Yuce, M. R.; Department of Electrical Engineering and Computer Systems Engineering, Biomedical Integrated Circuits and Sensors Laboratory, Monash University, Clayton, Melbourne, VIC 3800, Australia
Redouté, Jean-Michel ; Université de Liège - ULiège > Dép. d'électric., électron. et informat. (Inst.Montefiore) > Systèmes microélectroniques intégrés
Language :
English
Title :
Implanted Wireless Biotelemetry
Publication date :
2014
Main work title :
Implantable Bioelectronics - Devices, Materials and Applications
Yuce, M.R. and Khan, J. (2011) Wireless Body Area Networks: Technology, Implementation and Applications, Pan Stanford Publishing ISBN: 978-981-431-6712.
Webster, J.G. (1998) Medical Instrumentation Application and Design, John Wiley & Sons, Inc., Hoboken, NJ.
Yuce, M.R. (2010) Implementation of wireless body area networks for healthcare systems. Sens. Actuators, A:Phys., 162, 116-129.
Yuce, M.R. and Dissanayake, T. (2012) Easy-to-swallow wireless telemetry. IEEE Microwave Mag., 13, 90-101.
Liu, W. et al. (2005) Implantable biomimetic microelectronic systems design. IEEE Eng. Med. Biol. Mag., 24, 66.
Bradley, P. (2006) An ultra low power, high performance medical implant communication system (MICS) transceiver for implantable devices. Proceeding of the IEEE Biomedical Circuits and Systems Conference, pp. 158-116.
Yuce, M.R., Ho, C.K., and Chae, M. (2009) Wideband communication for implant-able and wearable systems. IEEE Trans. Microwave Theory Tech., 57, 2597-2604.
Troyk, P.R. and DeMichele, G.A. (2003) Inductively-coupled power and data link for neural prostheses using a class-E oscillator and FSK modulation Proceeding of the IEEE International Conference, Engineering in Medicine and Biology Society, September, 2003, pp. 3376-3379.
Zhou, M., Yuce, M.R., and Liu, W. (2008) A non-coherent DPSK data receiver with interference cancellation for dual-band transcutaneous telemetries. IEEE J. Solid State Circuits, 43, 2203-2012.
Li, P. and Bashirullah, R. (2007) A wireless power interface for rechargeable battery operated medical implants. IEEE Trans. Circuits Syst. II, 54, 912-916.
Laskovski, A. and Yuce, M.R. (2011) A MICS telemetry implant powered by a 27MHz ISM inductive link. The International Conference of the IEEE Engineering in Medicine and Biology Society, August-September 2011, pp. 290-2912.
Lim, H., Yoon, Y., Lee, C., Park, I., Song, B., and Cho, J.H. (2005) Implementation of a transcutaneous charger for fully implantable middle ear hearing device, IEEE-EMBS 2005. 27th Annual International Conference of the, Engineering in Medicine and Biology Society, pp. 6813-6816.
Wang, G., Liu, W., Sivaprakasam, M., Zhou, M., Weiland, J. D., and Humayun, M.S.A (2006) Dual band wireless power and data telemetry for retinal prosthesis. EMBS '06. 28th Annual International Conference of the IEEE, pp. 4392-4395.
Zimmerman, M.D., Chaimanonart, N., and Young, D.J. (2006) In Vivo RF powering for advanced biological research. 28th Annual International Conference of the IEEE, 2006 Engineering in Medicine and Biology Society, pp. 2506-2509.
Chae, M., Yang, Z., Yuce, M.R., Hoang, L., and Liu, W. (2009) A 128-channel 6mW wireless neural recording ic with spike feature extraction and UWB transmitter. IEEE Trans. Neural Syst. Rehabil. Eng., 17, 312-321.
Harrison, R.R. (2008) The design of integrated circuits to observe brain activity. Proc. IEEE, 96, 1203-1216.
Inanlou, F. and Ghovanloo, M. (2011) Wideband near-field data transmission using pulse harmonic modulation. IEEE Trans. Circuits Syst. I, 58, 186-195.
