loper, S. Mainali, Multimodal and autoregulation monitoring in the neurointensive care unit . Frontiers Media SA, United States Front. Neurol.. 16642295. 14 (2023). doi: 10.3389/fneur.2023.1155986.
S. Kampf, P. Schramm, K.U. Klein, Transcranial Doppler and near infrared spectroscopy in the perioperative period . Lippincott Williams and Wilkins, Austria Curr. Opin. Anaesthesiol.. 14736500. 26 (5) (2013), 543-548,. doi: 10.1097/01.aco.0000432517.70844.a6.
M. Heringlake, C. Garbers, J.H. Kabler, I. Anderson, H. Heinze, J. Schon, K.U. Berger, L. Dibbelt, H.H. Sievers, T. Hanke, Preoperative cerebral oxygen saturation and clinical outcomes in cardiac surgery . Anesthesiology. 15281175. 114 (1) (2011), 58-69, doi: 10.1097/ALN.0b013e3181fef34e.
M.B. Kim, D.S. Ward, C.R. Cartwright, J. Kolano, S. Chlebowski, L.C. Henson, Estimation of jugular venous O2 saturation from cerebral oximetry or arterial O2 saturation during isocapnic hypoxia . J. Clin. Monit. Comput.. 13871307. 16 (3) (2000), 191-199, doi: 10.1023/A:1009940031063.
K.M. Brady, J.K. Lee, K.K. Kibler, P. Smielewski, M. Czosnyka, R.B. Easley, R.C. Koehler, D.H. Shaffner, Continuous time-domain analysis of cerebrovascular autoregulation using near-infrared spectroscopy . Stroke. 00392499. 38 (10) (2007), 2818-2825, doi: 10.1161/STROKEAHA.107.485706.
J. Donnelly, M. Czosnyka, H. Adams, C. Robba, L.A. Steiner, D. Cardim, B. Cabella, X. Liu, A. Ercole, P.J. Hutchinson, D.K. Menon, M.J.H. Aries, P. Smielewski, Individualizing thresholds of cerebral perfusion pressure using estimated limits of autoregulation . Crit. Care Med.. 15300293. 45 (9) (2017), 1464-1471,. doi: 10.1097/CCM.0000000000002575.
K. Brady, B. Joshi, C. Zweifel, P. Smielewski, M. Czosnyka, R.B. Easley, C.W. Hogue, Real-time continuous monitoring of cerebral blood flow autoregulation using near-infrared spectroscopy in patients undergoing cardiopulmonary bypass . Stroke. 00392499. 41 (9) (2010), 1951-1956, doi: 10.1161/STROKEAHA.109.575159.
A.T. Moerman, V.M. Vanbiervliet, A. Van Wesemael, S.M. Bouchez, P.F. Wouters, S.G. De Hert, Assessment of cerebral autoregulation patterns with near-infrared spectroscopy during pharmacological-induced pressure changes . Lippincott Williams and Wilkins, Belgium Anesthesiology. 15281175. 123 (2) (2015), 327-335,. doi: 10.1097/ALN.0000000000000715.
J. Kim, E.J. Ha, H.S. Kim, E.Y. Park, H.C. Lee, Y.H. Choo, Y. Shim, K. Kim, K. Kim, S.B. Lee, Real-time evaluation of cerebral autoregulation based on near-infrared spectroscopy to predict clinical outcome after bypass surgery in moyamoya disease . Hindawi Limited, South Korea BioMed Res. Int.. 23146141. 2022 (2022). doi: 10.1155/2022/3091660.
Y. Zhang, J. Tan, P. Li, X. Zhang, Y. Yang, Y. Liu, Q. Fu, J. Cao, W. Mi, H. Zhang, H. Li, The perioperative application of continuous cerebral autoregulation monitoring for cerebral protection in elderly patients . Ann. Palliat. Med.. 22245839. 10 (4) (2021), 4582-4592, doi: 10.21037/apm-21-707.
M. Nakano, Y. Nomura, G. Whitman, M. Sussman, S. Schena, A. Kilic, C.W. Choi, K. Akiyoshi, K.J. Neufeld, J. Lawton, E. Colantuoni, A. Yamaguchi, M. Wen, P. Smielewski, K. Brady, B. Bush, C.W. Hogue, C.H. Brown, Cerebral autoregulation in the operating room and intensive care unit after cardiac surgery . Brit. J. Anaesth.. 14716771. 126 (5) (2021), 967-974,. doi: 10.1016/j.bja.2020.12.043.
X. Liu, J. Donnelly, K.M. Brady, K. Akiyoshi, B. Bush, R.C. Koehler, J.K. Lee, C.W. Hogue, M. Czosnyka, P. Smielewski, C.H. Brown, Comparison of different metrics of cerebral autoregulation in association with major morbidity and mortality after cardiac surgery . Brit. J. Anaesth.. 14716771. 129 (1) (2022), 22-32,. doi: 10.1016/j.bja.2022.03.029.
T.S. Ko, E. Catennacio, S.S. Shin, J. Stern, S.L. Massey, T.J. Kilbaugh, M. Hwang, Advanced neuromonitoring modalities on the horizon: detection and management of acute brain injury in children . Springer, United States Neurocrit. Care. 15560961. 38 (3) (2023), 791-811,. doi: 10.1007/s12028-023-01690-9.
M. Cannesson, Y. Le Manach, C.K. Hofer, J.P. Goarin, J.J. Lehot, B. Vallet, B. Tavernier, Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness . Anesthesiology. 0003-3022. 115 (2) (2011), 231-241, doi: 10.1097/aln.0b013e318225b80a.
P Grassi, Nigro, K Battaglia, M Barone, F Testa, G. Berlot, Pulse pressure variation as a predictor of fluid responsiveness in mechanically ventilated patients with spontaneous breathing activity: a pragmatic observational study . HSR Proc. Intensiv. Care Cardiovasc. Anesth. 5 (2013), 98-109
P.E. Marik, M. Baram, B. Vahid, Does central venous pressure predict fluid responsiveness?∗: a systematic review of the literature and the tale of seven mares . Chest. 00123692. 134 (1) (2008), 172-178, doi: 10.1378/chest.07-2331.
D. De Backer, J.L. Vincent, Should we measure the central venous pressure to guide fluid management? Ten answers to 10 questions . Crit. Care. 1466609X. 22 (1) (2018),. doi: 10.1186/s13054-018-1959-3.
A. Miller, J. Mandeville, Predicting and measuring fluid responsiveness with echocardiography . Echo Res. Pract.. 20550464. 3 (2) (2016), G1,. doi: 10.1530/ERP-16-0008.
M. Feissel, F. Michard, I. Mangin, O. Ruyer, J.P. Faller, J.L. Teboul, Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock . Chest. 00123692. 119 (3) (2001), 867-873, doi: 10.1378/chest.119.3.867.
C. Barbier, Y. Loubieres, C. Schmit, J. Hayon, J.L. Ricome, F. Jardin, A. Vieillard-Baron, Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients . Intensive Care Med.. 30 (9) (2004), 1740-1746, doi: 10.1007/s00134-004-2259-8.
S.I. Bubenek-Turconi, A. Hendy, S. Baila, A. Dragan, O. Chioncel, L. Valeanu, B. Moroșanu, V.A. Iliescu, The value of a superior vena cava collapsibility index measured with a miniaturized transoesophageal monoplane continuous echocardiography probe to predict fluid responsiveness compared to stroke volume variations in open major vascular surgery: a prospective cohort study . J. Clin. Monit. Comput.. 15732614. 34 (3) (2020), 491-499,. doi: 10.1007/s10877-019-00346-4.
A.P. Hrishi, M. Sethuraman, G. Menon, Quest for the holy grail: assessment of echo-derived dynamic parameters as predictors of fluid responsiveness in patients with acute aneurysmal subarachnoid hemorrhage . Ann. Card Anaesth.. 0971-9784. 21 (3) (2018), 243, doi: 10.4103/aca.aca_141_17.
M. Cannesson, Y. Attof, P. Rosamel, O. Desebbe, P. Joseph, O. Metton, O. Bastien, J.J. Lehot, Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room . Anesthesiology. 15281175. 106 (6) (2007), 1105-1111, doi: 10.1097/01.anes.0000267593.72744.20.
G. Natalini, A. Rosano, M. Taranto, B. Faggian, E. Vittorielli, A. Bernardini, Arterial versus plethysmographic dynamic indices to test responsiveness for testing fluid administration in hypotensive patients: a clinical trial . Anesth. Analg.. 00032999. 103 (6) (2006), 1478-1484, doi: 10.1213/01.ane.0000246811.88524.75.
M. Cannesson, O. Desebbe, P. Rosamel, B. Delannoy, J. Robin, O. Bastien, J.J. Lehot, Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre . Oxford University Press, France Br. J. Anaesth.. 14716771. 101 (2) (2008), 200-206,. doi: 10.1093/bja/aen133.
M. Zimmermann, T. Feibicke, C. Keyl, C. Prasser, S. Moritz, B.M. Graf, C. Wiesenack, Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery . Eur. J. Anaesthesiol.. 13652346. 27 (6) (2010), 555-561, doi: 10.1097/EJA.0b013e328335fbd1.
D.H. Kim, S. Shin, J.Y. Kim, S.H. Kim, M. Jo, Y.S. Choi, Pulse pressure variation and pleth variability index as predictors of fluid responsiveness in patients undergoing spinal surgery in the prone position . Dove Medical Press Ltd., South Korea Therapeut. Clin. Risk Manag.. 1178203X. 14 (2018), 1175-1183,. doi: 10.2147/TCRM.S170395.
C.F.K. Kan, J.D. Skaggs, Current commonly used dynamic parameters and monitoring systems for perioperative goal-directed fluid therapy: a review . Yale Journal of Biology and Medicine Inc., United States Yale J. Biol. Med.. 15514056. 96 (1) (2023), 107-123,. doi: 10.59249/JOAP6662.
P. Forget, F. Lois, M. De Kock, Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management . Lippincott Williams and Wilkins, Belgium Anesth. Analg.. 00032999. 111 (4) (2010), 910-914,. doi: 10.1213/ANE.0b013e3181eb624f.
S.D. Bloria, N.B. Panda, K. Jangra, H. Bhagat, B. Mandal, K. Kataria, R. Chauhan, A. Luthra, S.L. Soni, N. Kaloria, S. Mahajan, S.K. Paul, S. Gupta, S. Agrawal, N. Singla, Goal-directed fluid therapy versus conventional fluid therapy during craniotomy and clipping of cerebral aneurysm: a prospective randomized controlled trial . Lippincott Williams and Wilkins, India J. Neurosurg. Anesthesiol.. 15371921. 34 (4) (2022), 407-414,. doi: 10.1097/ANA.0000000000000769.
A. Dey, P.U. Bidkar, S. Swaminathan, M.K. M, J.J. Joy, M. Balasubramanian, S. Bhimsaria, Comparison of two techniques of goal directed fluid therapy in elective neurosurgical patients-a randomized controlled study . Taylor and Francis Ltd., India Br. J. Neurosurg.. 1360046X. (2023),. doi: 10.1080/02688697.2023.2173722.
M.-O. Fischer, Sandrine L., Benoit T., Chems-Eddine B., Vincent C., Marion H., W. Greub, G. Daccache, C. Hulet, Vincent C., D. Taing, E. Lorne, J.J. Parienti, J.L. Hanouz, Individualized fluid management using the pleth variability index . Anesthesiology. 0003-3022. 133 (1) (2020), 31-40, doi: 10.1097/aln.0000000000003260.
