[en] BACKGROUND: The feasibility of recording electroencephalography (EEG) at ultra-high static magnetic fields up to 9.4 T was recently demonstrated and is expected to be incorporated into functional magnetic resonance imaging (fMRI) studies at 9.4 T. Correction of the pulse artefact (PA) is a significant challenge since its amplitude is proportional to the strength of the magnetic field in which EEG is recorded. NEW METHOD: We conducted a study in which different PA correction methods were applied to EEG data recorded inside a 9.4 T scanner in order to retrieve visual P100 and auditory P300 evoked potentials. We explored different PA reduction methods, including the optimal basis set (OBS) method as well as objective and subjective component rejection using independent component analysis (ICA). RESULTS: ICA followed by objective rejection of components is optimal for retrieving visual P100 and auditory P300 from EEG data recorded inside the scanner. COMPARISON WITH EXISTING METHODS: Previous studies suggest that OBS or OBS followed by ICA are optimal for retrieving evoked potentials at 3T. In our EEG data recorded at 9.4 T OBS performed alone was not fully optimal for the identification of evoked potentials. OBS followed by ICA was partially effective. CONCLUSIONS: In this study ICA has been shown to be an important tool for correcting the PA in EEG data recorded at 9.4 T, particularly when automated rejection of components is performed.
Arrubla, J., Neuner, I., Hahn, D., Boers, F., Shah, N.J., Recording Visual Evoked Potentials and Auditory Evoked P300 at 9.4T Static Magnetic FieldPLoS OneT static magnetic field (2013) PLOS ONE, 8 (5), pp. e62915
Bell, A.J., Sejnowski, T.J., An information-maximization approach to blind separation and blind deconvolution (1995) Neural Comput, 7 (6), pp. 1129-1159
Breuer, L., Dammers, J., Roberts, T., Shah, N.J., A Constrained ICA Approach for Real-Time Cardiac Artifact Rejection in Magnetoencephalography (2014) IEEE Trans Biomed Eng, 61 (2), pp. 405-414
Brookes, M.J., Vrba, J., Mullinger, K.J., Geirsdóttir, G.B., Yan, W.X., Stevenson, C.M., Source localisation in concurrent EEG/fMRI: applications at 7T (2009) Neuroimage, 45 (2), pp. 440-452
Cong, F., Leppanen, P.H., Astikainen, P., Hamalainen, J., Hietanen, J.K., Ristaniemi, T., Dimension reduction: additional benefit of an optimal filter for independent component analysis to extract event-related potentials (2011) J Neurosci Methods, 201 (1), pp. 269-280
Dammers, J., Schiek, M., Boers, F., Silex, C., Zvyagintsev, M., Pietrzyk, U., Integration of amplitude and phase statistics for complete artifact removal in independent components of neuromagnetic recordings (2008) IEEE Trans Biomed Eng, 55 (10), pp. 2353-2362
Dammers, J., Schiek, M., Detection of Artifacts and Brain Responses Using Instantaneous Phase Statistics in Independent Components (2011) Magnetoencephalography, pp. 131-150. , InTech, E.W. Pang (Ed.)
Debener, S., Mullinger, K.J., Niazy, R.K., Bowtell, R.W., Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7T static magnetic field strength (2008) Int J Psychophysiol, 67 (3), pp. 189-199
Debener, S., Ullsperger, M., Siegel, M., Fiehler, K., von Cramon, D.Y., Engel, A.K., Trial-by-trial coupling of concurrent electroencephalogram and functional magnetic resonance imaging identifies the dynamics of performance monitoring (2005) J Neurosci, 25 (50), pp. 11730-11737
Delorme, A., Makeig, S., EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis (2004) J Neurosci Methods, 134 (1), pp. 9-21
Huiskamp, G.J.M., Reduction of the Ballistocardiogram Artifact in Simultaneous EEG-fMRI using ICA (2005) Conf Proc IEEE Eng Med Biol Soc, 4, pp. 3691-3694
Hyvärinen, A., Fast and robust fixed-point algorithms for independent component analysis (1999) IEEE Trans Neural Netw, 10 (3), pp. 626-634
Iriarte, J., Urrestarazu, E., Valencia, M., Alegre, M., Malanda, A., Viteri, C., Independent component analysis as a tool to eliminate artifacts in EEG: a quantitative study (2003) J Clin Neurophysiol, 20 (4), pp. 249-257
Juckel, G., Karch, S., Kawohl, W., Kirsch, V., Jäger, L., Leicht, G., Age effects on the P300 potential and the corresponding fMRI BOLD-signal (2012) Neuroimage, 60 (4), pp. 2027-2034
