Article (Scientific journals)
Use of the impulse oscillometry system for testing pulmonary function during methacholine bronchoprovocation in horses.
Van Erck, Emmanuelle; Votion, Dominique; Kirschvink, Nathalie et al.
2003In American Journal of Veterinary Research, 64 (11), p. 1414-1420
Peer Reviewed verified by ORBi
 

Files


Full Text
VanErckE_AJVMA_2003.pdf
Publisher postprint (844.81 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Airway Obstruction/physiopathology/veterinary; Animals; Bronchial Provocation Tests/methods/veterinary; Horse Diseases/physiopathology; Horses/physiology; Kinetics; Oscillometry; Reference Values; Respiratory Function Tests/veterinary
Abstract :
[en] OBJECTIVE: To compare sensitivity of the impulse oscillometry system (IOS) with that of the conventional reference technique (CRT; ie, esophageal balloon method) for pulmonary function testing in horses. ANIMALS: 10 horses (4 healthy; 6 with recurrent airway obstruction [heaves] in remission). PROCEDURE: Healthy horses (group-A horses) and heaves-affected horses (group-B horses) were housed in a controlled environment. At each step of a methacholine bronchoprovocation test, threshold concentration (TC(2SD); results in a 2-fold increase in SD of a value) and sensitivity index (SI) were determined for respiratory tract system resistance (R(rs)) and respiratory tract system reactance (X(rs)) at 5 to 20 Hz by use of IOS and for total pulmonary resistance (RL) and dynamic lung compliance (C(dyn)), by use of CRT. RESULTS: Bronchoconstriction resulted in an increase in R(rs) at 5 Hz (R(5Hz)) and a decrease in X(rs) at all frequencies. Most sensitive parameters were X(rs) at 5 Hz (X(5Hz)), R(5Hz), and R(5Hz):R(10Hz) ratio; RL and the provocation concentration of methacholine resulting in a 35% decrease in dynamic compliance (PC(35)C(dyn)) were significantly less sensitive than these IOS parameters. The TC(2SD) for X(rs) at 5 and 10 Hz was significantly lower in group-B horses, compared with group-A horses. The lowest TC(2SD) was obtained for X(5Hz) in group-B horses and R(5Hz) in group-A horses. CONCLUSIONS AND CLINICAL RELEVANCE: In contrast to CRT parameters, IOS parameters were significantly more sensitive for testing pulmonary function.The IOS provides a practical and noninvasive pulmonary function test that may be useful in assessing subclinical changes in horses.
Disciplines :
Veterinary medicine & animal health
Author, co-author :
Van Erck, Emmanuelle ;  Université de Liège - ULiège > Département clinique des animaux de production (DCP) > Département clinique des animaux de production (DCP)
Votion, Dominique  ;  Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Anesthésiologie gén. et pathologie chirurg. des grds animaux
Kirschvink, Nathalie
Art, Tatiana ;  Université de Liège - ULiège > Département de sciences fonctionnelles > Phys. neuro-muscul., de l'effort - Méd. sport. des animaux
Lekeux, Pierre ;  Université de Liège - ULiège > Département de sciences fonctionnelles > Physiologie - Doyen de la Faculté de Médecine vétérinaire
Language :
English
Title :
Use of the impulse oscillometry system for testing pulmonary function during methacholine bronchoprovocation in horses.
Publication date :
2003
Journal title :
American Journal of Veterinary Research
ISSN :
0002-9645
eISSN :
1943-5681
Publisher :
American Veterinary Medical Association, Schaumburg, United States - Illinois
Volume :
64
Issue :
11
Pages :
1414-1420
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 09 September 2009

Statistics


Number of views
115 (2 by ULiège)
Number of downloads
0 (0 by ULiège)

Scopus citations®
 
27
Scopus citations®
without self-citations
22
OpenCitations
 
23

Bibliography


Similar publications



Contact ORBi