Babiloni, F. et al. (2007) Simultaneous tracking of multiple brains activity with high resolution EEG hyperscannings. Proceeding of the IEEE International Conference on Functional Biomedical Imaging, NFSI-ICFBI, October 12-14, pp. 196-199.
Farshchi, S., Pesterev, A., Nuyujukian, P., Modi, I., and Judy, J. (2006) A TinyOS-enabled MICA2-based wireless neural interface. IEEE Trans. Biomed. Eng., 53, 1416.
Modarreszadeh, M., and Schmidt, R.N. (1997) Wireless, 32-channel, EEG and epilepsy monitoring system. Proceeding of the 19th International Conference IEEE/EMBS, Chicago, IL, October 30-November 2, p. 1157.
Sodagar, A.M., Wise, K.D., and Najafi, K. (2007) A fully integrated mixed-signal neural processor for implantable multichannel cortical recording. IEEE Trans. Biomed. Eng., 54 (6), 1075-1088.
Sodagar, A.M., Perlin, G.E., Yao, Y., Najafi, K., and Wise, K.D. (2009) An implantable 64-channel wireless microsystem for single-unit neural recording. IEEE J. Solid-State Circuits, 44, 2591-2604.
Gao, H., Walker, R.M., Nuyujukian, P., Makinwa, K.A.A., Shenoy, K.V., Murmann, B., and Meng, T.H. (2012) HermesE: A 96-channel full data rate direct neural interface in 0.13 um CMOS. IEEE J. Solid State Circuits., 47 (4), 1043-1054.
Yin, M., Borton, D.A., Aceros, J., Patterson, W.R., and Nurmikko, A.V. (2012) A 100-channel hermetically sealed implantable device for wireless neurosensing applications. Proceeding of the IEEE International Symposium on Circuits and Systems, May 2012, pp. 2629-2632.
Lee, S.B., Lee, H.-M., Kiani, M., Jow, U.-M., and Ghovanloo, M. (2010) An inductively powered scalable 32-channel wireless neural recording system-on-achip for neuroscience applications. IEEE Trans. Biomed. Circuits Syst., 4, 360-371.
Givenimaging (2013) http://www.givenimaging.com/ (accessed 11 September 2013).
Puers, R., Carta, R., and Thone, J. (2011) Wireless power and data transmission strategies for next-generation capsule endoscopes. J. Micromech. Microeng., 21, 054008.
Otto, K.J., Ludwig, K.A., and Kipke, D.R. (2012) Acquiring brain signals from within the brain, in Brain-Computer Interfaces: Principles and Practice, Oxford University Press.
Robinson, D.A. (1968) The electrical properties of metal microelectrodes. Proc. IEEE, 56 (6), 1065-1071.
Bhandari, R., Negi, S., and Solzbacher, F. (2010) Wafer-scale fabrication of penetrating neural microelectrode arrays. Biomed. Microdevices (Springer), 12 (5), 797-807.
Najafi, K., Wise, K., and Mochizuki, T. (1985) A high-yield IC-compatible multichannel recording array. IEEE Trans. Electron Devices, 22, 230-241.
Hoogerwerf, A.C. and Wise, K.D. (1994) A three-dimensional microelectrode array for chronic neural recording. IEEE Trans. Biomed. Eng., 41 (12), 1136-1146.
Sivaprakasam, M., Liu, W., Wang, J.S., Weiland, D., and Humayun, M.S. (2005) Architecture Tradeoffs in High-Density Microstimulators for Retinal Prosthesis. IEEE Transactions on Circuits and Systems I, 52 (12).
Jones, K.E. and Normann, R.A. (1997) An advanced demultiplexing system for physiological stimulation. IEEE Trans. Biomed. Eng., 44 (12), 1210-1220.
Ghovanloo, M. and Najafi, K. (2005) A compact large voltage-compliance high output-impedance programmable current source for implantable microstimulators. IEEE Trans. Biomed. Eng., 52 (1), 97-105.
Noorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., and Ortmanns, M. (2012) A neural stimulator frontend with high-voltage compliance and programmable pulse shape for epiretinal implants. IEEE J. Solid-State Circuits, 47 (1), 244-256.
