A randomized cross-over comparison of the hemodynamic response to intermittent hemodialysis and continuous hemofiltration in ICU patients with acute renal failure.
Misset, Benoît; Timsit, J. F.; Chevret, S.et al.
1996 • In Intensive Care Medicine, 22 (8), p. 742-6
[en] OBJECTIVE: To compare the hemodynamic response of ICU patients with acute renal failure of a 24-h continuous arteriovenous hemofiltration (CAVH) and that of patients with a 4-h intermittent hemodialysis (HD). DESIGN: Cross-over randomized clinical trial. The two periods to be compared were a 24-h CAVH and the 24-h encompassing a 4-h HD. These two periods were separated by a 24-h wash-out period. SETTING: Ten bed medicosurgical ICU of a tertiary care center in Paris, France. PATIENTS: Inclusion criterion was the requirement of replacement therapy for acute renal failure in patients already submitted to mechanical ventilation. INTERVENTIONS: CAVH was performed with Ringers' lactate used for restitution and infused before the hemofilter. The ultrafiltrate output was maintained at around 15 ml/min. HD was performed with a bicarbonate-buffered dialysate. MEAN OUTCOME MEASURES: Mean arterial pressure (MAP), use of adrenergic drugs, and change in body weight during each period. RESULTS: Twenty-seven consecutive patients were included, 15 CAVH-HD and 12HD-CAVH. CAVH and HD allowed the same metabolic efficacy. No hemodynamic parameter (MAP, amount of adrenergic drugs, change in body weight) differed between the two methods. CONCLUSIONS: CAVH is equivalent to HD in terms of MAP and the use of vasopressive drugs and fluids. Establishing the superiority of CAVH would require carefully controlled studies assessing either outcome or changes in tissue oxygenation.
Disciplines :
Anesthesia & intensive care
Author, co-author :
Misset, Benoît ; Centre Hospitalier Universitaire de Liège - CHU > Service de Soins Intensifs
Timsit, J. F.
Chevret, S.
Renaud, B.
Tamion, F.
Carlet, J.
Language :
English
Title :
A randomized cross-over comparison of the hemodynamic response to intermittent hemodialysis and continuous hemofiltration in ICU patients with acute renal failure.
Kramer P, Kaufhold, G. Grôhne HJ et al (1980) Management of anuric intensive care patients with arteriovenous hemofiltration. Int J Artif Organs 3:225-230
Baldamus CA, Ernst W, Frei U et al (1982) Sympathetic and hemodynamic response to volume removal during different forms of renal replacement therapy. Nephron (Basel) 31:324
Hills M, Armitage P (1979) The two-period change-over design and its use in clinical trials. Br J Clin Pharmacol 8:7-20
Le Gall JR, Loirat P, Alperovitch A et al (1984) A simplified acute physiology score for ICU patients. Crit Care Med 12:975-977
Groeneveld ABJ (1990) Septic shock and multiple organ failure: treatment with hemofiltration? Intensive Care Med 16:489-490
Davenport A, Will E, Davidson AM (1993) Improved cardiovascular stability during continuous modes of renal replacement therapy in critically ill patients with acute hepatic and renal failure. Crit Care Med 21:328-338
Gutierrez, G. Palizas F, Doglio G et al (1992) Gastric intramucosal pH as a therapeutic index of tissue oxygenation in critically ill patients. Lancet 339:195-199
Reinhart K, Hannemann L, Meier-Hellmann A et al (1994) Monitoring of oxygen transport and tissue oxygenation in septic shock. In: Reinhart K. Eyrich K, Sprung C (eds) Sepsis: current perspectives in pathophysiology and therapy. Springer, Berlin Heidelberg New York, pp 181-190
Bellomo R, McGrath B, Boyce N et al (1994) Effect of continuous venovenous hemofiltration with dialysis on hormone and catecholamine clearance in critically ill patients with acute renal failure. Crit Care Med 22:833-837