[en] This paper presents a new proposal for beam-column interaction formulae initially based on second-order in-plane elastic theory, as an alternative to those proposed in the Eurocode 3 pre-standard [1]. It has been derived according to the following requirements: theoretical background, clear physical meaning, consistency with the other related formulae of Eurocode 3 and accuracy. Besides that, the suggested formulae cover all required continuities: between the cross-section classes, from plasticity to elasticity as slenderness and axial force increase, and continuity between all the individual stability member checks and cross-section verifications. Further to the presentation of the formulae and their background, the good agreement of the proposal is shown through an extensive comparison with more than 15,000 results of finite element numerical simulations. (C) 2002 Civil-Comp Ltd. and Elsevier Science Ltd. All rights reserved.
Disciplines :
Civil engineering Computer science
Author, co-author :
Boissonnade, N.
Jaspart, Jean-Pierre ; Université de Liège - ULiège > Département Argenco : Secteur MS2F > Adéquat. struct. aux exig. de fonct.& perfor. techn.-écon.
Muzeau, J. P.
Villette, M.
Language :
English
Title :
Improvement of the interaction formulae for beam columns in Eurocode 3
Publication date :
November 2002
Journal title :
Computers and Structures
ISSN :
0045-7949
Publisher :
Pergamon-Elsevier Science Ltd, Oxford, United Kingdom
scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.
Bibliography
Design of steel structures. Part 1-1: General rules and rules for buildings (1993) ENV 1993-1-1
Massonnet, C., 40 Years of research on beam-columns in steel (1976) Solid Mech. Arch., 1 (1)
Villette, M., Boissonnade, N., Muzeau, J.P., Jaspart, J.P., (2000) Development of a comprehensive formula for the design of beam-columns, , Internal report, Baudin-Châteauneuf: LERMES-CUST, University of Liege
Maquoi, R., Boissonnade, N., Muzeau, J.P., Jaspart, J.P., Villette, M., The interaction formulae for beam-columns: A new step of a yet long story (2001) Proceedings of the 2001 SSRC Annual Technical Session and Meeting, pp. 63-88
Bureau, A., Galéa, Y., Jaspart, J.P., Maquoi, R., Muzeau, J.P., Villette, M., Proposal for a revision of Eurocode 3 (1999) TC8-ECCS meeting, , Timisoara
(1988) Teil 1, Stahlbauten, Bemessung und Konstruktion, , Berlin: Beuth Verlag GMBH
Maquoi, R., Rondal, J., (1982) Sur la force portante des poutres colonnes, , Annales des travaux publics de Belgique
Villette, M., Considérations sur le flambement, proposition de révision de l'Eurocode 3 (1997) Constr. Métall., 3, pp. 15-38
Ofner, R., (1997) Traglasten Von Stäben aus Stahl bei Druck und Biegung, , PhD thesis, Institut für Stahlbau, Holzbau und Fläschentragwerke, Technische Universität Graz, Fakultät für Bauingenieurwesen
Boissonnade, N., (1999) Contribution au développement de nouvelles formules pouréléments comprimés et fléchis au sens de l'Eurocode 3, , Diploma work, MSM Liège, CUST, Blaise Pascal University
Lescouarc'h, Y., Capacité de résistance d'une section soumise à divers types de sollicitations (1997) Constr. Métall., 2, pp. 3-17
TC8-ECCS ad hoc working group on beam-columns. Background information on the "level 2" beam-column design formulae and evaluation of its accuracy (2000) TC8-ECCS meeting, , London
Similar publications
Sorry the service is unavailable at the moment. Please try again later.
This website uses cookies to improve user experience. Read more
Save & Close
Accept all
Decline all
Show detailsHide details
Cookie declaration
About cookies
Strictly necessary
Performance
Strictly necessary cookies allow core website functionality such as user login and account management. The website cannot be used properly without strictly necessary cookies.
This cookie is used by Cookie-Script.com service to remember visitor cookie consent preferences. It is necessary for Cookie-Script.com cookie banner to work properly.
Performance cookies are used to see how visitors use the website, eg. analytics cookies. Those cookies cannot be used to directly identify a certain visitor.
Used to store the attribution information, the referrer initially used to visit the website
Cookies are small text files that are placed on your computer by websites that you visit. Websites use cookies to help users navigate efficiently and perform certain functions. Cookies that are required for the website to operate properly are allowed to be set without your permission. All other cookies need to be approved before they can be set in the browser.
You can change your consent to cookie usage at any time on our Privacy Policy page.