M Guen, Le Gall-Salaun, A Josserand, et al., Goal-Directed Fluid Therapy and major postoperative complications in elective craniotomy. A retrospective analysis of a before-after multicentric study . BMC Anesthesiol.. 23 (2023),
N. Mishra, G. Rath, P. Bithal, A. Chaturvedi, P. Chandra, S. Borkar, Effect of goal-directed intraoperative fluid therapy on duration of hospital stay and postoperative complications in patients undergoing excision of large supratentorial tumors . Wolters Kluwer Medknow Publications, India Neurol. India. 19984022. 70 (1) (2022), 108-114,. doi: 10.4103/0028-3886.336329.
S.C. Sundaram, S.R. Salins, A. Nandha Kumar, G. Korula, Intra-operative fluid management in adult neurosurgical patients undergoing intracranial tumour surgery: randomised control trial comparing Pulse Pressure Variance (PPV) and Central Venous Pressure (CVP) . Journal of Clinical and Diagnostic Research, India J. Clin. Diagn. Res.. 0973709X. 10 (5) (2016). doi: 10.7860/JCDR/2016/18377.7850.
C.Y. Wu, Y.S. Lin, H.M. Tseng, H.L. Cheng, T.S. Lee, P.L. Lin, W.H. Chou, Y.J. Cheng, Comparison of two stroke volume variation-based goal-directed fluid therapies for supratentorial brain tumour resection: a randomized controlled trial . Oxford University Press, Taiwan Br. J. Anaesth.. 14716771. 119 (5) (2017), 934-942,. doi: 10.1093/bja/aex189.
J. Xia, Z. He, X. Cao, X. Che, L. Chen, J. Zhang, W. Liang, The brain relaxation and cerebral metabolism in stroke volume variation-directed fluid therapy during supratentorial tumors resection . J. Neurosurg. Anesthesiol.. 0898-4921. 26 (4) (2014), 320-327, doi: 10.1097/ana.0000000000000046.
O. Broch, B. Bein, M. Gruenewald, J. Hocker, J. Schottler, P. Meybohm, M. Steinfath, J. Renner, Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index . Acta Anaesthesiol. Scand.. 13996576. 55 (6) (2011), 686-693, doi: 10.1111/j.1399-6576.2011.02435.x.
M. Biais, V. Cottenceau, L. Petit, F. Masson, J.F. Cochard, F. Sztark, Impact of norepinephrine on the relationship between pleth variability index and pulse pressure variations in ICU adult patients . Crit. Care. 1466609X. 15 (4) (2011). doi: 10.1186/cc10310France.
H.J. Byon, C.W. Lim, J.H. Lee, Y.H. Park, H.S. Kim, C.S. Kim, J.T. Kim, Prediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery . Oxford University Press, South Korea British J. Anaesth.. 14716771. 110 (4) (2013), 586-591.. doi: 10.1093/bja/aes467.
E. Pereira de Souza Neto, S. Grousson, F. Duflo, C. Ducreux, H. Joly, J. Convert, C. Mottolese, F. Dailler, M. Cannesson, Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography . Br. J. Anaesth.. 00070912. 106 (6) (2011), 856-864, doi: 10.1093/bja/aer090.
H. Gan, M. Cannesson, J.R. Chandler, J.Mark Ansermino, Predicting fluid responsiveness in children . Anesth. Analg.. 0003-2999. 117 (6) (2013), 1380-1392, doi: 10.1213/ane.0b013e3182a9557e.
S.B. Walker, J.M. Winters, J.M. Schauer, P. Murphy, A. Fawcett, L.Nelson Sanchez-Pinto, Performance of tools and measures to predict fluid responsiveness in pediatric shock and critical illness: a systematic review and meta-analysis∗ . Pediatr. Crit. Care Med.. 1529-7535. 25 (1) (2024), 24-36, doi: 10.1097/pcc.0000000000003320.
E. Chung, G. Chen, B. Alexander, M. Cannesson, Non-invasive continuous blood pressure monitoring: a review of current applications . Front. Med. China. 16737458. 7 (1) (2013), 91-101,. doi: 10.1007/s11684-013-0239-5.
Truijen J. Van Lieshout J.J. Wesselink W.A. Westerhof B.E. 2012 J. Clin. Monit. Comput. 10.1007/s10877-012-9375-8 4 267-278 Noninvasive continuous hemodynamic monitoring 26
R.D. Boehmer, Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger . J. Clin. Monit.. 15732614. 3 (4) (1987), 282-287, doi: 10.1007/BF03337384.
P. Gizdulich, A. Prentza, K.H. Wesseling, Models of brachial to finger pulse wave distortion and pressure decrement . Cardiovasc. Res.. 00086363. 33 (3) (1997), 698-705, doi: 10.1016/S0008-6363(97)00003-5.
S.-H. Kim, M. Lilot, K.S. Sidhu, J. Rinehart, Z. Yu, C. Canales, M. Cannesson, Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure . Anesthesiology. 0003-3022. 120 (5) (2014), 1080-1097, doi: 10.1097/aln.0000000000000226.
J.J. Vos, M. Poterman, E.A.Q. Mooyaart, M. Weening, M.M.R.F. Struys, T.W.L. Scheeren, A.F. Kalmar, Comparison of continuous non-invasive finger arterial pressure monitoring with conventional intermittent automated arm arterial pressure measurement in patients under general anaesthesia . Brit. J. Anaesth.. 14716771. 113 (1) (2014), 67-74,. doi: 10.1093/bja/aeu091.
L.S. Nguyen, P. Squara, Non-invasive monitoring of cardiac output in critical care medicine . Front. Med.. 2296858X. 4 (2017). doi: 10.3389/fmed.2017.00200.
T. Panula, J.P. Sirkia, D. Wong, M. Kaisti, Advances in non-invasive blood pressure measurement techniques . IIEEE Rev. Biomed. Eng.. 19411189. 16 (2023), 424-438,. doi: 10.1109/RBME.2022.3141877.
M. Boisson, M.E. Poignard, B. Pontier, O. Mimoz, B. Debaene, D. Frasca, Cardiac output monitoring with thermodilution pulse-contour analysis vs. non-invasive pulse-contour analysis . Anaesthesia. 13652044. 74 (6) (2019), 735-740. doi: 10.1111/anae.14638.
B. Saugel, R.H. Thiele, A. Hapfelmeier, M. Cannesson, Technological assessment and objective evaluation of minimally invasive and noninvasive cardiac output monitoring systems . Anesthesiology. 0003-3022. 133 (4) (2020), 921-928, doi: 10.1097/aln.0000000000003483.
J.L. Vincent, Annual update in intensive care and emergency medicine 2012 . Springer Berlin Heidelberg, Ann. Update Int. Care Emerg. Med.. 2012 (2012), doi: 10.1007/978-3-642-25716-2.
S.M. Romano, M. Pistolesi, Assessment of cardiac output from systemic arterial pressure in humans . Crit. Care Med.. 00903493. 30 (8) (2002), 1834-1841,. doi: 10.1097/00003246-200208000-00027.
K.H. Wesseling, J.R.C. Jansen, J.J. Settels, J.J. Schreuder, Computation of aortic flow from pressure in humans using a nonlinear, three-element model . J. Appl. Physiol.. 87507587. 74 (5) (1993), 2566-2573, doi: 10.1152/jappl.1993.74.5.2566.
M.O. Fischer, A. Joosten, O. Desebbe, M. Boutros, S. Debroczi, O. Broch, M.L.N.G. Malbrain, K. Ameloot, C.K. Hofer, S.I. Bubenek-Turconi, X. Monnet, M. Diouf, E. Lorne, Interchangeability of cardiac output measurements between non-invasive photoplethysmography and bolus thermodilution: a systematic review and individual patient data meta-analysis . Anaesth. Crit. Care Pain Med.. 23525568. 39 (1) (2020), 75-85,. doi: 10.1016/j.accpm.2019.05.007.
A. Joosten, O. Desebbe, K. Suehiro, L.S.L. Murphy, M. Essiet, B. Alexander, M.O. Fischer, L. Barvais, L. Van Obbergh, D. Maucort-Boulch, M. Cannesson, Accuracy and precision of non-invasive cardiac output monitoring devices in perioperative medicine: a systematic review and meta-analysis . Brit. J. Anaesth.. 14716771. 118 (3) (2017), 298-310,. doi: 10.1093/bja/aew461.
H. Keren, D. Burkhoff, P. Squara, Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance . Am. J. Physiol. Heart Circ. Physiol.. 15221539. 293 (1) (2007), H583,. doi: 10.1152/ajpheart.00195.2007Israel.
P. Squara, D. Denjean, P. Estagnasie, A. Brusset, J.C. Dib, C. Dubois, Noninvasive cardiac output monitoring (NICOM): a clinical validation . Intensive Care Med.. 03424642. 33 (7) (2007), 1191-1194, doi: 10.1007/s00134-007-0640-0.
B.B. Pinto, G. Atlas, B.F. Geerts, K. Bendjelid, The use of the oesophageal Doppler in perioperative medicine: new opportunities in research and clinical practice . J. Clin. Monit. Comput.. 15732614. 31 (5) (2017), 895-902,. doi: 10.1007/s10877-016-9926-5.
M. El-Safoury, C. Weber, H. Yassine, J. Wollenstein, K. Schmitt, Towards a miniaturized photoacoustic sensor for transcutaneous CO2 monitoring . Sensors. 1424-8220. 24 (2) (2024), 457, doi: 10.3390/s24020457.
E. Dervieux, F. Guerrero, W. Uhring, M.A. Giroux-Metges, M. Theron, Skin temperature influence on transcutaneous carbon dioxide (CO2) conductivity and skin blood flow in healthy human subjects at the arm and wrist . Front. Physiol.. 1664-042X. 14 (2024), doi: 10.3389/fphys.2023.1293752.
K. Hirata, M. Nishihara, Y. Oshima, S. Hirano, H. Kitajima, Application of transcutaneous carbon dioxide tension monitoring with low electrode temperatures in premature infants in the early postnatal period . Am. J. Perinatol.. 0735-1631. 31 (05) (2014), 435-440, doi: 10.1055/s-0033-1352485.
T. Nishiyama, S. Nakamura, K. Yamashita, Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia . Eur. J. Anaesthesiol.. 13652346. 23 (12) (2006), 1049-1054, doi: 10.1017/S0265021506001116.
T. Nishiyama, S. Nakamura, K. Yamashita, Effects of the electrode temperature of a new monitor, TCM4, on the measurement of transcutaneous oxygen and carbon dioxide tension . J. Anesth.. 09138668. 20 (4) (2006), 331-334, doi: 10.1007/s00540-006-0422-9.
W. Wang, Z. Zhao, X. Tian, X. Ma, L. Xu, G. Shang, Noninvasive carbon dioxide monitoring in pediatric patients undergoing laparoscopic surgery: transcutaneous vs. end-tidal techniques . BMC Pediatr.. 14712431. 23 (1) (2023). doi: 10.1186/s12887-023-03836-2.
T.B. Tufan, L. Rhein, U. Guler, Implementation techniques for transcutaneous carbon dioxide monitoring: approaches for wearable smart health applications . IEEE Trans. Biomed. Eng.. 15582531. 71 (3) (2024), 929-943,. doi: 10.1109/TBME.2023.3322871.
