optimal power flow; nonlinear programming; interior-point method
Abstract :
[en] This paper analyzes the ability of the Multiple Centrality Corrections
(MCC) interior point algorithm to solve various classical optimal power
flow (OPF) variants, namely: the minimization of generation cost, the
minimization of active power losses, the maximization of power system
loadability and the minimization of the amount of load curtailment.
The performances of the MCC approach are assessed with respect to the
predictor-corrector algorithm, which is widely recognized as the best
interior point method based optimizer to date. Illustrative examples on
three test systems up to 300 buses are provided.
Disciplines :
Electrical & electronics engineering
Author, co-author :
Capitanescu, Florin ; Université de Liège - ULiège > Dép. d'électric., électron. et informat. (Inst.Montefiore) > Systèmes et modélisation