Physical Therapy, Sports Therapy and Rehabilitation; Pediatrics, Perinatology and Child Health
Abstract :
[en] ("[en] PURPOSE: Assess the ability of the Kinect to capture movement and posture of people with spinal muscular atrophy (SMA) during completion of 14 items of the Motor Function Measure, a validated functional rating scale for people with neuromuscular diseases.
METHODS: Multicenter feasibility study in which Motor Function Measure items were scored as usual by the participant's therapist during the completion (Score-T) while another therapist scored items based only on the visualization of digital data collected using the Kinect (Score-D). Agreement and disagreement were investigated.
RESULTS: Twenty people with SMA type 2 or 3 were participants; 142 items were recorded and analyzed. There was 31.7% agreement between Score-T and Score-D for participants with SMA type 2, and 76.2% for those with SMA type 3.
CONCLUSIONS: The results prevent us from considering the use of Kinect capture to deduce an automated scoring, but this device may be of interest to highlight potential compensations.","[en] ","")
Disciplines :
Pediatrics Neurology
Author, co-author :
Vincent-Genod, Dominique; Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, France > Service de Médecine Physique et de Réadaptation Pédiatrique l'Escale
Rippert, Pascal; Hospices Civils de Lyon, France > Pôle Santé Publique > Recherche Epidémiologie clinique
Coton, Justine; Université Grenoble Alpes, G-SCOP, Grenoble, France > CNRS, Grenoble INP > Institute of Engineering
Le Goff, Laure; Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, France > Service de Médecine Physique et de Réadaptation Pédiatrique l'Escale
Barriere, Aurélie; Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, France > Service de Médecine Physique et de Réadaptation Pédiatrique l'Escale ; Hôpital de la Croix Rousse, Hospices Civils de Lyon, France > Centre de Référence des Maladies Neuromusculaires
Berruyer, Anne; Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, France > Service de Médecine Physique et de Réadaptation Pédiatrique l'Escale
Bernard, Marjorie; Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, France > Service de Médecine Physique et de Réadaptation Pédiatrique l'Escale
Garde, Camille; Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, France > Service de Médecine Physique et de Réadaptation Pédiatrique l'Escale
Gutierrez-Garcia, Marta; Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, France > Service de Médecine Physique et de Réadaptation Pédiatrique l'Escale
Gilabert, Stéphanie; GH Pitié-Salpêtrière, Paris, France > Institut de Myologie
Gomes-Lisboade-Souza, Adriana; Université Grenoble Alpes, G-SCOP, Grenoble, France > CNRS, Grenoble INP > Institute of Engineering
Daron, Aurore ; Centre Hospitalier Universitaire de Liège - CHU > > Service de pédiatrie
Servais, Laurent ; Centre Hospitalier Universitaire de Liège - CHU > > Service de pédiatrie ; GH Pitié-Salpêtrière, Paris, France > Institut de Myologie
Thomann, Guillaume; Université Grenoble Alpes, G-SCOP, Grenoble, France > CNRS, Grenoble INP > Institute of Engineering
Vuillerot, Carole; Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, France > Service de Médecine Physique et de Réadaptation Pédiatrique l'Escale ; Université Claude Bernard Lyon 1 and CNRS UMR 5310-INSERM U1217, France
Verhaart IEC, Robertson A, Leary R, et al. A multi-source approach to determine SMA incidence and research ready population. J Neurol. 2017;264(7):1465-1473. doi:10.1007/s00415-017-8549-1.
Munsat TL, Davies KE. International SMA consortium meeting (26-28 June 1992, Bonn, Germany). Neuromuscul Disord. 1992;2(5):423-428. doi:10.1016/S0960-8966(06)80015-5.
Finkel R, Bertini E, Muntoni F, Mercuri E; ENMC SMA Workshop Study Group. 209th ENMC International Workshop: outcome measures and clinical trial readiness in spinal muscular atrophy 7-9 November 2014, Heemskerk, The Netherlands. Neuromuscul Disord. 2015;25(7): 593-602. doi:10.1016/j.nmd.2015.04.009.
Messina S, Sframeli M. New treatments in spinal muscular atrophy: positive results and new challenges. J Clin Med. 2020;9(7):2222. doi:10.3390/jcm9072222.
Kirschner J, Butoianu N, Goemans N, et al. European ad-hoc consensus statement on gene replacement therapy for spinal muscular atrophy. Eur J Paediatr Neurol. 2020;28:38-43. doi:10.1016/j.ejpn.2020.07.001.
Iftikhar M, Frey J, Shohan MdJ, Malek S, Mousa SA. Current and emerging therapies for Duchenne muscular dystrophy and spinal muscular atrophy. Pharmacol Ther. 2021;220:107719. doi:10.1016/j.pharmthera.2020.107719.
Bérard C, Payan C, Hodgkinson I, Fermanian J; MFM Collaborative Study Group. A motor function measure for neuromuscular diseases. Construction and validation study. Neuromuscul Disord. 2005;15(7): 463-470.
de Lattre C, Payan C, Vuillerot C, et al. Motor function measure: validation of a short form for young children with neuromuscular diseases. Arch Phys Med Rehabil. 2013;94(11):2218-2226. doi:10.1016/j.apmr.2013.04.001.
Jacqmin P, Gieschke R, Delor I, et al. Mathematical disease progression modeling in type 2/3 spinal muscular atrophy. Muscle Nerve. 2018; 58(4):528-535. doi:10.1002/mus.26178.