JP Cascales, X Li, E Roussakis, CL. Evans, A patient-ready wearable transcutaneous CO2 sensor . Biosensors 12 (2022
V.V. Tipparaju, S.J. Mora, J. Yu, F. Tsow, X. Xian, Wearable transcutaneous CO monitor based on miniaturized nondispersive infrared sensor . Institute of Electrical and Electronics Engineers Inc., United States IEEE Sens. J.. 15581748. 21 (15) (2021), 17327-17334,. doi: 10.1109/JSEN.2021.3081696.
U. Carmi, M.R. Kramer, D. Zemtzov, D. Rosengarten, O. Fruchter, Propofol safety in bronchoscopy: prospective randomized trial using transcutaneous carbon dioxide tension monitoring . Respiration. 14230356. 82 (6) (2011), 515-521, doi: 10.1159/000331506.
L.T. Heuss, P.N. Chhajed, P. Schnieper, T. Hirt, C. Beglinger, Combined pulse oximetry/cutaneous carbon dioxide tension monitoring during colonoscopies: pilot study with a smart ear clip . Digestion. 00122823. 70 (3) (2004), 152-158, doi: 10.1159/000081515.
N. Yazawa, Y. Nakamura, A. Takemasa, N. Uchida, Y. Kushima, M. Masawa, H. Okutomi, S. Soda, N. Ikeda, R. Arai, K. Chibana, S. Niho, Y. Shimizu, Transcutaneous gas monitoring is a useful tool to detect respiratory depression during bronchoscopy performed under propofol sedation . Respir. Investig.. 22125353. 61 (6) (2023), 793-799,. doi: 10.1016/j.resinv.2023.08.009.
H.J. Lee, J.H. Woo, S. Cho, S. Moon, S.W. Sung, Transcutaneous carbon dioxide monitoring more accurately detects hypercapnia than end-tidal carbon dioxide monitoring during non-intubated video-assisted thoracic surgery: a retrospective cohort study . J. Clin. Med.. 20770383. 12 (4) (2023). doi: 10.3390/jcm12041706.
A.M. Kelly, S. Klim, Agreement between arterial and transcutaneous PCO2 in patients undergoing non-invasive ventilation . Respir. Med.. 09546111. 105 (2) (2011), 226-229, doi: 10.1016/j.rmed.2010.11.010.
S.A. Thy, A.O. Johansen, A. Thy, H.H. Soerensen, J. Moelgaard, N.B. Foss, P. Toft, C.S. Meyhoff, E.K. Aasvang, Associations between clinical interventions and transcutaneous blood gas values in postoperative patients . J. Clin. Monit. Comput.. 15732614. 37 (5) (2023), 1255-1264,. doi: 10.1007/s10877-023-00982-x.
G.W.J. Hawryluk, G. Citerio, P. Hutchinson, A. Kolias, G. Meyfroidt, C. Robba, N. Stocchetti, R. Chesnut, Intracranial pressure: current perspectives on physiology and monitoring . Springer Science and Business Media Deutschland GmbH, Canada Intensive Care Med.. 14321238. 48 (10) (2022), 1471-1481,. doi: 10.1007/s00134-022-06786-y.
P. Le Roux, D.K. Menon, G. Citerio, P. Vespa, M.K. Bader, G. Brophy, M.N. Diringer, N. Stocchetti, W. Videtta, R. Armonda, N. Badjatia, J. Bosel, R. Chesnut, S. Chou, J. Claassen, M. Czosnyka, M. De Georgia, A. Figaji, J. Fugate, R. Helbok, D. Horowitz, P. Hutchinson, M. Kumar, M. McNett, C. Miller, A. Naidech, M. Oddo, D.W. Olson, K. O'Phelan, J. Javier Provencio, C. Puppo, R. Riker, C. Roberson, M. Schmidt, F. Taccone, The international multidisciplinary consensus conference on multimodality monitoring in neurocritical care: evidentiary tables: a statement for healthcare professionals from the neurocritical care society and the European society of intensive care medicine . Neurocrit. Care. 15560961. 21 (2) (2014), 297-361,. doi: 10.1007/s12028-014-0081-x.
N. Carney, A.M. Totten, C. O'Reilly, J.S. Ullman, G.W.J. Hawryluk, M.J. Bell, S.L. Bratton, R. Chesnut, O.A. Harris, N. Kissoon, A.M. Rubiano, L. Shutter, R.C. Tasker, M.S. Vavilala, J. Wilberger, D.W. Wright, J. Ghajar, Guidelines for the management of severe traumatic brain injury, fourth edition . Neurosurgery. 15244040. 80 (1) (2017), 6-15, doi: 10.1227/NEU.0000000000001432.
A.S. Alali, N. Temkin, J. Barber, J. Pridgeon, K. Chaddock, S. Dikmen, P. Hendrickson, W. Videtta, S. Lujan, G. Petroni, N. Guadagnoli, Z. Urbina, R.M. Chesnut, A clinical decision rule to predict intracranial hypertension in severe traumatic brain injury . J. Neurosurg.. 19330693. 131 (2) (2019), 612-619,. doi: 10.3171/2018.4.JNS173166.
J. Dimitriou, M. Levivier, M. Gugliotta, Comparison of complications in patients receiving different types of intracranial pressure monitoring: a retrospective study in a single center in Switzerland . Elsevier Inc., Switzerland World Neurosurg.. 18788769. 89 (2016), 641-646,. doi: 10.1016/j.wneu.2015.11.037.
G. Cucciolini, V. Motroni, M. Czosnyka, Intracranial pressure for clinicians: it is not just a number . J. Anesth. Analg. Crit. Care. 27313786. 3 (1) (2023). doi: 10.1186/s44158-023-00115-5.
M. Czosnyka, D.J. Price, M. Williamson, Monitoring of cerebrospinal dynamics using continuous analysis of intracranial pressure and cerebral perfusion pressure in head injury . Acta Neurochir.. 09420940. 126 (2-4) (1994), 113-119, doi: 10.1007/BF01476419.
N.J. Alperin, S.H. Lee, F. Loth, P.B. Raksin, T. Lichtor, MR-intracranial pressure (ICP): a method to measure intracranial elastance and pressure noninvasively by means of MR imaging: baboon and human study . Radiology. 00338419. 217 (3) (2000), 877-885,. doi: 10.1148/radiology.217.3.r00dc42877.
H. Kristiansson, E. Nissborg, J. Bartek, M. Andresen, P. Reinstrup, B. Romner, Measuring elevated intracranial pressure through noninvasive methods: a review of the literature . J. Neurosurg. Anesthesiol.. 15371921. 25 (4) (2013), 372-385, doi: 10.1097/ANA.0b013e31829795ce.
D. Andrew Price, A. Grzybowski, J. Eikenberry, I. Januleviciene, A.C.V. Vercellin, S. Mathew, B. Siesky, A. Harris, Review of non-invasive intracranial pressure measurement techniques for ophthalmology applications . Br. J. Ophthalmol.. 0007-1161. 104 (7) (2020), 887-892, doi: 10.1136/bjophthalmol-2019-314704.
X. Xie, X. Zhang, J. Fu, H. Wang, J.B Jonas, X. Peng, G. Tian, J. Xian, R. Ritch, L. Li, Z. Kang, S. Zhang, D. Yang, N. Wang, Noninvasive intracranial pressure estimation by orbital subarachnoid space measurement: the Beijing Intracranial and Intraocular Pressure (iCOP) study . Crit. Care. 1364-8535. 17 (4) (2013), R162, doi: 10.1186/cc12841.
D. Cardim, C. Robba, M. Bohdanowicz, J. Donnelly, B. Cabella, X. Liu, M. Cabeleira, P. Smielewski, B. Schmidt, M. Czosnyka, Non-invasive monitoring of intracranial pressure using transcranial Doppler ultrasonography: is it possible? . Humana Press Inc., United Kingdom Neurocrit. Care. 15560961. 25 (3) (2016), 473-491,. doi: 10.1007/s12028-016-0258-6.
D. Cardim, C. Robba, J. Donnelly, M. Bohdanowicz, B. Schmidt, M. Damian, G.V. Varsos, X. Liu, M. Cabeleira, G. Frigieri, B. Cabella, P. Smielewski, S. Mascarenhas, M. Czosnyka, Prospective study on noninvasive assessment of intracranial pressure in traumatic brain-injured patients: comparison of four methods . Mary Ann Liebert Inc., United Kingdom J. Neurotrauma. 15579042. 33 (8) (2016), 792-802,. doi: 10.1089/neu.2015.4134.
S. Krakauskaite, V. Petkus, L. Bartusis, R. Zakelis, R. Chomskis, A. Preiksaitis, A. Ragauskas, V. Matijosaitis, K. Petrikonis, D. Rastenyte, Accuracy, precision, sensitivity, and specificity of noninvasive ICP absolute value measurements. Acta Neurochir. Suppl.. 21978395. 122 (2016), 317-321,. doi: 10.1007/978-3-319-22533-3_63.
C. Robba, D. Cardim, T. Tajsic, J. Pietersen, M. Bulman, J. Donnelly, A. Lavinio, A. Gupta, D.K. Menon, P.J.A. Hutchinson, M. Czosnyka, M. Schreiber, Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study . PLoS Med.. 1549-1676. 14 (7) (2017), e1002356, doi: 10.1371/journal.pmed.1002356.
K Martinez-Palacios, S Vasquez-Garcia, Fariyike, C Robba, AM. Rubiano, Noninvasive methods for intracranial pressure (ICP) monitoring in traumatic brain injury using transcranial Doppler (TCD): a scoping review . J. Neurotrauma. (2023),
O. Pranevicius, K. Bertasius, M. Pranevicius, E. Jarzemskas, Non-invasive dynamic assessment of the elasticity of intracranial structures . Acta Neurol. Scand.. 16000404. 86 (5) (1992), 512-516, doi: 10.1111/j.1600-0404.1992.tb05134.x.
D. Michaeli, Z.H. Rappaport, Tissue resonance analysis; a novel method for noninvasive monitoring of intracranial pressure: technical note . J. Neurosurg.. 00223085. 96 (6) (2002), 1132-1137,. doi: 10.3171/jns.2002.96.6.1132.
M.S. Sekhon, D.E. Griesdale, C. Robba, N. McGlashan, E. Needham, K. Walland, A.C. Shook, P. Smielewski, M. Czosnyka, A.K. Gupta, D.K. Menon, Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury . Intensive Care Med.. 14321238. 40 (9) (2014), 1267-1274,. doi: 10.1007/s00134-014-3392-7.
M. Singh, V. Gupta, R. Gupta, B. Kumar, D. Agrawal, A novel method for prediction of raised intracranial pressure through automated ONSD and ETD ratio measurement from ocular ultrasound . SAGE Publications Inc., India Ultrason. Imag.. 10960910. 46 (1) (2024), 29-40,. doi: 10.1177/01617346231197593.
G. Xu, X. Wu, J. Yu, H. Ding, Z. Ni, Y. Wang, Non-invasive intracranial pressure assessment using shear-wave elastography in neuro-critical care patients . Churchill Livingstone, China J. Clin. Neurosci.. 15322653. 99 (2022), 261-267,. doi: 10.1016/j.jocn.2022.03.011.
