[en] The following code describes different control algorithms for external Venetian blinds and solar screens. The algorithms are based on a multi-criteria approach, and applies the ISO/DIS 52016-3 to balance visual and thermal comfort, heating and artificial lighting energy needs, and users’ satisfaction. They integrate multiple parameters related to internal and external conditions: daylight, glare, operative temperature, room occupancy, and vertical irradiance on the window. The control algorithms are applied and validated on a DesignBuilder model.
The code reported is for the Venetian blinds case. In order to apply to the solar screen case, it is sufficient to substitute “Shade_Status_Exterior_Blind” with “Shade_Status_Exterior_Shade”.
Research center :
Sustainable Building Design (SBD) Lab
Disciplines :
Architecture
Author, co-author :
Bertini, Aurora
Attia, Shady ; Université de Liège - ULiège > Urban and Environmental Engineering
Language :
English
Title :
Control algorithm for external solar shadings (Venetian blinds and roller blinds)
Publication date :
22 October 2022
Publisher :
Sustainable Building Design Lab, Liege, Belgium
Technical description :
Code to control external solar shadings - Venetian blinds and solar screens