Article (Scientific journals)
Full operating parameter recording as an essential component of the reproducibility of laser-tissue interaction and treatments
Parker, Steven; Grzech-Leśniak, Kinga; Cronshaw, Mark et al.
2024In Advances in Clinical and Experimental Medicine, 33 (6), p. 653 - 656
Peer Reviewed verified by ORBi
 

Files


Full Text
653.pdf
Author postprint (153.03 kB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
dentistry; laser; operating parameter; photobiomodulation; surgery; Humans; Laser Therapy; Lasers; Reproducibility of Results; Internal Medicine; Medicine (miscellaneous); Reviews and References (medical); Biochemistry, Genetics and Molecular Biology (all); Genetics (clinical); Pharmacology (medical)
Abstract :
[en] Background. The number and diversity of published peer-reviewed studies in the discipline of laser dentistry have grown considerably during the past 10 years. Objectives. Within primary research, the development of protocols to guide and formulate clinical practice demands precision and ease of reproducibility. Errors in data acquisition and management may become amplified as the applied randomized clinical trials (RCTs) forge new levels of clinical diversity and predictability in the use of laser photonic energy in both ablative (surgical) and sub-ablative (photobiomodulation (PBM) or photodynamic therapy (PDT)) applications. Materials and methods. A comprehensive range of empirical and computational operating parameters must be included in published studies to facilitate the uniformity of power- and time-related values of laser irradiation. Results. Choosing the correct “tissue irradiation parameters” is difficult and depends on the pathology and symptoms, the surface area to be treated, laser wavelength, the thermal relaxation time of each targeted tissue, and controlling penetration depth of the light into tissues. Therefore, to allow the reproducibility of the results, it is recommended that authors mention with the greatest care and clarity the irradiation parameters used in their study. Conclusions. This paper outlines the concerns felt regarding the general shortfalls and proposes a minimum range of laser operating parameters that should be represented in future peer-reviewed publications.
Disciplines :
Dentistry & oral medicine
Author, co-author :
Parker, Steven  ;  Faculty of Health and Life Sciences, De Montfort University, Leicester, United Kingdom
Grzech-Leśniak, Kinga  ;  Laser Laboratory, Department of Dental Surgery, Wroclaw Medical University, Poland ; Polish Sociaty of Laser Society (PTSL), Cracow, Poland
Cronshaw, Mark  ;  Faculty of Health and Life Sciences, De Montfort University, Leicester, United Kingdom
Matys, Jacek  ;  Laser Laboratory, Department of Dental Surgery, Wroclaw Medical University, Poland ; Polish Sociaty of Laser Society (PTSL), Cracow, Poland
Brugnera, Aldo  ;  The IFSC-University of São Paulo, Brazil
Namour, Samir   ;  Université de Liège - ULiège > Département des sciences dentaires
 These authors have contributed equally to this work.
Language :
English
Title :
Full operating parameter recording as an essential component of the reproducibility of laser-tissue interaction and treatments
Publication date :
June 2024
Journal title :
Advances in Clinical and Experimental Medicine
ISSN :
1899-5276
eISSN :
2451-2680
Publisher :
Wroclaw University of Medicine
Volume :
33
Issue :
6
Pages :
653 - 656
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 16 October 2024

Statistics


Number of views
32 (0 by ULiège)
Number of downloads
18 (0 by ULiège)

Scopus citations®
 
4
Scopus citations®
without self-citations
3
OpenCitations
 
0
OpenAlex citations
 
3

Bibliography


Similar publications



Contact ORBi