Article (Scientific journals)
Comparison of two portable clinical analyzers to one stationary analyzer for the determination of blood gas partial pressures and blood electrolyte concentrations in horses.
Kirsch, Katharina; Detilleux, Johann; Serteyn, Didier et al.
2019In PLoS ONE, 14 (2), p. 0211104
Peer Reviewed verified by ORBi
 

Files


Full Text
Kirsch et al 2019.pdf
Publisher postprint (1.72 MB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] Portable blood gas analyzers are used to facilitate diagnosis and treatment of disorders related to disturbances of acid-base and electrolyte balance in the ambulatory care of equine patients. The aim of this study was to determine whether 2 portable analyzers produce results in agreement with a stationary analyzer. Blood samples from 23 horses hospitalized for various medical reasons were included in this prospective study. Blood gas analysis and electrolyte concentrations measured by the portable analyzers VetStat and epoc were compared to those produced by the cobas b 123 analyzer via concordance analysis, Passing-Bablok regression and Bland-Altman analysis. Limits of agreement indicated relevant bias between the VetStat and cobas b 123 for partial pressure of oxygen (pO2; 27.5-33.8 mmHg), sodium ([Na+]; 4.3-21.6 mmol/L) and chloride concentration ([Cl-]; 0.3-7.9 mmol/L) and between the epoc and cobas b 123 for pH (0.070-0.022), partial pressure of carbon dioxide (pCO2; 3.6-7.3 mmHg), pO2 (36.2-32.7 mmHg) and [Na+] (0.38.1 mmol/L). The VetStat analyzer yielded results that were in agreement with the cobas b 123 analyzer for determination of pH, pCO2, bicarbonate ([HCO3-]) and potassium concentration [K+], while the epoc analyzer achieved acceptable agreement for [HCO3-] and [K+]. The VetStat analyzer may be useful in performing blood gas analysis in equine samples but analysis of [Na+], [Cl-] and pO2 should be interpreted with caution. The epoc delivered reliable results for [HCO3-] and [K+], while results for pH, pCO2, pO2 and [Na+] should be interpreted with caution.
Disciplines :
Veterinary medicine & animal health
Author, co-author :
Kirsch, Katharina ;  Université de Liège - ULiège > FARAH
Detilleux, Johann ;  Université de Liège - ULiège > Dpt. de gestion vétérinaire des Ressources Animales (DRA) > Génétique quantitative
Serteyn, Didier  ;  Université de Liège - ULiège > Dép. clinique des animaux de compagnie et des équidés (DCA) > Anesthésiologie gén. et pathologie chirurg. des grds animaux
Sandersen, Charlotte  ;  Université de Liège - ULiège > Dép. clinique des animaux de compagnie et des équidés (DCA) > Anesthésiologie et réanimation vétérinaires
Language :
English
Title :
Comparison of two portable clinical analyzers to one stationary analyzer for the determination of blood gas partial pressures and blood electrolyte concentrations in horses.
Publication date :
2019
Journal title :
PLoS ONE
eISSN :
1932-6203
Publisher :
Public Library of Science, United States - California
Volume :
14
Issue :
2
Pages :
e0211104
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 20 November 2020

Statistics


Number of views
53 (8 by ULiège)
Number of downloads
27 (2 by ULiège)

Scopus citations®
 
13
Scopus citations®
without self-citations
11
OpenCitations
 
10

Bibliography


Similar publications



Contact ORBi