Article (Scientific journals)
A randomized cross-over comparison of the hemodynamic response to intermittent hemodialysis and continuous hemofiltration in ICU patients with acute renal failure.
Misset, Benoît; Timsit, J. F.; Chevret, S. et al.
1996In Intensive Care Medicine, 22 (8), p. 742-6
Peer Reviewed verified by ORBi
 

Files


Full Text
PUBMED 99.pdf
Publisher postprint (460.43 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Acute Kidney Injury/physiopathology/therapy; Adrenergic Agents/therapeutic use; Body Weight; Cross-Over Studies; Hemodynamics; Hemofiltration; Humans; Renal Dialysis/methods; Statistics, Nonparametric
Abstract :
[en] OBJECTIVE: To compare the hemodynamic response of ICU patients with acute renal failure of a 24-h continuous arteriovenous hemofiltration (CAVH) and that of patients with a 4-h intermittent hemodialysis (HD). DESIGN: Cross-over randomized clinical trial. The two periods to be compared were a 24-h CAVH and the 24-h encompassing a 4-h HD. These two periods were separated by a 24-h wash-out period. SETTING: Ten bed medicosurgical ICU of a tertiary care center in Paris, France. PATIENTS: Inclusion criterion was the requirement of replacement therapy for acute renal failure in patients already submitted to mechanical ventilation. INTERVENTIONS: CAVH was performed with Ringers' lactate used for restitution and infused before the hemofilter. The ultrafiltrate output was maintained at around 15 ml/min. HD was performed with a bicarbonate-buffered dialysate. MEAN OUTCOME MEASURES: Mean arterial pressure (MAP), use of adrenergic drugs, and change in body weight during each period. RESULTS: Twenty-seven consecutive patients were included, 15 CAVH-HD and 12HD-CAVH. CAVH and HD allowed the same metabolic efficacy. No hemodynamic parameter (MAP, amount of adrenergic drugs, change in body weight) differed between the two methods. CONCLUSIONS: CAVH is equivalent to HD in terms of MAP and the use of vasopressive drugs and fluids. Establishing the superiority of CAVH would require carefully controlled studies assessing either outcome or changes in tissue oxygenation.
Disciplines :
Anesthesia & intensive care
Author, co-author :
Misset, Benoît ;  Centre Hospitalier Universitaire de Liège - CHU > Service de Soins Intensifs
Timsit, J. F.
Chevret, S.
Renaud, B.
Tamion, F.
Carlet, J.
Language :
English
Title :
A randomized cross-over comparison of the hemodynamic response to intermittent hemodialysis and continuous hemofiltration in ICU patients with acute renal failure.
Publication date :
1996
Journal title :
Intensive Care Medicine
ISSN :
0342-4642
eISSN :
1432-1238
Publisher :
Springer, Heidelberg, Germany
Volume :
22
Issue :
8
Pages :
742-6
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 21 February 2020

Statistics


Number of views
47 (0 by ULiège)
Number of downloads
0 (0 by ULiège)

Scopus citations®
 
116
Scopus citations®
without self-citations
113
OpenCitations
 
88

Bibliography


Similar publications



Contact ORBi