M.S. Andersen, C.B. Pedersen, F.R. Poulsen, A new novel method for assessing intracranial pressure using non-invasive fundus images: a pilot study . Sci. Rep.. 20452322. 10 (1) (2020), . doi: 10.1038/s41598-020-70084-0.
W.H. Morgan, A. Vukmirovic, A. Abdul-Rahman, Y.J. Khoo, A.G. Kermode, C.R. Lind, J. Dunuwille, D.Y. Yu, Zero retinal vein pulsation amplitude extrapolated model in non-invasive intracranial pressure estimation . Sci. Rep.. 20452322. 12 (1) (2022). doi: 10.1038/s41598-022-09151-7.
P. Auinger, M. Durbin, S. Feldon, M. Garvin, R. Kardon, J. Keltner, M.J Kupersmith, P. Sibony, Kim P., J.-K. Wang, J.S Werner, Baseline OCT measurements in the idiopathic intracranial hypertension treatment trial, part II: correlations and relationship to clinical features. . Investig. Ophthalmol. Vis. Sci.. 55 (12) (2014), 8173-8179, doi: 10.1167/iovs.14-14961.
H. Chen, J. Wang, S. Mao, W. Dong, H. Yang, A new method of intracranial pressure monitoring by EEG power spectrum analysis . Canadian Journal of Neurological Sciences, China Canad. J. Neurol. Sci.. 03171671. 39 (4) (2012), 483-487,. doi: 10.1017/S0317167100013998.
D.H. York, M.W. Pulliam, J.G. Rosenfeld, C. Watts, Relationship between visual evoked potentials and intracranial pressure . J. Neurosurg.. 00223085. 55 (6) (1981), 909-916, doi: 10.3171/jns.1981.55.6.0909.
K.B. Evensen, K. Paulat, F. Prieur, S. Holm, P.K. Eide, Utility of the tympanic membrane pressure waveform for non-invasive estimation of the intracranial pressure waveform . Sci. Rep.. 20452322. 8 (1) (2018). doi: 10.1038/s41598-018-34083-6.
A. Uryga, A. Kazimierska, M. Popek, B. Dragan, M. Burzynska, M. Masalski, M. Kasprowicz, Applying video motion magnification to reveal spontaneous tympanic membrane displacement as an indirect measure of intracranial pressure in patients with brain pathologies . Acta Neurochir.. 09420940. 165 (8) (2023), 2227-2235,. doi: 10.1007/s00701-023-05681-9.
A. Reid, R.J. Marchbanks, D.E. Bateman, A.M. Martin, A.P. Brightwell, J.D. Pickard, Mean intracranial pressure monitoring by a non-invasive audiological technique: a pilot study . J. Neurol. Neurosurg. Psychiatry. 00223050. 52 (5) (1989), 610-612, doi: 10.1136/jnnp.52.5.610.
B. Buki, P. Avan, J.J. Lemaire, M. Dordain, J. Chazal, O. Ribari, Otoacoustic emissions: a new tool for monitoring intracranial pressure changes through stapes displacements . Hearing Res.. 03785955. 94 (1-2) (1996), 125-139,. doi: 10.1016/0378-5955(96)00015-9.
M Lenhardt, K Ward, R. Kotihal, Noninvasive acoustic intracranial pressure measurement through the eye . Int. Tinnitus J. 16 (2011), 154-160
S. Brasil, G. Frigieri, F.S. Taccone, C. Robba, D.J.F. Solla, R. de Carvalho Nogueira, M.H. Yoshikawa, M.J. Teixeira, L.M.S. Malbouisson, W.S. Paiva, Noninvasive intracranial pressure waveforms for estimation of intracranial hypertension and outcome prediction in acute brain-injured patients . J. Clin. Monit. Comput.. 15732614. 37 (3) (2023), 753-760,. doi: 10.1007/s10877-022-00941-y.
M.M. da Costa, A.L.L. Sousa, M.C. Correia, S. Inuzuka, T.O. Costa, P.V.O. Vitorino, P.V. de Toledo Piza, G. Frigieri, A. Coca, W.K.S. Barroso, Intracranial pressure waveform in patients with essential hypertension . Front. Cardiovasc. Med.. 2297055X. 10 (2023). doi: 10.3389/fcvm.2023.1288080.
F.M. de Moraes, E.N.B. Adissy, E. Rocha, F.C.D. Barros, F.G.R. Freitas, M. Miranda, R.A. Valiente, J.B.C. de Andrade, F.E.A. Chaddad-Neto, G.S. Silva, Multimodal monitoring intracranial pressure by invasive and noninvasive means . Sci. Rep.. 20452322. 13 (1) (2023). doi: 10.1038/s41598-023-45834-5.
H. Liu, F. Pan, X. Lei, J. Hui, R. Gong, J. Feng, D. Zheng, Effect of intracranial pressure on photoplethysmographic waveform in different cerebral perfusion territories: a computational study . Front. Physiol.. 1664042X. 14 (2023). doi: 10.3389/fphys.2023.1085871.
M. Roldan, G.R.E. Bradley, E. Mejia-Mejia, T.Y. Abay, P.A. Kyriacou, Non-invasive monitoring of intracranial pressure changes: healthy volunteers study . Front. Physiol.. 1664042X. 14 (2023). doi: 10.3389/fphys.2023.1208010.
M Roldan, PA. Kyriacou, Near-infrared spectroscopy (NIRS) in traumatic brain injury (TBI) . Sensors. 21 (2021
J.E. Cottrell, J. Hartung, Developmental disability in the young and postoperative cognitive dysfunction in the elderly after anesthesia and surgery: do data justify changing clinical practice? . MSJM (Mt. Sinai J. Med.). 19317581. 79 (1) (2012), 75-94, doi: 10.1002/msj.21283.
M. Gaudino, C. Benesch, F. Bakaeen, A. Deanda, S.E. Fremes, L. Glance, S.R. Messe, A. Pandey, L.Q. Rong, Considerations for reduction of risk of perioperative stroke in adult patients undergoing cardiac and thoracic aortic operations: a scientific statement from the American heart association . Circulation. 15244539. 142 (14) (2020), E193,. doi: 10.1161/CIR.0000000000000885.
H.B. Nielsen, Systematic review of near-infrared spectroscopy determined cerebral oxygenation during non-cardiac surgery . Front. Physiol.. 1664042X. 5 (2014),. doi: 10.3389/fphys.2014.00093.
H. Soerensen, H.P. Grocott, N.H. Secher, Near infrared spectroscopy for frontal lobe oxygenation during non-vascular abdominal surgeryClin. Physiol. Funct. Imag.. 1475097X. 36 (6) (2016), 427-435. doi: 10.1111/cpf.12244.
P.J.W. Bevan, Should cerebral near-infrared spectroscopy be standard of care in adult cardiac surgery? . Heart Lung Circ.. 14442892. 24 (6) (2015), 544-550,. doi: 10.1016/j.hlc.2015.01.011.
F. Zheng, R. Sheinberg, May-Sann Y., M. Ono, Y. Zheng, C.W. Hogue, Cerebral near-infrared spectroscopy monitoring and neurologic outcomes in adult cardiac surgery patients . Anesth. Analg.. 0003-2999. 116 (3) (2013), 663-676, doi: 10.1213/ane.0b013e318277a255.
K. Orihashi, T. Sueda, K. Okada, K. Imai, Near-infrared spectroscopy for monitoring cerebral ischemia during selective cerebral perfusion . Eur. J. Cardio. Thorac. Surg.. 10107940. 26 (5) (2004), 907-911, doi: 10.1016/j.ejcts.2004.06.014.
A. Prabhune, A. Sehic, P.A. Spence, T. Church, H.L. Edmonds, Cerebral oximetry provides early warning of oxygen delivery failure during cardiopulmonary bypass . J. Cardiothorac. Vasc. Anesth.. 10530770. 16 (2) (2002), 204-206,. doi: 10.1053/jcan.2002.31069.
W.J. Vernick, A. Oware, Early diagnosis of superior vena cava obstruction facilitated by the use of cerebral oximetry . J. Cardiothorac. Vasc. Anesth.. 15328422. 25 (6) (2011), 1101-1103, doi: 10.1053/j.jvca.2010.08.018.
S. Kimura, K. Shimizu, K. Izumi, T. Kanazawa, K. Mizuno, T. Iwasaki, H. Morimatsu, Regional cerebral oxygen saturation and estimated oxygen extraction ratio as predictive markers of major adverse events in infants with congenital heart disease . Pediatr. Cardiol.. 14321971. (2023), . doi: 10.1007/s00246-023-03158-1.
A.M. Ali, D. Green, H. Zayed, M. Halawa, K. El-Sakka, H.I. Rashid, Cerebral monitoring in patients undergoing carotid endarterectomy using a triple assessment technique . Interact. Cardiovasc. Thorac. Surg.. 15699285. 12 (3) (2011), 454-457,. doi: 10.1510/icvts.2010.235598UnitedKingdom.
J.C. Ritter, D. Green, H. Slim, A. Tiwari, J. Brown, H. Rashid, The role of cerebral oximetry in combination with awake testing in patients undergoing carotid endarterectomy under local anaesthesia . Eur. J. Vasc. Endovasc. Surg.. 15322165. 41 (5) (2011), 599-605, doi: 10.1016/j.ejvs.2010.12.009.
S. Matsumoto, I. Nakahara, T. Higashi, Y. Iwamuro, Y. Watanabe, K. Takahashi, M. Ando, M. Takezawa, J.I. Kira, Near-infrared spectroscopy in carotid artery stenting predicts cerebral hyperperfusion syndrome . Lippincott Williams and Wilkins, Japan Neurology. 1526632X. 72 (17) (2009), 1512-1518,. doi: 10.1212/WNL.0b013e3181a2e846.
C.W.A. Pennekamp, R.V. Immink, H.M. Den Ruijter, L.J. Kappelle, C.M. Ferrier, M.L. Bots, W.F. Buhre, F.L. Moll, G.J. De Borst, Near-infrared spectroscopy can predict the onset of cerebral hyperperfusion syndrome after carotid endarterectomy . Cerebrovasc. Dis.. 14219786. 34 (4) (2012), 314-321, doi: 10.1159/000343229.
J.T. Thomas, A.P. Ajay, R. Praveen, M. Sethuraman, U. Prathapadas, S. Vimala, O. Mathew, Use of near infrared spectroscopy for the prediction of perioperative complications in patients undergoing elective microsurgical resection of cerebral arteriovenous malformations- a prospective observational trial (NIRSCAM trial) . J. Clin. Monitor. Comput.. 15732614. (2023), . doi: 10.1007/s10877-023-01084-4.
PL Purdon, A Sampson, KJ Pavone, EN. Brown, Clinical electroencephalography for anesthesiologists. Part I: background and basic signatures . Anesthesiology. (2015),
C. Lewis, S.D. Parulkar, J. Bebawy, S. Sherwani, C.W. Hogue, Cerebral neuromonitoring during cardiac surgery: a critical appraisal with an emphasis on near-infrared spectroscopy . J. Cardiothorac. Vasc. Anesth.. 15328422. 32 (5) (2018), 2313-2322,. doi: 10.1053/j.jvca.2018.03.032.
M.J. Estruch-Perez, A. Ausina-Aguilar, M. Barbera-Alacreu, J. Sanchez-Morillo, C. Solaz-Roldan, M.M. Morales-Suarez-Varela, Bispectral index changes in carotid surgery . Ann. Vasc. Surg.. 08905096. 24 (3) (2010), 393-399, doi: 10.1016/j.avsg.2009.08.005.
