Article (Scientific journals)
Technical and methodological requirements for reliable haemodynamic measurements in the unsedated calf.
Amory, Hélène; Linden, Annick; Desmecht, Daniel et al.
1992In Veterinary Research Communications, 16 (5), p. 391-401
Peer Reviewed verified by ORBi
 

Files


Full Text
AmoryH_VetResComm_1992.pdf
Publisher postprint (2.34 MB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Calf; cardiac catheterization; conscious haemodynamics; technique
Abstract :
[en] The purpose of this study was (1) to evaluate the technical and methodological problems associated with invasive haemodynamic measurements in unsedated cattle; (2) to assess the reproducibility of such measurements both within and between days; and (3) to compare the values with those previously reported. Twenty-one healthy calves, aged from 5.5 to 12 months, were studied. The central venous, the right ventricular, the pulmonary arterial, the pulmonary capillary wedge and the systemic arterial pressures were obtained by means of fluid-filled catheters, and the cardiac output was measured by the thermodilution technique. The heart rate, the stroke volume, the pulmonary and systemic vascular resistances and the pulmonary and systemic ventricular workloads were calculated. An adverse reaction, consisting of severe pulmonary hypertension, tachycardia, tachypnoea and transient weakness, occurred in 7 calves during the catheterization procedures. Such a reaction might be due to a local reflex induced by stimulation of mechano-receptors by the catheter tip. It should be avoided by reducing the manipulation of the catheter as much as possible and by inflating the tip of the balloon when moving it forwards. A comparison of the vascular pressures with those previously reported was difficult because of methodological or technical limitations, such as, for instance, a lack of standardization of the baseline. The reproducibility of the haemodynamic measurements obtained was satisfactory, in contrast to previous studies performed in conscious animals. This was attributed to our animals being better trained to the experimental conditions and emphasizes the importance of reducing mental stress in obtaining reliable haemodynamic measurements in unsedated and potentially uncooperative animals.
Disciplines :
Anatomy (cytology, histology, embryology...) & physiology
Veterinary medicine & animal health
Author, co-author :
Amory, Hélène ;  Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Médecine interne des équidés
Linden, Annick  ;  Université de Liège - ULiège > Département des maladies infectieuses et parasitaires > Santé et pathologies de la faune sauvage
Desmecht, Daniel ;  Université de Liège - ULiège > Département de morphologie et pathologie > Pathologie spéciale et autopsies
Rollin, Frédéric ;  Université de Liège - ULiège > Département clinique des animaux de production (DCP) > Médecine interne des équidés, des ruminants et des porcs
Mc Entee, Kathleen ;  Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Pathologie médicale des petits animaux
Lekeux, Pierre ;  Université de Liège - ULiège > Département de sciences fonctionnelles > Physiologie - Doyen de la Faculté de Médecine vétérinaire
Language :
English
Title :
Technical and methodological requirements for reliable haemodynamic measurements in the unsedated calf.
Publication date :
1992
Journal title :
Veterinary Research Communications
ISSN :
0165-7380
Publisher :
Kluwer Academic Publishers, Dordrecht, Netherlands
Volume :
16
Issue :
5
Pages :
391-401
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 09 September 2009

Statistics


Number of views
40 (5 by ULiège)
Number of downloads
1 (1 by ULiège)

Scopus citations®
 
14
Scopus citations®
without self-citations
14
OpenCitations
 
11

Bibliography


Similar publications



Contact ORBi