Article (Scientific journals)
Four-stage (low-)flow modulation comprehensive gas chromatography-quadrupole mass spectrometry for the determination of recently-highlighted cosmetic allergens
Tranchida, P. Q.; Maimone, M.; Franchina, Flavio et al.
2016In Journal of Chromatography. A, 1439, p. 144-151
Peer Reviewed verified by ORBi
 

Files


Full Text
51-JCA 1439 (2016) 144–151-allergens.pdf
Publisher postprint (1.15 MB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Comprehensive two-dimensional gas chromatography; Flow modulation; Fragrance allergens; Perfumes; Quadrupole mass spectrometry; Allergens; Chromatography; Cosmetics; Fragrances; Mass spectrometry; Modulation; Odors; Smoke detectors; Spectrometry; Absolute quantification; Analyte identifications; Flow modulations; Gas chromatography-quadrupole mass spectrometry; Linear retention indices; Gas chromatography; Article; Calibration; Gas Chromatography-Mass Spectrometry; Ions; Perfume
Abstract :
[en] The present research is based on the development and use of a flow-modulation (FM) comprehensive two-dimensional gas chromatography-quadrupole mass spectrometry (GC × GC-qMS) method for the determination of recently-highlighted (by the Scientific Committee on Consumer Safety) fragrance allergens (54) in cosmetics. FM GC × GC-qMS conditions were finely tuned to generate flow conditions (≈7 mL min-1) compatible with the qMS system used. Six-point calibration curves, over the range 1, 5, 10, 20, 50, 100 mg L-1, were constructed for the 54 target allergens, with satisfactory linearity observed in all cases. Absolute quantification was performed by using extracted ions; target analyte identification was performed through measurement of ion ratios (qualifier/quantifier), full-scan MS database matching and the use of linear retention indices. Additional analytical figures of merit subjected to measurement were intra-day repeatability, accuracy at the 25 and 5 mg L-1 levels, and limits of detection and quantification. The number of data points per peak, along with mass spectral skewing, was also subjected to evaluation. Finally, the FM GC × GC-qMS method was used not only for the quantification of target allergens in five commercial perfumes, but also for general qualitative profiling. © 2015 Elsevier B.V.
Disciplines :
Chemistry
Author, co-author :
Tranchida, P. Q.;  Scienze del Farmaco e Prodotti per la Salute Department, University of Messina, viale Annunziata, Messina, 98168, Italy
Maimone, M.;  Scienze del Farmaco e Prodotti per la Salute Department, University of Messina, viale Annunziata, Messina, 98168, Italy
Franchina, Flavio ;  Université de Liège - ULiège > Département de chimie (sciences) > Chimie analytique, organique et biologique
Bjerk, T. R.;  Instituto de Química, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
Zini, C. A.;  Instituto de Química, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
Purcaro, Giorgia  ;  Université de Liège - ULiège > Agronomie, Bio-ingénierie et Chimie (AgroBioChem) > Chimie des agro-biosystèmes
Mondello, L.;  Scienze del Farmaco e Prodotti per la Salute Department, University of Messina, viale Annunziata, Messina, 98168, Italy, Chromaleont s.r.l., C/o Scienze del Farmaco e Prodotti per la Salute Dept., University of Messina, viale Annunziata, Messina, 98168, Italy, University Campus Bio-Medico of Rome, Via Álvaro del Portillo, 21, Roma, 00128, Italy
Language :
English
Title :
Four-stage (low-)flow modulation comprehensive gas chromatography-quadrupole mass spectrometry for the determination of recently-highlighted cosmetic allergens
Publication date :
2016
Journal title :
Journal of Chromatography. A
ISSN :
0021-9673
eISSN :
1873-3778
Publisher :
Elsevier
Volume :
1439
Pages :
144-151
Peer reviewed :
Peer Reviewed verified by ORBi
Funders :
CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico [BR]
Available on ORBi :
since 17 January 2019

Statistics


Number of views
32 (2 by ULiège)
Number of downloads
0 (0 by ULiège)

Scopus citations®
 
33
Scopus citations®
without self-citations
30
OpenCitations
 
29

Bibliography


Similar publications



Contact ORBi