M.J. Estruch-Perez, M. Barbera-Alacreu, A. Ausina-Aguilar, J. Soliveres-Ripoll, C. Solaz-Roldan, M.M. Morales-Suarez-Varela, Bispectral index variations in patients with neurological deficits during awake carotid endarterectomy . Eur. J. Anaesthesiol.. 13652346. 27 (4) (2010), 359-363,. doi: 10.1097/EJA.0b013e32833618ca.
V. Bonhomme, Q. Desiron, T. Lemineur, J.F. Brichant, P.Y. Dewandre, P. Hans, Bispectral index profile during carotid cross clamping . J. Neurosurg. Anesthesiol.. 08984921. 19 (1) (2007), 49-55, doi: 10.1097/01.ana.0000211031.49420.c8.
A. Deogaonkar, R. Vivar, R.E. Bullock, K. Price, I. Chambers, A.D. Mendelow, Bispectral index monitoring may not reliably indicate cerebral ischaemia during awake carotid endarterectomy . Oxford University Press, United States Br. J. Anaesth.. 00070912. 94 (6) (2005), 800-804,. doi: 10.1093/bja/aei115.
E. Amorim, M. van der Stoel, S.B. Nagaraj, M.M. Ghassemi, J. Jing, U.M. O'Reilly, B.M. Scirica, J.W. Lee, S.S. Cash, M.B. Westover, Quantitative EEG reactivity and machine learning for prognostication in hypoxic-ischemic brain injury . Clin. Neurophysiol.. 18728952. 130 (10) (2019), 1908-1916,. doi: 10.1016/j.clinph.2019.07.014.
B. Foreman, J. Claassen, Quantitative EEG for the detection of brain ischemia. . Crit. Care. 16 (2) (2012), doi: 10.1186/cc11230.
Y. Holler, R. Nardone, Quantitative EEG biomarkers for epilepsy and their relation to chemical biomarkers. . Adv. Clin. Chem.. 102 (2021), 271-336, doi: 10.1016/bs.acc.2020.08.004.
G. Zhao, G. Feng, L. Zhao, S. Feng, Y. An, C. Kong, T. Wang, Application of quantitative electroencephalography in predicting early cerebral ischemia in patients undergoing carotid endarterectomy . Front. Neurol.. 16642295. 14 (2023), doi: 10.3389/fneur.2023.1159788.
D.M. Laman, G.H. Wieneke, H. Van Duijn, R.J. Veldhuizen, A.C. Van Huffelen, QEEG changes during carotid clamping in carotid endarterectomy: spectral edge frequency parameters and relative band power parameters . J. Clin. Neurophysiol.. 22 (4) (2005), 244-252, doi: 10.1097/01.WNP.0000167931.83516.CF.
G.H. Visser, G.H. Wieneke, A.C. Van Huffelen, Carotid endarterectomy monitoring: patterns of spectral EEG changes due to carotid artery clamping . Clin. Neurophysiol.. 13882457. 110 (2) (1999), 286-294, doi: 10.1016/S1388-2457(98)00006-6.
M.N. van Stigt, E.A. Groenendijk, A.A.G.A. van de Munckhof, H.A. Marquering, M.S. Koopman, C.B.L.M. Majoie, Y.B.W.E.M. Roos, J.H.T.M. Koelman, W.V. Potters, J.M. Coutinho, Correlation between EEG spectral power and cerebral perfusion in patients with acute ischemic stroke . Churchill Livingstone, Netherlands J. Clin. Neurosci.. 15322653. 116 (2023), 81-86,. doi: 10.1016/j.jocn.2023.08.021.
M.N van Stigt, A.A G A van de Munckhof, L.C C van Meenen, E.A Groenendijk, M. Theunissen, G. Franschman, M.D Smeekes, J.A F van Grondelle, G. Geuzebroek, A. Siegers, H.A Marquering, C.B L M Majoie, Y.B W E M Roos, J.H T M Koelman, W.V Potters, J.M Coutinho, ELECTRA-STROKE: electroencephalography controlled triage in the ambulance for acute ischemic stroke-Study protocol for a diagnostic trial. . Front. Neurol.. 13 (2022), doi: 10.3389/fneur.2022.1018493.
D. Baron Shahaf, E. Abergel, R.S. Hoffmann, E. Meirovitch, S. Konstadt, D.E Feierman, R. Derman, G. Shahaf, Evaluating a novel EEG-based index for stroke detection under anesthesia during mechanical thrombectomy. . J. Neurosurg. Anesthesiol.. 36 (1) (2024), 60-68, doi: 10.1097/ANA.0000000000000889.
D. Baron Shahaf, D. Hight, H. Kaiser, G. Shahaf, Association between risk of stroke and delirium after cardiac surgery and a new electroencephalogram index of interhemispheric similarity . W.B. Saunders, Israel J. Cardiothorac. Vasc. Anesth.. 15328422. 37 (9) (2023), 1691-1699,. doi: 10.1053/j.jvca.2023.05.033.
S. Moritz, P. Kasprzak, M. Arlt, K. Taeger, C. Metz, Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy . Anesthesiology. 0003-3022. 107 (4) (2007), 563-569, doi: 10.1097/01.anes.0000281894.69422.ff.
V. Bonhomme, C. Staquet, J. Montupil, A. Defresne, M. Kirsch, C. Martial, A. Vanhaudenhuyse, C. Chatelle, S.K. Larroque, F. Raimondo, A. Demertzi, O. Bodart, S. Laureys, O. Gosseries, General anesthesia: a probe to explore consciousness . Front. Syst. Neurosci.. 16625137. 13 (2019), . doi: 10.3389/fnsys.2019.00036.
R.D. Sanders, G. Tononi, S. Laureys, J.W. Sleigh, Unresponsiveness ≠ unconsciousness . Anesthesiology. 15281175. 116 (4) (2012), 946-959, doi: 10.1097/ALN.0b013e318249d0a7.
R.D. Sanders, A. Gaskell, A. Raz, J. Winders, A. Stevanovic, R. Rossaint, C. Boncyk, A. Defresne, G. Tran, S. Tasbihgou, S. Meier, P.E. Vlisides, Hussein F., Aaron H., R.M. Bauer, A. Absalom, G.A. Mashour, Vincent B., M. Coburn, J. Sleigh, Incidence of connected consciousness after tracheal intubation . Anesthesiology. 0003-3022. 126 (2) (2017), 214-222, doi: 10.1097/aln.0000000000001479.
R. Lennertz, K.O. Pryor, A. Raz, M. Parker, V. Bonhomme, P. Schuller, G. Schneider, M. Moore, M. Coburn, J.C. Root, J.M. Emerson, A.L. Hohmann, H. Azaria, N. Golomb, A. Defresne, J. Montupil, S. Pilge, D.P. Obert, H. van Waart, M. Seretny, R. Rossaint, A. Kowark, A. Blair, B. Krause, A. Proekt, M. Kelz, J. Sleigh, A. Gaskell, R.D. Sanders, Connected consciousness after tracheal intubation in young adults: an international multicentre cohort study . Elsevier Ltd, United States Br. J. Anaesth.. 14716771. 130 (2) (2023), e217,. doi: 10.1016/j.bja.2022.04.010.
L.A. Evered, M.T.V. Chan, R. Han, M.H.M. Chu, B.P. Cheng, D.A. Scott, K.O. Pryor, D.I. Sessler, R. Veselis, C. Frampton, M. Sumner, A. Ayeni, P.S. Myles, D. Campbell, K. Leslie, T.G. Short, Anaesthetic depth and delirium after major surgery: a randomised clinical trial . Brit. J. Anaesth.. 14716771. 127 (5) (2021), 704-712,. doi: 10.1016/j.bja.2021.07.021.
M.T.V. Chan, T.L. Hedrick, T.D. Egan, P.S. Garcia, S. Koch, P.L. Purdon, M.A. Ramsay, T.E. Miller, M.D. Mcevoy, T.J. Gan, American society for enhanced recovery and perioperative quality initiative joint consensus statement on the role of neuromonitoring in perioperative outcomes: electroencephalography . Lippincott Williams and Wilkins, Hong Kong Anesth. Analg.. 15267598. 130 (5) (2020), 1278-1291,. doi: 10.1213/ANE.0000000000004502.
L. Ding, D.X. Chen, Q. Li, Effects of electroencephalography and regional cerebral oxygen saturation monitoring on perioperative neurocognitive disorders: a systematic review and meta-analysis . BioMed Central Ltd, China BMC Anesthesiol.. 14712253. 20 (1) (2020). doi: 10.1186/s12871-020-01163-y.
M. Sumner, C. Deng, L. Evered, C. Frampton, K. Leslie, T. Short, D. Campbell, Processed electroencephalography-guided general anaesthesia to reduce postoperative delirium: a systematic review and meta-analysis . Brit. J. Anaesth.. 14716771. 130 (2) (2023), e243,. doi: 10.1016/j.bja.2022.01.006.
Y. Sun, F. Ye, J. Wang, P. Ai, C. Wei, A. Wu, W. Xie, Electroencephalography-guided anesthetic delivery for preventing postoperative delirium in adults: an updated meta-analysis . Lippincott Williams and Wilkins, China Anesth. Analg.. 15267598. 131 (3) (2020), 712-719,. doi: 10.1213/ANE.0000000000004746.
J. Montupil, A. Defresne, V. Bonhomme, The raw and processed electroencephalogram as a monitoring and diagnostic tool . J. Cardiothorac. Vasc. Anesth.. 15328422. 33 (2019), S3,. doi: 10.1053/j.jvca.2019.03.038.
M.C. Kim, G.L. Fricchione, E.N. Brown, O. Akeju, Role of electroencephalogram oscillations and the spectrogram in monitoring anaesthesia . BJA Educ.. 20585349. 20 (5) (2020), 166-172, doi: 10.1016/j.bjae.2020.01.004.
P.L. Purdon, K.J. Pavone, O. Akeju, A.C. Smith, A.L. Sampson, J. Lee, D.W. Zhou, K. Solt, E.N. Brown, The Ageing Brain: age-dependent changes in the electroencephalogram during propofol and sevofluranegeneral anaesthesia . Oxford University Press, United States Br. J. Anaesth.. 14716771. 115 (2015), i46,. doi: 10.1093/bja/aev213.
H.A. Kaiser, M. Peus, M.M. Luedi, F. Lersch, V. Krejci, D. Reineke, J. Sleigh, D. Hight, Frontal electroencephalogram reveals emergence-like brain activity occurring during transition periods in cardiac surgery . Brit. J. Anaesth.. 14716771. 125 (3) (2020), 291-297,. doi: 10.1016/j.bja.2020.05.064.
J. Frohlich, L.M. Bird, J. Dell'Italia, M.A. Johnson, J.F. Hipp, M.M. Monti, High-voltage, diffuse delta rhythms coincide with wakeful consciousness and complexity in Angelman syndrome . Oxford University Press, United States Neurosci. Consci.. 20572107. 2020 (1) (2020). doi: 10.1093/NC/NIAA005.
