Doctoral thesis (Dissertations and theses)
Amélioration de l’efficacité énergétique des bâtiments publics du sud du Bénin par utilisation des matériaux biosourcés locaux
Kiki, Gratien Jesugo Dieudonné
2023
 

Files


Full Text
Mémoire Thèse_Gratien KIKI_2023.pdf
Author postprint (9.08 MB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Efficacité énergétique; confort thermique; enveloppe du bâtiment; BTC en argile - paille de chiendent; performance hygrothermique; performance énergétique
Abstract :
[fr] L’efficacité énergétique des bâtiments est un moyen fiable de lutte contre le réchauffement climatique de la planète. Dans ce registre, l’enveloppe de bâtiment représente un élément essentiel dans la réduction de la consommation énergétique des bâtiments. Cependant, les enveloppes en matériaux conventionnels généralement utilisées, particulièrement au Bénin, présentent de mauvaises performances hygrothermiques et énergétiques au vu du contexte climatique du pays. Pour y remédier, les matériaux en terre biosourcée se présentent comme une solution efficace et écologique dans la réduction de la consommation énergétique des bâtiments. Ainsi, un matériau en argile – paille de chiendent a été proposé dans la présente étude pour la construction de bâtiments durables. Il se compose en masse par rapport à la masse totale d’échantillon d’environ 55% d’argile, 36% de concassé 0/5, 8% de ciment, 0 à 1,5% de paille de chiendent et 12 à 14% d’eau. Il a été réalisé en blocs de terre comprimée (BTC). Au total, quatre formulations ont été mises en œuvre par variation de la teneur en paille de chiendent. Il s’agit des BTC_8-0 (BTC contenant 8% de ciment et 0% de paille de chiendent), BTC_8-0,5, BTC_8-1 et BTC_8-1,5. La caractérisation physique de ces blocs a principalement permis de déterminer leurs masses volumiques qui varient de 1932 kg/m^3 à 1692 kg/m^3 et leurs porosités accessibles comprises entre 27,1% et 33% lorsque la teneur en paille de chiendent passe respectivement de 0 à 1,5%. Leur employabilité dans l’enveloppe du bâtiment a été vérifiée en effectuant des essais de résistance à la compression et de durabilité sur les matériaux. Pour des teneurs en paille de 0 à 1%, les blocs fabriqués présentent des propriétés mécaniques (résistances aux compressions sèche ‘DCS’ et humide ‘WCS’) supérieures aux seuils normatifs. En revanche, pour le BTC_8-1,5 les DCS et WCS obtenues sont en dessous des limites tolérables dans la construction de bâtiment (DCS=1,76 MPa<2 MPa et WCS=0,56 MPa<1 MPa). Bien que cette dernière formulation présente de bons indices de durabilité (résistance à l’abrasion et à l’érosion), tout comme les autres formulations, elle a été en partie écartée dans la suite de l’étude. La détermination des propriétés thermiques des BTC a permis d’observer une décroissance de la conductivité thermique en fonction de la teneur en paille quel que soit l’humidité des blocs. Par exemple, pour les BTC soumis à une humidité relative de 85% (humidité relative moyenne de l’air dans la région d’étude), les conductivités thermiques mesurées varient de 0,82 W/m.K à 0,67 W/m.K pour les teneurs en paille allant de 0 à 1,5%. Sur le plan hygrique, la présence dominante de la kaolinite dans l’argile et sa stabilisation physique avec le concassé 0/5 ont limité le taux d’absorption d’eau des blocs. A 88% d’humidité relative, les teneurs en humidité d’équilibre sont égales à 2,92% pour le BTC_8-0 et 2,6% pour le BTC_8-1. Avec des capacités tampons d’humidité allant de 1,98 (BTC_8-0) à 2,14 g/m^2.%RH (BTC_8-1), les blocs se sont montrés relativement plus hygroscopiques que les matériaux conventionnels de construction. Par ailleurs, les performances hygrothermiques et énergétiques des blocs ont été évaluées à travers des simulations WUFI un bâtiment de bureaux situé dans la ville de Cotonou au Bénin. A cet effet, une enquête de confort réalisée auprès des occupants dudit bâtiment a permis de déterminer les conditions de confort intérieur à simuler que sont : une température de confort de 26,1°C et une humidité relative comprise entre 40 et 70%. Ainsi, le remplacement de l’enveloppe conventionnelle du bâtiment d’étude par une enveloppe en BTC argile – paille de chiendent a permis des économies respectives de 3 et 8,2% des charges de déshumidification et de climatisation du bureau simulé. Pour finir, les comportements affichés par les BTC en argile – paille de chiendent lors des simulations ont été remarqués pendant des expérimentations de transfert couplé de chaleur et d’humidité à travers des parois en argile – paille de chiendent et en blocs de bétons creux en chambre climatique.