Jung, T.P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., Sejnowski, T.J., Removal of eye activity artifacts from visual event-related potentials in normal and clinical subjects (2000) Clin Neurophysiol, 111 (10), pp. 1745-1758
Kim, Y.H., Kang, H.-C., Kim, D.-S., Kim, S.H., Shim, K.-W., Kim, H.D., Neuroimaging in identifying focal cortical dysplasia and prognostic factors in pediatric and adolescent epilepsy surgery (2011) Epilepsia, 52 (4), pp. 722-727
Koike, T., Kan, S., Misaki, M., Miyauchi, S., Connectivity pattern changes in default-mode network with deep non-REM and REM sleep (2011) Neurosci Res, 69 (4), pp. 322-330
Laufs, H., A personalized history of EEG-fMRI integration (2012) Neuroimage, 62 (2), pp. 1056-1067
Lee, T.W., Girolami, M., Sejnowski, T.J., Independent component analysis using an extended infomax algorithm for mixed subgaussian and supergaussian sources (1999) Neural Comput, 11 (2), pp. 417-441
Li, Y., Ma, Z., Lu, W., Li, Y., Automatic removal of the eye blink artifact from EEG using an ICA-based template matching approach (2006) Physiol Meas, 27 (4), pp. 425-436
Makeig, S., Jung, T.P., Bell, A.J., Ghahremani, D., Sejnowski, T.J., Blind separation of auditory event-related brain responses into independent components (1997) Proc Natl Acad Sci U S A, 94 (20), pp. 10979-10984
Mantini, D., Perrucci, M.G., Cugini, S., Ferretti, A., Romani, G.L., Del Gratta, C., Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis (2007) Neuroimage, 34 (2), pp. 598-607
De Martino, F., de Borst, A.W., Valente, G., Goebel, R., Formisano, E., Predicting EEG single trial responses with simultaneous fMRI and relevance vector machine regression (2011) Neuroimage, 56 (2), pp. 826-836
Mullinger, K., Brookes, M., Stevenson, C., Morgan, P., Bowtell, R., Exploring the feasibility of simultaneous electroencephalography/functional magnetic resonance imaging at 7T (2008) Magn Reson Imaging, 26 (7), pp. 968-977
Mullinger, K.J., Havenhand, J., Bowtell, R., Identifying the sources of the pulse artefact in EEG recordings made inside an MR scanner (2013) Neuroimage, 71, pp. 75-83
Neuner, I., Arrubla, J., Felder, J., Shah, N.J., Simultaneous EEG-fMRI acquisition at low, high and ultra-high magnetic fields up to 9.4T: Perspectives and challenges (2013) Neuroimage, , pii: S1053-8119(13)00685-X
Neuner, I., Warbrick, T., Arrubla, J., Felder, J., Celik, A., Reske, M., EEG acquisition in ultra-high static magnetic fields up to 9.4T (2013) Neuroimage, 68, pp. 214-220
Neuner, I., Arrubla, J., Werner, C.J., Hitz, K., Boers, F., Kawohl, W., The default mode network and EEG regional spectral power: a simultaneous fMRI-EEG study (2014) PLOS ONE, 9 (2), pp. e88214
Niazy, R.K., Beckmann, C.F., Iannetti, G.D., Brady, J.M., Smith, S.M., Removal of FMRI environment artifacts from EEG data using optimal basis sets (2005) Neuroimage, 28 (3), pp. 720-737
Olman, C.A., Harel, N., Feinberg, D.A., He, S., Zhang, P., Ugurbil, K., Layer-specific fMRI reflects different neuronal computations at different depths in human V1 (2012) PLOS ONE, 7 (3), pp. e32536
Oostenveld, R., Praamstra, P., The five percent electrode system for high-resolution EEG and ERP measurements (2001) Clin Neurophysiol, 112 (4), pp. 713-719
Rasheed, T., Lee, Y.-K., Lee, S.Y., Kim, T.-S., Attenuation of artifacts in EEG signals measured inside an MRI scanner using constrained independent component analysis (2009) Physiol Meas, 30 (4), pp. 387-404
Shah, N.J., Oros-Peusquens, A.-M., Arrubla, J., Zhang, K., Warbrick, T., Mauler, J., Advances in multimodal neuroimaging: hybrid MR-PET and MR-PET-EEG at 3T and 9.4T (2013) J Magn Reson, 229, pp. 101-115
Srivastava, G., Crottaz-Herbette, S., Lau, K.M., Glover, G.H., Menon, V., ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner (2005) J Neuroimage, 24 (1), pp. 50-60
Vanderperren, K., De Vos, M., Ramautar, J.R., Novitskiy, N., Mennes, M., Assecondi, S., Removal of BCG artifacts from EEG recordings inside the MR scanner: a comparison of methodological and validation-related aspects (2010) Neuroimage, 50 (3), pp. 920-934
Yacoub, E., Van De Moortele, P.-F., Shmuel, A., Uǧurbil, K., Signal and noise characteristics of Hahn SE and GE BOLD fMRI at 7T in humans (2005) Neuroimage, 24 (3), pp. 738-750