J. Frohlich, M.T. Miller, L.M. Bird, P. Garces, H. Purtell, M.C. Hoener, B.D. Philpot, M.S. Sidorov, W.H. Tan, M.C. Hernandez, A. Rotenberg, S.S. Jeste, M. Krishnan, O. Khwaja, J.F. Hipp, Electrophysiological phenotype in Angelman syndrome differs between genotypes . Elsevier USA, Switzerland Biol. Psychiatry. 18732402. 85 (9) (2019), 752-759,. doi: 10.1016/j.biopsych.2019.01.008.
I. Hagne, I. Witt-Engerstrom, B. Hagberg, EEG development in Rett syndrome. A study of 30 cases . Electroencephalogr. Clin. Neurophysiol.. 00134694. 72 (1) (1989), 1-6, doi: 10.1016/0013-4694(89)90025-4.
E. Niedermeyer, A. Rett, H. Renner, M. Murphy, S. Naidu, J.M. Opitz, J.F. Reynolds, Rett syndrome and the electroencephalogram . Am. J. Med. Genet.. 0148-7299. 25 (S1) (1986), 195-199, doi: 10.1002/ajmg.1320250522.
O.N. Markand, Slow spike-wave activity in EEG and associated clinical features: Often called ‘Lennox’ or ‘Lennox-Gastaut’ syndrome . Neurology. 0028-3878. 27 (8) (1977), , doi: 10.1212/WNL.27.8.746.
M. Matsuura, M. Yoshino, K. Ohta, H. Onda, K. Nakajima, T. Kojima, Clinical significance of diffuse delta EEG activity in chronic schizophrenia . Clin. Electroencephalogr.. 0009-9155. 25 (3) (1994), 115-121, doi: 10.1177/155005949402500309.
M.H. Tulinius, I. Hagne, EEG findings in children and adolescents with mitochondrial encephalomyopathies: a study of 25 cases . Brain Dev.. 03877604. 13 (3) (1991), 167-173, doi: 10.1016/S0387-7604(12)80024-6.
R.N.S. Sachdev, N. Gaspard, J.L. Gerrard, L.J. Hirsch, D.D. Spencer, H.P. Zaveri, Delta rhythm in wakefulness: evidence from intracranial recordings in human beings . J. Neurophysiol.. 15221598. 114 (2) (2015), 1248-1254,. doi: 10.1152/jn.00249.2015.
A.L. Gaskell, D.F. Hight, J. Winders, G. Tran, A. Defresne, V. Bonhomme, A. Raz, J.W. Sleigh, R.D. Sanders, Frontal alpha-delta EEG does not preclude volitional response during anaesthesia: prospective cohort study of the isolated forearm technique . Oxford University Press, New Zealand Br. J. Anaesth.. 14716771. 119 (4) (2017), 664-673,. doi: 10.1093/bja/aex170.
R.D. Sanders, N. Mostert, H. Lindroth, G. Tononi, J. Sleigh, Is consciousness frontal? Two perioperative case reports that challenge that concept . Brit. J. Anaesth.. 14716771. 121 (1) (2018), 330-332,. doi: 10.1016/j.bja.2018.01.010.
B.G. Parsons-Smith, W.H.J. Summerskill, A.M. Dawson, S. Sherlock, The electroencephalograph in liver disease . Lancet. 01406736. 270 (7001) (1957), 867-871, doi: 10.1016/S0140-6736(57)90005-3.
B.J.A. Palanca, T.S. Wildes, Y.S. Ju, S. Ching, M.S. Avidan, Electroencephalography and delirium in the postoperative period . Oxford University Press, United States Br. J. Anaesth.. 14716771. 119 (2) (2017), 294-307,. doi: 10.1093/bja/aew475.
A. Gokyiǧit, A. Caliskan, Diffuse spike-wave status of 9-year duration without behavioral change or intellectual decline . Epilepsia. 15281167. 36 (2) (1995), 210-213, doi: 10.1111/j.1528-1157.1995.tb00982.x.
P. Vuilleumier, F. Assal, O. Blanke, P. Jallon, Distinct behavioral and EEG topographic correlates of loss of consciousness in absences . Lippincott Williams and Wilkins, United States Epilepsia. 00139580. 41 (6) (2000), 687-693,. doi: 10.1111/j.1528-1157.2000.tb00229.x.
J. Frohlich, D. Toker, M.M. Monti, Consciousness among delta waves: a paradox? . Oxford University Press, United States Brain. 14602156. 144 (8) (2021), 2257-2277,. doi: 10.1093/brain/awab095.
S. Vesuna, I.V. Kauvar, E. Richman, F. Gore, T. Oskotsky, C. Sava-Segal, L. Luo, R.C. Malenka, J.M. Henderson, P. Nuyujukian, J. Parvizi, K. Deisseroth, Deep posteromedial cortical rhythm in dissociation . Nature. 14764687. 586 (7827) (2020), 87-94,. doi: 10.1038/s41586-020-2731-9.
C.P. Casey, S. Tanabe, Z. Farahbakhsh, M. Parker, A. Bo, M. White, T. Ballweg, A. Mcintosh, W. Filbey, Y. Saalmann, R.A. Pearce, R.D. Sanders, Distinct EEG signatures differentiate unconsciousness and disconnection during anaesthesia and sleep . Brit. J. Anaesth.. 14716771. 128 (6) (2022), 1006-1018,. doi: 10.1016/j.bja.2022.01.010.
S. Romagnoli, F.A. Lobo, E. Picetti, F.A. Rasulo, C. Robba, B. Matta, Non-invasive technology for brain monitoring: definition and meaning of the principal parameters for the International PRactice on TEChnology neuro-moniToring group (I-PROTECT) . J. Clin. Monit. Comput.. 15732614. (2024). doi: 10.1007/s10877-024-01146-1.
B.G. Fahy, D.F. Chau, The technology of processed electroencephalogram monitoring devices for assessment of depth of anesthesia . Lippincott Williams and Wilkins, United States Anesth. Analg.. 15267598. 126 (1) (2018), 111-117,. doi: 10.1213/ANE.0000000000002331.
N. Marchant, R. Sanders, J. Sleigh, A. Vanhaudenhuyse, M.A. Bruno, J.F. Brichant, S. Laureys, V. Bonhomme, How electroencephalography serves the anesthesiologist . Clin. EEG Neurosci.. 21695202. 45 (1) (2014), 22-32, doi: 10.1177/1550059413509801.
A.A. Klein, T. Meek, E. Allcock, T.M. Cook, N. Mincher, C. Morris, A.F. Nimmo, J.J. Pandit, A. Pawa, G. Rodney, T. Sheraton, P. Young, Recommendations for standards of monitoring during anaesthesia and recovery. Anaesthesia. 0003-2409. 76 (9) (2021), 1212-1223, doi: 10.1111/anae.15501.
S.R. Lewis, M.W. Pritchard, L.J. Fawcett, Y. Punjasawadwong, Bispectral index for improving intraoperative awareness and early postoperative recovery in adults . Cochr. Datab. Syst. Rev.. 1469493X. 2019 (9) (2019). doi: 10.1002/14651858.CD003843.pub4.
J.J. Pandit, J. Andrade, D.G. Bogod, J.M. Hitchman, W.R. Jonker, N. Lucas, J.H. Mackay, A.F. Nimmo, K. O'Connor, E.P. O'Sullivan, R.G. Paul, J.H.M.G. Palmer, F. Plaat, J.J. Radcliffe, M.R.J. Sury, H.E. Torevell, M. Wang, J. Hainsworth, T.M. Cook, J. Armstrong, J. Bird, A. Eddy, W. Harrop-Griffiths, N. Love, R. Mahajan, A. Mallick, I. Barker, A. Kirkpatrick, J. Molodynski, K. Poonnusamy, R. Moonesinghe, D. Weatherill, D. Smith, M. Grocott, M. Humphrey, M. Casserly, S. Drake, J. Rangasami, 5th National Audit Project (NAP5) on accidental awareness during general anaesthesia: Summary of main findings and risk factors . Brit. J. Anaesth.. 14716771. 113 (4) (2014), 549-559,. doi: 10.1093/bja/aeu313.
Y Punjasawadwong, W Chau-in, M Laopaiboon, S Punjasawadwong, Pin-on P. Processed electroencephalogram and evoked potential techniques for amelioration of postoperative delirium and cognitive dysfunction following non-cardiac and non-neurosurgical procedures in adults . Cochrane Database Syst. Rev.. (2018),
C. Koch, M. Massimini, M. Boly, G. Tononi, Neural correlates of consciousness: progress and problems . Nat. Rev. Neurosci.. 14710048. 17 (5) (2016), 307-321,. doi: 10.1038/nrn.2016.22.
D. Hight, M. Kreuzer, G. Ugen, P. Schuller, F. Stuber, J. Sleigh, H.A. Kaiser, Five commercial ‘depth of anaesthesia’ monitors provide discordant clinical recommendations in response to identical emergence-like EEG signals . Brit. J. Anaesth.. 14716771. 130 (5) (2023), 536-545,. doi: 10.1016/j.bja.2022.12.026.
P.S. Glass, M. Bloom, L. Kearse, C. Rosow, P. Sebel, P. Manberg, Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers . Anesthesiology. 00033022. 86 (4) (1997), 836-847, doi: 10.1097/00000542-199704000-00014.
PS Myles, K Leslie, J McNeil, A Forbes, MTV Chan, Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial . Lancet. 01406736. 363 (9423) (2004), 1757-1763, doi: 10.1016/s0140-6736(04)16300-9.
C. Zhang, L. Xu, Y.Q. Ma, Y.X. Sun, Y.H. Li, L. Zhang, C.S. Feng, B. Luo, Z.L. Zhao, J.R. Guo, Y.J. Jin, G. Wu, W. Yuan, Z.G. Yuan, Y. Yue, Bispectral index monitoring prevent awareness during total intravenous anesthesia: a prospective, randomized, double-blinded, multi-center controlled trial . Chin. Med J. 03666999. 124 (22) (2011), 3664-3669,. doi: 10.3760/cma.j.issn.0366-6999.2011.22.012China.
M.S. Avidan, E. Jacobsohn, D. Glick, B.A. Burnside, L. Zhang, A. Villafranca, L. Karl, S. Kamal, B. Torres, M. O'Connor, A.S. Evers, S. Gradwohl, N. Lin, B.J. Palanca, G.A. Mashour, Prevention of intraoperative awareness in a high-risk surgical population . New Engl. J. Med.. 15334406. 365 (7) (2011), 591-600. doi: 10.1056/NEJMoa1100403.
M.S. Avidan, L. Zhang, B.A. Burnside, K.J. Finkel, A.C. Searleman, J.A. Selvidge, L. Saager, M.S. Turner, S. Rao, M. Bottros, C. Hantler, E. Jacobsohn, A.S. Evers, J. Cueto, D. Stamenkovic, E. Safarzadeh, F. Sadiq, B. Hong, H. Kaiser, L. Veremakis, B. Torres, K. Dustman, J. Riddle, M. Rybak, D. Tite, N. Girdner, B. Henrichs, Anesthesia awareness and the bispectral index . New Engl. J. Med.. 15334406. 358 (11) (2008), 1097-1108,. doi: 10.1056/NEJMoa0707361.
G.A. Mashour, A. Shanks, K.K. Tremper, S. Kheterpal, C.R. Turner, S.K. Ramachandran, P. Picton, C. Schueller, M. Morris, J.C. Vandervest, N. Lin, M.S. Avidan, Prevention of intraoperative awareness with explicit recall in an unselected surgical population: a randomized comparative effectiveness trial . Anesthesiology. 15281175. 117 (4) (2012), 717-725, doi: 10.1097/ALN.0b013e31826904a6.
