electromyography; muscle; activation level; signal processing; scapular plane; kinematics
Abstract :
[en] Normalization of the electromyography (EMG) signal is often performed relatively to maximal voluntary activations (MVA) obtained during maximum isometric voluntary contraction (MVIC). The first aim was to provide an inter-session reproducible protocol to normalize the signal of eight shoulder muscles. The protocol should also lead to a level of activation >90% of MVA for >90% of the volunteers. The second aim was to evaluate the influence of the method used to extract the MVA from the EMG envelope on the normalized EMG signal. Thirteen volunteers performed 12 MVICs twice (one-week interval). Several time constants (100 ms to 2 s) were compared when extracting the MVA from the EMG envelope. The EMG activity was also acquired during an arm elevation. Our results show that a combination of nine MVIC tests was required to meet our requirements including reproducibility. Both the number of MVIC tests and the size of the time constant influence the normalized EMG signal during the dynamic activity (variations up to 15%). A time constant of 1 s was a good compromise to extract the MVA. These findings are valuable to improve the reproducibility of EMG signal normalization.
Research Center/Unit :
Laboratoire d'Analyse du Mouvement Humain (LAMH)
Disciplines :
Human health sciences: Multidisciplinary, general & others
Author, co-author :
Schwartz, Cédric ; Université de Liège > Département des sciences de la motricité > Kinésithérapie générale et réadaptation
Tubez, François ; Université de Liège > Département des sciences de la motricité > Kinésithérapie générale et réadaptation
WANG, François-Charles ; Centre Hospitalier Universitaire de Liège - CHU > Service de médecine de l'appareil locomoteur
Croisier, Jean-Louis ; Université de Liège > Département des sciences de la motricité > Kinésithérapie générale et réadaptation
Bruls, Olivier ; Université de Liège > Département d'aérospatiale et mécanique > Laboratoire des Systèmes Multicorps et Mécatroniques
Denoël, Vincent ; Université de Liège > Département ArGEnCo > Analyse sous actions aléatoires en génie civil
Forthomme, Bénédicte ; Université de Liège > Département des sciences de la motricité > Rééducation du membre supérieur
Language :
English
Title :
Normalizing shoulder EMG: an optimal set of maximum isometric voluntary contraction tests considering reproducibility
scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.
Bibliography
Atkinson, G., Nevill, A., Statistical methods for assessing measurement error (Reliability) in variables relevant to sports medicine. Sport. Med. 26 (1998), 217–238, 10.2165/00007256-199826040-00002.
Bao, S., Mathiassen, S.E., Winkel, J., Normalizing upper trapezius EMG amplitude: Comparison of different procedures. J. Electromyogr. Kinesiol. 5 (1995), 251–257, 10.1016/1050-6411(95)00005-4.
Barbero, M., Merletti, R., Rainoldi, A., Atlas of Muscle Innervation Zones. 2012, Springer Milan, 10.1007/978-88-470-2463-2.
Bartlett, J.W., Frost, C., Reliability, repeatability and reproducibility: Analysis of measurement errors in continuous variables. Ultrasound Obstet. Gynecol. 31 (2008), 466–475, 10.1002/uog.5256.
Boettcher, C.E., Ginn, K.A., Cathers, I., Standard maximum isometric voluntary contraction tests for normalizing shoulder muscle EMG. J. Orthop. Res. 26 (2008), 1591–1597, 10.1002/jor.20675.
Burden, A., How should we normalize electromyograms obtained from healthy participants? What we have learned from over 25 years of research. J. Electromyogr. Kinesiol. 20 (2010), 1023–1035, 10.1016/j.jelekin.2010.07.004.
Castelein, B., Cagnie, B., Parlevliet, T., Danneels, L., Cools, A., Optimal normalization tests for muscle activation of the levator scapulae, pectoralis Minor, and rhomboid major: an electromyography study using maximum voluntary isometric contractions. Arch. Phys. Med. Rehabil. 96 (2015), 1820–1827, 10.1016/j.apmr.2015.06.004.
Dal Maso, F., Marion, P., Begon, M., Optimal combinations of isometric normalization tests for the production of maximum voluntary activation of the shoulder muscles. Arch. Phys. Med. Rehabil. 97 (2016), 1542–1551, 10.1016/j.apmr.2015.12.024.
De Luca, C.J., The use of surface electromyography in biomechanics. J. Appl. Biomech. 13 (1993), 135–163.
