Implementation of a QA/QC system for untargeted GC×GC analysis
Rodrigues, Anaïs; Haway, Alex; Stefanuto, Pierre-Hugues et al.
2024HTC-18
 

Files


Full Text
Implementation of a QAQC system.pdf
Author postprint (99.52 kB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] Over the past few decades, the field of analytical metabolomics has witnessed continuous growth, particularly in the realm of investigating human health through untargeted analyses. The primary goal has been to detect and identify a broad spectrum of small molecules [1]. The integration of comprehensive two-dimensional gas chromatography (GC×GC) has been a pivotal advancement in facilitating these untargeted analyses [2]. However, as this technology has become an indispensable part of research in this domain, the pressing need for enhancing and standardizing quality assurance (QA) and quality control (QC) practices in untargeted metabolomics has come to the forefront. The metabolomics quality assurance and quality control consortium (mQACC) have played a significant role in developing various QA/QC systems [3]. Despite these efforts, the field continues to face challenges, with a noticeable lack of documentation and standardization, highlighting the importance of addressing these gaps for the advancement of untargeted metabolomics research [4]. In our research, we delved into the establishment of a robust QA/QC system tailored for untargeted analysis, employing two distinct GC×GC-TOFMS systems. Initially, we conducted a thorough comparison of the analytical capabilities of two GC×GC instruments, each equipped with a different modulator system—a cryogenic and a Peltier system. Our investigation involved scrutinizing the analytical performance through the analysis of alkanes (C8-C20) standard solutions and QC solution mix comprising 37 compounds with diverse chemical properties derived from high-quality analytical grade standards. Subsequently, we devised a comprehensive method for monitoring the behavior of 37 different compounds utilizing both systems. Indeed, the comparison between the two systems has revealed that, despite having similar analytical parameters and systems (including the same column set, injection and chromatographic methods, as well as mass spectrometry (MS) systems), some variations on compounds detectability can be observed. This underscores the importance of implementing a robust QA/QC system. The analytical method developed for monitoring the 37 compounds, each exhibiting varying volatility and response due to the diverse chemical functions represented in the panel, has proven effective. Compounds are distributed across the entire 2D chromatogram, demonstrating good distribution and separation in both first and second dimensions over a 35-minute run. In examining the control charts generated for both instruments over the last few months, no deviations for retention times were observed for all compounds, indicating the system's suitability for extended run periods. Additionally, the areas remained stable over months, with an average deviation of 7.73% ± 4.85 for all 37 compounds. This method not only showcased the versatility of the systems but also highlighted its efficacy in handling a diverse range of compounds. Finally, to ensure the reliability and stability of our analytical processes, we implemented a sophisticated QA/QC system featuring control charts. This system meticulously tracked the evolution of retention time and response (area values) for all 37 compounds over six months. Our final goal is to extend this systematic follow-up to encompass all four GC×GC systems within our laboratory. By doing so, we aim to establish a standardized and robust QA/QC framework that will contribute to the precision and reproducibility of our analytical endeavors in the long run for untargeted metabolomics. References: [1] Zhang, A.; Sun, H.; Wang, X. Serum Metabolomics as a Novel Diagnostic Approach for Disease: A Systematic Review. Analytical and Bioanalytical Chemistry. 2012, 404, 1239–1245 [2] Mohler, R. E.; Dombek, K. M.; Hoggard, J. C.; Young, E. T.; Synovec, R. E. Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry Analysis of Metabolites in Fermenting and Respiring Yeast Cells. Analytical Chemistry. 2006, 78(8), 2700–2709 [3] Kirwan, J. A., Gika, H., Beger, R. D., Bearden, D., Dunn, W. B., Goodacre, R., Theodoridis, G., Witting, M., Yu, L-R., Wilson, D. I. Quality assurance and quality control reporting in untargeted metabolic phenotyping: mQACC recommendations for analytical quality management. Metabolomics. 2022, 18(9), 70. [4] Munafò, M. R., Nosek, B.A., Bishop, D.V., Button, K.S., Chambers, C.D., Du Sert, N.P., Simonsohn, U., Wagenmakers, E.-J., Ware, J.J., & Ioannidis, J.P. A manifesto for reproducible science. Nature Human Behaviour, 2017, 1(1), 1–9.
Disciplines :
Chemistry
Author, co-author :
Rodrigues, Anaïs  ;  Université de Liège - ULiège > Molecular Systems (MolSys)
Haway, Alex;  Haute Ecole de la Province de Liège
Stefanuto, Pierre-Hugues  ;  Université de Liège - ULiège > Molecular Systems (MolSys)
Focant, Jean-François  ;  Université de Liège - ULiège > Molecular Systems (MolSys)
Language :
English
Title :
Implementation of a QA/QC system for untargeted GC×GC analysis
Publication date :
30 May 2024
Event name :
HTC-18
Event place :
Louvain, Belgium
Event date :
28-31/05/2024
Audience :
International
Available on ORBi :
since 10 June 2024

Statistics


Number of views
21 (3 by ULiège)
Number of downloads
22 (2 by ULiège)

Bibliography


Similar publications



Contact ORBi