B.A. Fritz, H.R. Maybrier, M.S. Avidan, Intraoperative electroencephalogram suppression at lower volatile anaesthetic concentrations predicts postoperative delirium occurring in the intensive care unit . Brit. J. Anaesth.. 14716771. 121 (1) (2018), 241-248,. doi: 10.1016/j.bja.2017.10.024.
T.S. Wildes, A.M. Mickle, A.B. Abdallah, H.R. Maybrier, J. Oberhaus, T.P. Budelier, A. Kronzer, S.L. McKinnon, D. Park, B.A. Torres, T.J. Graetz, D.A. Emmert, B.J. Palanca, S. Goswami, K. Jordan, N. Lin, B.A. Fritz, T.W. Stevens, E. Jacobsohn, E.M. Schmitt, S.K. Inouye, S. Stark, E.J. Lenze, M.S. Avidan, Effect of electroencephalography-guided anesthetic administration on postoperative delirium among older adults undergoing major surgery the engages randomized clinical trial . J. Am. Med. Assoc.. 15383598. 321 (5) (2019), 473-483,. doi: 10.1001/jama.2018.22005.
D. Hao, B.A. Fritz, D. Saddawi-Konefka, B.J.A. Palanca, Pro-con debate: electroencephalography-guided anesthesia for reducing postoperative delirium . Lippincott Williams and Wilkins, United States Anesth. Analg.. 15267598. 137 (5) (2023), 976-982,. doi: 10.1213/ANE.0000000000006399.
C. Aldecoa, G. Bettelli, F. Bilotta, R.D. Sanders, P. Aceto, R. Audisio, A. Cherubini, C. Cunningham, W. Dabrowski, A. Forookhi, N. Gitti, K. Immonen, H. Kehlet, S. Koch, K. Kotfis, N. Latronico, A.M.J. MacLullich, L. Mevorach, A. Mueller, B. Neuner, S. Piva, F. Radtke, A.R. Blaser, S. Renzi, S. Romagnoli, M. Schubert, A.J.C. Slooter, C. Tommasino, L. Vasiljewa, B. Weiss, F. Yuerek, C.D. Spies, Update of the European Society of Anaesthesiology and Intensive Care Medicine evidence-based and consensus-based guideline on postoperative delirium in adult patients . Eur. J. Anaesthesiol.. 13652346. 41 (2) (2024), 81-108,. doi: 10.1097/EJA.0000000000001876.
R. Gutierrez, J.I. Egana, I. Saez, F. Reyes, C. Briceno, M. Venegas, I. Lavado, A. Penna, Intraoperative low alpha power in the electroencephalogram is associated with postoperative subsyndromal delirium . Frontiers Media S.A., Chile Front. Syst. Neurosci.. 16625137. 13 (2019). doi: 10.3389/fnsys.2019.00056.
Khalifa C. Lenoir C. Robert A. Watremez C. Kahn D. Mastrobuoni S. Aphram G. Ivanoiu A. Bonhomme V. Mouraux A. Momeni M. 2023 Eur. J. Anaesthesiol. 10.1097/EJA.0000000000001895 10 777 787 Intra-operative electroencephalogram frontal alpha-band spectral analysis and postoperative delirium in cardiac surgery
Y.R. Shao, P. Kahali, T.T. Houle, H. Deng, C. Colvin, B.C. Dickerson, E.N. Brown, P.L. Purdon, Low frontal alpha power is associated with the propensity for burst suppression: an electroencephalogram phenotype for avulnerable brain . Anesth. Analg.. 15267598. 131 (5) (2020), 1529-1539,. doi: 10.1213/ANE.0000000000004781.
M. Momeni, S. Meyer, M.A. Docquier, G. Lemaire, D. Kahn, C. Khalifa, M. Rosal Martins, M. Van Dyck, L.M. Jacquet, A. Peeters, C. Watremez, Predicting postoperative delirium and postoperative cognitive decline with combined intraoperative electroencephalogram monitoring and cerebral near-infrared spectroscopy in patients undergoing cardiac interventions . Springer Netherlands, Belgium J. Clin. Monit. Comput.. 15732614. 33 (6) (2019), 999-1009,. doi: 10.1007/s10877-019-00253-8.
P. Laferriere-Langlois, L. Morisson, S. Jeffries, C. Duclos, F. Espitalier, P. Richebe, Depth of anesthesia and nociception monitoring: current state and vision for 2050 . Lippincott Williams and Wilkins, Canada Anesth. Analg.. 15267598. 138 (2) (2024), 295-307,. doi: 10.1213/ANE.0000000000006860.
A. Sangare, M. Quirins, C. Marois, M. Valente, N. Weiss, P. Perez, A. Ben Salah, E. Munoz-Musat, S. Demeret, B. Rohaut, J.D. Sitt, C. Eymond, L. Naccache, Pupil dilation response elicited by violations of auditory regularities is a promising but challenging approach to probe consciousness at the bedside . Sci. Rep.. 20452322. 13 (1) (2023). doi: 10.1038/s41598-023-47806-1.
C. Thornton, R.M. Sharpe, Evoked responses in anaesthesia . BMJ Publishing Group, United Kingdom Br. J. Anaesth.. 00070912. 81 (5) (1998), 771-781,. doi: 10.1093/bja/81.5.771.
F.W. Davies, H. Mantzaridis, G.N.C. Kenny, A.C. Fisher, Middle latency auditory evoked potentials during repeated transitions from consciousness to unconsciousness . Anaesthesia. 00032409. 51 (2) (1996), 107-113, doi: 10.1111/j.1365-2044.1996.tb07694.x.
C. Madler, I. Keller, D. Schwender, E. Poppel, Sensory information processing during general anaesthesia: effect of isoflurane on auditory evoked neuronal oscillations . Br. J. Anaesth.. 00070912. 66 (1) (1991), 81-87, doi: 10.1093/bja/66.1.81.
C. Stoppe, D. Peters, A.V. Fahlenkamp, J. Cremer, S. Rex, G. Schalte, R. Rossaint, M. Coburn, AepEX monitor for the measurement of hypnotic depth in patients undergoing balanced xenon anaesthesia . Brit. J. Anaesth.. 14716771. 108 (1) (2012), 80-88,. doi: 10.1093/bja/aer393.
C. Thornton, C.P.H. Heneghan, M. Navaratnarajah, P.E. Bateman, J.G. Jones, Effect of etomidate on the auditory evoked response in man . Br. J. Anaesth.. 00070912. 57 (6) (1985), 554-561, doi: 10.1093/bja/57.6.554.
S.J. Ge, X.L. Zhuang, Y.T. Wang, Z.D. Wang, H.T. Li, Changes in the rapidly extracted auditory evoked potentials index and the bispectral index during sedation induced by propofol or midazolam under epidural block . Brit. J. Anaesth.. 00070912. 89 (2) (2002), 260-264,. doi: 10.1093/bja/aef187.
S.J. Ge, X.L. Zhuang, Y.T. Wang, Z.D. Wang, S.L. Chen, H.T. Li, Performance of the rapidly extracted auditory evoked potentials index to detect the recovery and loss of wakefulness in anesthetized and paralyzed patients . Acta Anaesthesiol. Scand.. 47 (4) (2003), 466-471, doi: 10.1034/j.1399-6576.2003.00090.x.
H. Litvan, E.W. Jensen, J. Galan, J. Lund, B.E. Rodriguez, S.W. Henneberg, P. Caminal, J.M. Villar Landeira, Comparison of conventional averaged and rapid averaged, autoregressive-based extracted auditory evoked potentials for monitoring the hypnotic level during propofol induction . Anesthesiology. 00033022. 97 (2) (2002), 351-358, doi: 10.1097/00000542-200208000-00011.
H. Litvan, E.W. Jensen, M. Revuelta, S.W. Henneberg, P. Paniagua, J.M. Campos, P. Martinez, P. Caminal, J.M. Villar Landeira, Comparison of auditory evoked potentials and the A-line ARX Index for monitoring the hypnotic level during sevoflurane and propofol induction . Acta Anaesthesiol. Scand.. 00015172. 46 (3) (2002), 245-251, doi: 10.1034/j.1399-6576.2002.t01-1-460304.x.
G. Plourde, Auditory evoked potentials . Best Pract. Res. Clin. Anaesthesiol.. 15216896. 20 (1) (2006), 129-139, doi: 10.1016/j.bpa.2005.07.012.
V. Bonhomme, G. Plourde, P. Meuret, P. Fiset, S.B. Backman, Auditory steady-state response and bispectral index for assessing level of consciousness during propofol sedation and hypnosis . Lippincott Williams and Wilkins, Canada Anesth. Analg.. 00032999. 91 (6) (2000), 1398-1403,. doi: 10.1097/00000539-200012000-00018.
D. Hadzidiakos, S. Petersen, J. Baars, K. Herold, B. Rehberg, Comparison of a new composite index based on midlatency auditory evoked potentials and electroencephalographic parameters with bispectral index (BIS) during moderate propofol sedation . Eur. J. Anaesthesiol.. 13652346. 23 (11) (2006), 931-936, doi: 10.1017/S0265021506001050.
B. Horn, S. Pilge, E.F. Kochs, G. Stockmanns, A. Hock, G. Schneider, A combination of electroencephalogram and auditory evoked potentials separates different levels of anesthesia in volunteers . Lippincott Williams and Wilkins, Germany Anesth. Analg.. 00032999. 108 (5) (2009), 1512-1521,. doi: 10.1213/ane.0b013e3181a04d4c.
C. Jeleazcov, G. Schneider, M. Daunderer, B. Scheller, J. Schuttler, H. Schwilden, The discriminant power of simultaneous monitoring of spontaneous electroencephalogram and evoked potentials as a predictor of different clinical states of general anesthesia . Anesth. Analg.. 00032999. 103 (4) (2006), 894-901, doi: 10.1213/01.ane.0000237231.73261.92.
Moritz T., E.F. Kochs, M. Mueller, S. Kramer, D. Jordan, G. Schneider, G. Erdoes, Machine learning for a combined electroencephalographic anesthesia index to detect awareness under anesthesia . PLoS One. 1932-6203. 15 (8) (2020), e0238249, doi: 10.1371/journal.pone.0238249.
S.V. Notley, S.L. Bell, D.C. Smith, Auditory evoked potentials for monitoring during anaesthesia: a study of data quality . Med. Eng. Phys.. 13504533. 32 (2) (2010), 168-173, doi: 10.1016/j.medengphy.2009.11.006.
Miranda P, C.D Cox, Alexander M, Danev S, J.RT Lakey, Event-related-potential (ERP) markers of traumatic brain injury (TBI) severity and cognitive function - understanding how the brain works and thinks post TBI . J. Syst. Integr. Neurosci.. 20599781. 6 (3) (2020), doi: 10.15761/jsin.1000225.
A.G. Casali, O. Gosseries, M. Rosanova, M. Boly, S. Sarasso, K.R. Casali, S. Casarotto, M.A. Bruno, S. Laureys, G. Tononi, M. Massimini, A theoretically based index of consciousness independent of sensory processing and behavior . Sci. Transl. Med.. 19466242. 5 (198) (2013). doi: 10.1126/scitranslmed.3006294Italy.