Vuillerot C, Payan C, Iwaz J, Ecochard R, Bérard C; MFM Spinal Muscular Atrophy Study Group. Responsiveness of the motor function measure in patients with spinal muscular atrophy. Arch Phys Med Rehabil. 2013;94(8):1555-1561.
Servais L. Video games to measure outcome for children with neuromuscular disorders. Dev Med Child Neurol. 2019;62(3):266. doi:10.1111/dmcn.14231.
Rocha AP, Choupina HMP, Vilas-Boas M do C, Fernandes JM, Cunha JPS. System for automatic gait analysis based on a single RGB-D camera. PLoS One. 2018;13(8):e0201728.
Bonnechère B, Sholukha V, Omelina L, Van Sint Jan S, Jansen B. 3D analysis of upper limbs motion during rehabilitation exercises using the KinectTM sensor: development, laboratory validation and clinical application. Sensors. 2018;18(7):2216.
Lopez N, Perez E, Tello E, Rodrigo A, Valentinuzzi ME. Statistical validation for clinical measures: repeatability and agreement of KinectTM-based software. BioMed Res Int. 2018;2018:6710595. doi:10.1155/2018/6710595.
Clark RA, Mentiplay BF, Hough E, Pua YH. 3-dimensional cameras and skeleton pose tracking for physical function assessment: a review of uses, validity, current developments and Kinect alternatives. Gait Posture. 2019;68:193-200. doi:10.1016/j.gaitpost.2018.11.029.
Cai L, Ma Y, Xiong S, Zhang Y. Validity and reliability of upper limb functional assessment using the Microsoft Kinect V2 sensor. Appl Bionics Biomech. 2019;2019:7175240. doi:10.1155/2019/7175240.
Scano A, Chiavenna A, Malosio M, Molinari Tosatti L, Molteni F. Kinect V2 implementation and testing of the reaching performance scale for motor evaluation of patients with neurological impairment. Med Eng Phys. 2018;56:54-58. doi:10.1016/j.medengphy.2018.04.005.
Mousavi Hondori H, Khademi M. A review on technical and clinical impact of Microsoft Kinect on physical therapy and rehabilitation. J Med Eng. 2014;2014:846514. doi:10.1155/2014/846514.
Chabanon A, Seferian AM, Daron A, et al. Prospective and longitudinal natural history study of patients with type 2 and 3 spinal muscular atrophy: baseline data NatHis-SMA study. PloS One. 2018; 13(7):e0201004. doi:10.1371/journal.pone.0201004.
Lowes LP, Alfano LN, Yetter BA, et al. Proof of concept of the ability of the Kinect to quantify upper extremity function in dystrophinopathy. PLoS Curr. 2013;5. doi:10.1371/currents.md. 9ab5d872bbb944c6035c9f9bfd314ee2.
Lowes LP, Alfano LN, Crawfis R, et al. Reliability and validity of active-seated: an outcome in dystrophinopathy. Muscle Nerve. 2015;52(3):356-362. doi:10.1002/mus.24557.
Obdrzálek S, Kurillo G, Ofli F, et al. Accuracy and robustness of Kinect pose estimation in the context of coaching of elderly population. Annu Int Conf IEEE Eng Med Biol Soc. 2012;2012:1188-1193. doi:10.1109/EMBC.2012.6346149.
Otte K, Kayser B, Mansow-Model S, et al. Accuracy and reliability of the Kinect Version 2 for clinical measurement of motor function. PLoS One. 2016;11(11):e0166532. doi:10.1371/journal.pone.0166532.
Ma M, Proffitt R, Skubic M. Validation of a Kinect V2 based rehabilitation game. PLoS One. 2018;13(8):e0202338. doi:10.1371/journal.pone.0202338.
Hu G, Wang W, Chen B, et al. Concurrent validity of evaluating knee kinematics using Kinect system during rehabilitation exercise. Med Nov Technol Devices. 2021;11:100068. doi:10.1016/j.medntd.2021.100068.
Galna B, Barry G, Jackson D, Mhiripiri D, Olivier P, Rochester L. Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson's disease. Gait Posture. 2014;39(4):1062-1068. doi:10.1016/j.gaitpost.2014.01.008.
Mortazavi F, Nadian-Ghomsheh A. Stability of Kinect for range of motion analysis in static stretching exercises. PLoS One. 2018;13(7): e0200992. doi:10.1371/journal.pone.0200992.
Webster D, Celik O. Systematic review of Kinect applications in elderly care and stroke rehabilitation. J Neuroengineering Rehabil. 2014;11:108. doi:10.1186/1743-0003-11-108.
Da Gama A, Fallavollita P, Teichrieb V, Navab N. Motor rehabilitation using Kinect: a systematic review. Games Health J. 2015;4(2):123-135. doi:10.1089/g4h.2014.0047.
Blaschek A, Hesse N, Warken B, et al. Quantitative motion measurements based on markerless 3D full-body tracking in children with SMA highly correlate with standardized motor assessments. J Neuromuscul Dis. 2022;9(1):121-128. doi:10.3233/JND-200619.
Yeung LF, Yang Z, Cheng KCC, Du D, Tong RKY. Effects of camera viewing angles on tracking kinematic gait patterns using Azure Kinect, Kinect v2 and Orbbec Astra Pro v2. Gait Posture. 2021;87:19-26. doi:10.1016/j.gaitpost.2021.04.005.