DeMarco, S.C., Liu, W., Singh, P.R., Lazzi, G., Humayun, M.S., and Weiland, J.D. (2003) An arbitrary waveform stimulus circuit for visual prosthesis using a low-area multibias DAC. IEEE J. Solid-State Circuits, 38 (10), 1679-1690.
Ghovanloo, M. and Najafi, K. (2007) A wireless implantable multichannel microstimulating system-on-a-chip with modular architecture. IEEE Trans. Neural Syst. Rehabil. Eng., 15 (3), 449-457.
Suaning, G. and Lovell, N.H. (2001) CMOS neurostimulation ASIC with 100 channels, scalable output, and bidirectional radio-frequency telemetry. IEEE Trans. Biomed. Eng., 48 (2), 248-260.
Liu, W., Vichienchom, K., Clements, M., DeMarco, S.C., Hughes, C., McGucken, E., Humayun, M.S., de Juan, E., Weiland, J.D., and Greenberg, R. (2000) A neuro-stimulus chip with telemetry unit for retinal prosthetic device. IEEE J. Solid-State Circuits, 35 (10), 1487-1497.
Sivaprakasam, M., Liu, W., Humayun, M. S., and Weiland, J. D. (2005) A variable range bi-phasic current stimulus driver circuitry for an implantable retinal prosthetic device, IEEE Journal of Solid-State Circuits, 40, (3), pp. 763-771.
Ortmanns, M., Rocke, A., Gehrke, M., and Tiedtke, H.-J. (2007) A 232-channel epiretinal stimulator ASIC. IEEE J. Solid-State Circuits, 42 (12), 2946-2959.
Sit, J.-J. and Sarpeshkar, R. (2007) A low-power blocking-capacitor-free charge-Balanced electrode-stimulator chip with less than 6 nA DC Error for 1-mA full-scale stimulation. IEEE Trans. Biomed. Circuits Syst., 3, 184-192.
Harrison, R.R., Watkins, P.T., Kier, R.J., Lovejoy, R.O., Black, D.J., Greger, B., and Solzbacher, F. (2007) A low-power integrated circuit for a wireless 100-electrode neural recording system. IEEE J. Solid-State Circuits, 42 (1), 123.
López, C.M., Welkenhuysen, M., Musa, S., Eberle, W., Bartic, C., Puers, R., and Gielen, G. (2012) Towards a noise prediction model for in vivo neural recording, International Conference of the IEEE Engineering in Medicine and Biology Society, 2012.
Wattanapanitch, W., Fee, M., and Sarpeshkar, R. (2007) An energy-efficient micropower neural recording amplifier. IEEE Trans. Biomed. Circuits Syst., 1 (2), 136-147.
Bohorquez, J.L., Yip, M., Chandrakasan, A.P., and Dawson, J.L. (2011) A biomedical sensor interface with a sinc filter and interference cancellation. IEEE J. Solid-State Circuits, 46 (4), 746-756.
Harrison, R.R. and Charles, C. (2003) A low-power low-noise cmos amplifier for neural recording applications. IEEE J. Solid-State Circuits, 38 (6), 958-965.
Chae, M.S., Yang, Z., and Liu, W. (2010) Microelectronics of recording, stimulation, and wireless telemetry for neuroprosthetics: design and optimization, in Implantable Neural Prostheses Part II, Springer, New York, pp. 253-330.
Mohseni, P. and Najafi, K. (2004) A fully integrated neural recording amplifier with DC input stabilization. IEEE Trans. Biomed. Eng., 51 (5), 832-837.
Dagtekin, M., Liu, W., and Bashirullah, R. (2001) A multi channel chopper modulated neural recording system. IEEE International Conference of the Engineering in Medicine and Biology Society, 2001.
Yazicioglu, R.F., Merken, P., Puers, R., and Van Hoof, C. (2007) A 60 uW 60 nV/ sqrt(Hz) readout front-end for portable biopotential acquisition systems. IEEE J. Solid-State Circuits, 42 (5), 1100-1110.
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., and Kelly, A. (2007) A 2 uW 100 nV/sqrt(Hz) chopper-stabilized instrumentation amplifier for chronic measurement of neural field potentials. IEEE J. Solid-State Circuits, 42 (12), 2934-2945.