F. Ferrarelli, M. Massimini, S. Sarasso, A. Casali, B.A. Riedner, G. Angelini, G. Tononi, R.A. Pearce, Breakdown in cortical effective connectivity during midazolam-induced loss of consciousness . Proc. Natl. Acad. Sci. USA. 0027-8424. 107 (6) (2010), 2681-2686, doi: 10.1073/pnas.0913008107.
O. Gosseries, A. Thibaut, M. Boly, M. Rosanova, M. Massimini, S. Laureys, Assessing consciousness in coma and related states using transcranial magnetic stimulation combined with electroencephalography . Annales Francaises d'Anesthesie et de Reanimation. 17696623. 33 (2) (2014), 65-71,. doi: 10.1016/j.annfar.2013.11.002.
M. Lee, L.R.D. Sanz, A. Barra, A. Wolff, J.O. Nieminen, M. Boly, M. Rosanova, S. Casarotto, O. Bodart, J. Annen, A. Thibaut, R. Panda, V. Bonhomme, M. Massimini, G. Tononi, S. Laureys, O. Gosseries, S.W. Lee, Quantifying arousal and awareness in altered states of consciousness using interpretable deep learning . Nat. Commun.. 20411723. 13 (1) (2022). doi: 10.1038/s41467-022-28451-0.
M. Darracq, C.M. Funk, D. Polyakov, B. Riedner, O. Gosseries, J.O. Nieminen, V. Bonhomme, J.F. Brichant, M. Boly, S. Laureys, G. Tononi, R.D. Sanders, Evoked alpha power is reduced in disconnected consciousness during sleep and anesthesia . Sci. Rep.. 20452322. 8 (1) (2018). doi: 10.1038/s41598-018-34957-9.
C.E. Warnaby, J.W. Sleigh, D. Hight, S. Jbabdi, I. Tracey, Investigation of slow-wave activity saturation during surgical anesthesia reveals a signature of neural inertia in humans . Lippincott Williams and Wilkins, United Kingdom Anesthesiology. 15281175. 127 (4) (2017), 645-657,. doi: 10.1097/ALN.0000000000001759.
D.M. Mathews, L. Clark, J. Johansen, E. Matute, C.V. Seshagiri, Increases in electroencephalogram and electromyogram variability are associated with an increased incidence of intraoperative somatic response . Anesth. Analg.. 00032999. 114 (4) (2012), 759-770, doi: 10.1213/ANE.0b013e3182455ac2.
R.K. Ellerkmann, A. Grass, A. Hoeft, M. Soehle, The response of the composite variability index to a standardized noxious stimulus during propofol-remifentanil anesthesia . Anesth. Analg.. 15267598. 116 (3) (2013), 580-588, doi: 10.1213/ANE.0b013e31827ced18.
M.M. Sahinovic, D.J. Eleveld, A.F. Kalmar, E.H. Heeremans, T. De Smet, C.V. Seshagiri, A.R. Absalom, H.E.M. Vereecke, M.M.R.F. Struys, Accuracy of the composite variability index as a measure of the balance between nociception and antinociception during anesthesia . Lippincott Williams and Wilkins, Netherlands Anesth. Analg.. 15267598. 119 (2) (2014), 288-301,. doi: 10.1213/ANE.0000000000000274.
D.T.J. Liley, N.C. Sinclair, T. Lipping, B. Heyse, H.E.M. Vereecke, M.M.R.F. Struys, Propofol and remifentanil differentially modulate frontal electroencephalographic activity . Lippincott Williams and Wilkins, Australia Anesthesiology. 15281175. 113 (2) (2010), 292-304,. doi: 10.1097/ALN.0b013e3181e3d8a6.
I. Bojak, D.T.J. Liley, Modeling the effects of anesthesia on the electroencephalogram . Phys. Rev. E - Stat. Nonlinear Soft Matter Phys.. 15502376. 71 (4) (2005). doi: 10.1103/PhysRevE.71.041902Australia.
D.T.J. Liley, P.J. Cadusch, M.P. Dafilis, A spatially continuous mean field theory of electrocortical activity . Network: computation in Neural Syst.. 0954898X. 13 (1) (2002), 67-113, doi: 10.1088/0954-898X/13/1/303.
D.T.J. Liley, P.J. Cadusch, M. Gray, P.J. Nathan, Drug-induced modification of the system properties associated with spontaneous human electroencephalographic activity . Phys. Rev. E. 1063651X. 68 (5) (2003), doi: 10.1103/PhysRevE.68.051906.
M. Shoushtarian, M.M. Sahinovic, A.R. Absalom, A.F. Kalmar, H.E.M. Vereecke, D.T.J. Liley, M.M.R.F. Struys, Comparisons of electroencephalographically derived measures of hypnosis and antinociception in response to standardized stimuli during target-controlled propofol-remifentanil anesthesia . Lippincott Williams and Wilkins, Australia Anesth. Analg.. 15267598. 122 (2) (2016), 382-392,. doi: 10.1213/ANE.0000000000001029.
A.J. Aho, L.P. Lyytikainen, A. Yli-Hankala, K. Kamata, V. Jantti, Explaining Entropy responses after a noxious stimulus, with or without neuromuscular blocking agents, by means of the raw electroencephalographic and electromyographic characteristics . Brit. J. Anaesth.. 14716771. 106 (1) (2011), 69-76,. doi: 10.1093/bja/aeq300.
M. Paloheimo, H.L. Edmonds, K. Wirtavuori, T. Tammisto, Assessment of anaesthetic adequacy with upper facial and abdominal wall EMG . Eur. J. Anaesthesiol. 6 (2) (1989), 111-119
H.L. Edmonds, L.J. Couture, M.P.J. Paloheimo, R. Benjamin M. Sr., Objective assessment of opioid action by facial muscle surface electromyography (SEMG) . Progr. Neuropsychopharmacol. Biol. Psychiatr.. 02785846. 12 (5) (1988), 727-738, doi: 10.1016/0278-5846(88)90018-8.
H. Segawa, K. Mori, M. Murakawa, K. Kasai, G. Shirakami, T. Adachi, T. Arai, Isoflurane and sevoflurane augment norepinephrine responses to surgical noxious stimulation in humans . Anesthesiology. 00033022. 89 (6) (1998), 1407-1413, doi: 10.1097/00000542-199812000-00018.
E.W. Jensen, J.F. Valencia, A. Lopez, T. Anglada, M. Agusti, Y. Ramos, R. Serra, M. Jospin, P. Pineda, P. Gambus, Monitoring hypnotic effect and nociception with two EEG-derived indices, qCON and qNOX, during general anaesthesia . Acta Anaesthesiol. Scand.. 13996576. 58 (8) (2014), 933-941,. doi: 10.1111/aas.12359.
M. Struys, L. Versichelen, E. Mortier, D. Ryckaert, J.C. De Mey, C. De Deyne, G. Rolly, Comparison of spontaneous frontal EMG, EEG power spectrum and bispectral index to monitor propofol drug effect and emergence . Acta Anaesthesiol. Scand.. 00015172. 42 (6) (1998), 628-636,. doi: 10.1111/j.1399-6576.1998.tb05293.x.
U. Melia, E. Gabarron, M. Agusti, N. Souto, P. Pineda, J. Fontanet, M. Vallverdu, E.W. Jensen, P. Gambus, Comparison of the qCON and qNOX indices for the assessment of unconsciousness level and noxious stimulation response during surgery . Springer Netherlands, Spain J. Clin. Monit. Comput.. 15732614. 31 (6) (2017), 1273-1281,. doi: 10.1007/s10877-016-9948-z.
J. Gross, A. Schnitzler, L. Timmermann, M. Ploner, Gamma oscillations in human primary somatosensory cortex reflect pain perception . PLoS Biol.. 15457885. 5 (5) (2007), 1168-1173. doi: 10.1371/journal.pbio.0050133Germany.
A. Mouraux, G.D. Iannetti, Nociceptive laser-evoked brain potentials do not reflect nociceptive-specific neural activity . J. Neurophysiol.. 15221598. 101 (6) (2009), 3258-3269,. doi: 10.1152/jn.91181.2008UnitedKingdom.
V Bonhomme, V Llabres, P.-Y. Dewandre, J.F. Brichant, P Hans, Combined use of Bispectral Index™ and A-Line™ Autoregressive Index™ to assess anti-nociceptive component of balanced anaesthesia during lumbar arthrodesis . Br. J. Anaesth.. 00070912. 96 (3) (2006), 353-360, doi: 10.1093/bja/ael004.
Z.G. Zhang, L. Hu, Y.S. Hung, A. Mouraux, G.D. Iannetti, Gamma-band oscillations in the primary somatosensory cortex-A direct and obligatory correlate of subjective pain intensity . J. Neurosci.. 15292401. 32 (22) (2012), 7429-7438,. doi: 10.1523/JNEUROSCI.5877-11.2012.
A. Defresne, M. Harrison, V. Bonhomme, Clinical pertinence and diagnostic accuracy of an evidence-based monitoring system: Custos . Eur. J. Anaesthesiol.. 13652346. 33 (8) (2016), 590-592,. doi: 10.1097/EJA.0000000000000425.
M.H. Kuizenga, H.E.M. Vereecke, A.R. Absalom, C.H. Bucher, L.N. Hannivoort, J.P. van den Berg, L. Schmalz, M.M.R.F. Struys, M. Luginbuhl, Utility of the SmartPilot® View advisory screen to improve anaesthetic drug titration and postoperative outcomes in clinical practice: a two-centre prospective observational trial . Brit. J. Anaesth.. 14716771. 128 (6) (2022), 959-970,. doi: 10.1016/j.bja.2022.02.033.
C. de Tymowski, D. Longrois, P. Montravers, Reducing intraoperative hypotension using a machine learning-derived early warning system . JAMA. 0098-7484. 324 (8) (2020), 806, doi: 10.1001/jama.2020.9049.
M. Pegoli, Z. Zurlo, F. Bilotta, Temperature management in acute brain injury: a systematic review of clinical evidence . Clin. Neurol. Neurosurg.. 03038467. 197 (2020), 106165, doi: 10.1016/j.clineuro.2020.106165.
A. Cariou, J.F. Payen, K. Asehnoune, G. Audibert, A. Botte, O. Brissaud, G. Debaty, S. Deltour, N. Deye, N. Engrand, G. Francony, S. Legriel, B. Levy, P. Meyer, J.C. Orban, S. Renolleau, B. Vigue, L. De Saint Blanquat, C. Mathien, L. Velly, Targeted temperature management in the ICU: guidelines from a French expert panel . Springer Verlag, France Ann. Intensive Care. 21105820. 7 (1) (2017). doi: 10.1186/s13613-017-0294-1.
J. Arrich, N. Schutz, J. Oppenauer, J. Vendt, M. Holzer, C. Havel, H. Herkner, Hypothermia for neuroprotection in adults after cardiac arrest . John Wiley and Sons Ltd, Austria Cochrane Database Syst. Rev.. 14651858. 2023 (5) (2023). doi: 10.1002/14651858.CD004128.pub5.
M.J. Kupersmith, Baseline OCT measurements in the idiopathic intracranial hypertension treatment trial, part ii: correlations and relationship to clinical features . Association for Research in Vision and Ophthalmology Inc., United States Investig. Ophthalmol. Vis. Sci.. 15525783. 55 (12) (2014), 8173-8179,. doi: 10.1167/iovs.14-14961.