Ekstrom, R.A., Soderberg, G.L., Donatelli, R.A., Normalization procedures using maximum voluntary isometric contractions for the serratus anterior and trapezius muscles during surface EMG analysis. J. Electromyogr. Kinesiol. 15 (2005), 418–428, 10.1016/j.jelekin.2004.09.006.
Fauth, M.L., Petushek, E.J., Feldmann, C.R., Hsu, B.E., Garceau, L.R., Lutsch, B.N., Ebben, W.P., Reliability of surface electromyography during maximal voluntary isometric contractions, jump landings, and cutting. J. Strength Cond. Res. 24 (2010), 1131–1137, 10.1519/JSC.0b013e3181cc2353.
Fischer, S.L., Belbeck, A.L., Dickerson, C.R., The influence of providing feedback on force production and within-participant reproducibility during maximal voluntary exertions for the anterior deltoid, middle deltoid, and infraspinatus. J. Electromyogr. Kinesiol. 20 (2010), 68–75, 10.1016/j.jelekin.2009.01.007.
Fischer, S.L., Grewal, T.J., Wells, R., Dickerson, C.R., Effect of bilateral versus unilateral exertion tests on maximum voluntary activity and within-participant reproducibility in the shoulder. J. Electromyogr. Kinesiol. 21 (2011), 311–317, 10.1016/j.jelekin.2010.05.002.
Halaki, M., Ginn, K.A., Normalization of EMG signals: to normalize or not to normalize and what to normalize to?. Naik, G.R., (eds.) Computational Intelligence in Electromyography Analysis - A Perspective on Current Applications and Future Challenges, 2012, InTech, 175–194, 10.5772/49957.
Johnson, V.L., Halaki, M., Ginn, K.A., The use of surface electrodes to record infraspinatus activity is not valid at low infraspinatus activation levels. J. Electromyogr. Kinesiol. 21 (2011), 112–118, 10.1016/j.jelekin.2010.08.007.
Kelly, B.T., Kadrmas, W.R., Kirkendall, D.T., Speer, K.P., Optimal normalization tests for shoulder muscle activation: an electromyographic study. J. Orthopedic Res. 14 (1996), 647–653, 10.1002/jor.1100140421.
Lowery, M., Stoykov, N., Taflove, A., Kuiken, T., 2001. A multi-layer finite element model of the surface EMG signal 2, 1051–1054 vol. 2. http://dx.doi.org/10.1109/IEMBS.2001.1020369.
Mathiassen, S.E., Winkel, J., Hägg, G.M., Normalization of surface EMG amplitude from the upper trapezius muscle in ergonomic studies—a review. J. Electromyogr. Kinesiol. 5 (1995), 197–226.
Merletti, A.R., Torino, P., Standards for reporting EMG data. J. Electromyogr. Kinesiol. 25 (2015), I–II, 10.1016/S1050-6411(15)00221-7.
Park, S. yeon, Yoo, W. gyu, Comparison of exercises inducing maximum voluntary isometric contraction for the latissimus dorsi using surface electromyography. J. Electromyogr. Kinesiol. 23 (2013), 1106–1110, 10.1016/j.jelekin.2013.05.003.
Selkowitz, D.M., Chaney, C., Stuckey, S.J., Vlad, G., The effects of scapular taping on the surface electromyographic signal amplitude of shoulder girdle muscles during upper extremity elevation in individuals with suspected shoulder impingement syndrome. J. Orthop. Sports Phys. Ther. 37 (2007), 694–702, 10.2519/jospt.2007.2467.
Similar publications
Sorry the service is unavailable at the moment. Please try again later.
This website uses cookies to improve user experience. Read more
Save & Close
Accept all
Decline all
Show detailsHide details
Cookie declaration
About cookies
Strictly necessary
Performance
Strictly necessary cookies allow core website functionality such as user login and account management. The website cannot be used properly without strictly necessary cookies.
This cookie is used by Cookie-Script.com service to remember visitor cookie consent preferences. It is necessary for Cookie-Script.com cookie banner to work properly.
Performance cookies are used to see how visitors use the website, eg. analytics cookies. Those cookies cannot be used to directly identify a certain visitor.
Used to store the attribution information, the referrer initially used to visit the website
Cookies are small text files that are placed on your computer by websites that you visit. Websites use cookies to help users navigate efficiently and perform certain functions. Cookies that are required for the website to operate properly are allowed to be set without your permission. All other cookies need to be approved before they can be set in the browser.
You can change your consent to cookie usage at any time on our Privacy Policy page.