[en] The energy efficiency of buildings is a reliable way to fight global warming. In this context, the building envelope is an essential element in reducing the energy consumption of buildings. However, the envelopes in conventional materials generally used, particularly in Benin, present poor hygrothermal and energetic performances considering the climatic context of the country. To remedy this, biosourced earth materials are an effective and ecological solution in reducing the energy consumption of buildings. This being the case, a clay - quack grass straw material was proposed in the present study for the construction of sustainable buildings. It consists of about 55% clay, 36% crushed 0/5, 8% cement, 0 to 1.5% couch grass straw and 12 to 14% water in relation to the total sample mass. It was made of compressed earth blocks (CEB). A total of four formulations were implemented by varying the content of quackgrass straw. These were CEB_8-0, CEB_8-0.5, CEB_8-1 and CEB_8-1.5. The physical characterisation of these blocks mainly determined their densities which varied from 1932 kg/m^3 to 1692 kg/m^3 and their accessible porosities ranging from 27.1% to 33% when the quackgrass straw content increased from 0 to 1.5% respectively. Their suitability in the building envelope was verified by performing compressive strength and durability tests on the materials. For straw contents from 0 to 1% the manufactured blocks present mechanical properties (dry compressive strength ' DCS ' and wet compressive strength ' WCS') higher than the normative thresholds. On the other hand, for the CEB_8-1.5 the obtained DCS and WCS are below the tolerable limits in building construction (DCS=1.76 MPa<2 MPa and WCS=0.56 MPa<1 MPa). Although the latter formulation shows good durability indices (abrasion and erosion resistance), as do the other formulations, it was partially discarded in the rest of the study. The determination of the thermal properties of the CEB allowed to observe a decrease of the thermal conductivity according to the content of straw whatever is the humidity of the blocks. For example, for the CEB subjected to a relative humidity of 85% (average relative humidity of the air in the study area) the thermal conductivity measured vary from 0.82 W/m.K to 0.67 W/m.K for straw contents ranging from 0 to 1.5%. On the hygric level, the dominant presence of kaolinite in the clay and its physical stabilization with the 0/5 crushed clay limited the water absorption rate of the blocks. At 88% relative humidity, the equilibrium moisture contents are equal to 2.92% for the CEB_8-0 and 2.6% for the CEB_8-1. With moisture buffering capacities ranging from 1.98 (CEB_8-0) to 2.14 g/m^2.%RH (CEB_8-1), the blocks were shown to be relatively more hygroscopic than conventional building materials. In addition, the hygrothermal and energetic performances of the blocks were evaluated through WUFI simulations on an office building located in the city of Cotonou in Benin. To this end, a comfort survey conducted with the occupants of the building has determined the conditions of indoor comfort to be simulated which are: a comfort temperature of 26.1 ° C and a relative humidity between 40 and 70%. Thus, the replacement of the conventional envelope of the study building by an envelope made of BTC clay - quackgrass straw allowed savings of 3 and 8.2% respectively of the dehumidification and air conditioning loads of the simulated office. Finally, the behaviours displayed by the clay - quackgrass CEB during the simulations were noticed during experiments of coupled heat and humidity transfer through clay - quackgrass walls and hollow concrete blocks in a climatic chamber.
Disciplines :
Energy
Author, co-author :
Kiki, Gratien Jesugo Dieudonné ;  Université de Liège - ULiège > Sphères
Language :
French
Title :
Amélioration de l’efficacité énergétique des bâtiments publics du sud du Bénin par utilisation des matériaux biosourcés locaux
Alternative titles :
[en] Improvement of the energy efficiency of public buildings in southern Benin through the use of local bio-sourced materials
Original title :
[fr] Amélioration de l’efficacité énergétique des bâtiments publics du sud du Bénin par utilisation des matériaux biosourcés locaux
Defense date :
29 March 2023
Number of pages :
226
Institution :
ULiège - Université de Liège [Faculté de Sciences], Arlon, Belgium
Université d'Abomey-Calavi [Sciences de l'Ingénieur], Abomey-Calavi, Benin
Degree :
Doctorat en Sciences
Cotutelle degree :
Doctorat en Energétique et Mécanique
Promotor :
Andre, Philippe ;  Université de Liège - ULiège > Département des sciences et gestion de l'environnement (Arlon Campus Environnement) > Building Energy Monitoring and Simulation (BEMS)
HOUNGAN, Comlan Aristide;  UNSTIM - Université Nationale des Sciences, Technologies, Ingénierie et Mathématiques [Bénin] > Génie Mécanique et Energétique
Courard, Luc  ;  Université de Liège - ULiège > Département ArGEnCo > Matériaux de construction non métalliques du génie civil
MESSAN, Adamah;  2iE - Institut International d’Ingénierie de l’Eau et de l’Environnement [Burkina-Faso] > Génie Civil
ROMAIN, Remond;  UL - Université de Lorraine [FR] > Ecole Nationale Supérieure des Technologies et Industries du Bois
KOUCHADE, Adéyèmi Clément;  UAC - Université d'Abomey-Calavi [Bénin] > Faculté des Sciences et Techniques
ANJORIN, Malahimi;  UAC - Université d'Abomey-Calavi [Bénin] > Génie Mécanique et Energétique
President :
Romain, Anne-Claude  ;  Université de Liège - ULiège > Département des sciences et gestion de l'environnement (Arlon Campus Environnement) > Surveillance de l'environnement
Development Goals :
11. Sustainable cities and communities
13. Climate action
Funders :
ARES CCD - Académie de Recherche et d'Enseignement Supérieur. Coopération au Développement [BE]
Available on ORBi :
since 20 May 2023

Statistics


Number of views
286 (13 by ULiège)
Number of downloads
492 (3 by ULiège)

Bibliography


Similar publications



Contact ORBi