Paper published in a book (Scientific congresses and symposiums)
Conversion of visual post fire measurements into fire severity with the aid of thermo-plastic analysis for retrofitting
Molkens, Tom; Gernay, Thomas; Van Coile, Ruben
2016In Garlock, Maria; Kodur, Venkatesh (Eds.) Structures in Fire (Proceedings of the Ninth International Conference)
Peer reviewed
 

Files


Full Text
SiF16_paper_0302_preprint.pdf
Author preprint (448.88 kB)
copyright (c) 2016 DEStech Publications, Inc
Download
Full Text Parts
SiF2016-Molkens_Gernay-postprint.pdf
Publisher postprint (761.51 kB)
Request a copy
Annexes
PN_180_Conversion of visual post fire measurements into fire.pdf
Publisher postprint (1.2 MB)
Presentation in pdf
Request a copy
PN_180_Conversion of visual post fire measurements into fire.pptx
Publisher postprint (3.64 MB)
Presentation in ppt
Request a copy

Copyright © 2016 by DEStech Publications, Inc.


All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Concrete building; Post Fire; Reliability assessment; Numerical simulation; Residual capacity
Abstract :
[en] At Koksijde in Belgium a severe fire took place in an apartment building in 2015, resulting in the death of a young man and visible structural damage to four balconies. Following the fire, experts were mandated to assess the damage and the need for structural repair. They estimated that the balconies had to be refurbished but that there were no other structural elements affected, in particular the slab inside the apartment could be left in place with only a surface treatment and new plaster finishing. However, the floor slab in the apartment located above the fire apartment exhibited several visual indications that the fire could have had a structural impact, such as residual deformations and cracks in the tiles. This paper presents a methodology to infer the fire severity based on post-fire measurements and non-linear thermo-plastic numerical simulations. Finally, knowing the fire severity, its effect on the structure is evaluated and a reliability-based assessment is made of the residual load bearing capacity of the slab.
Disciplines :
Civil engineering
Author, co-author :
Molkens, Tom;  StuBeCo bvba
Gernay, Thomas ;  Université de Liège > Département ArGEnCo > Ingénierie du feu
Van Coile, Ruben;  Ghent University > Department of Structural Engineering
Language :
English
Title :
Conversion of visual post fire measurements into fire severity with the aid of thermo-plastic analysis for retrofitting
Publication date :
10 June 2016
Event name :
9th International Conference on Structures in Fire (SiF 2016)
Event organizer :
Princeton University
Event place :
Princeton, United States
Event date :
8-10 June 2016
Audience :
International
Main work title :
Structures in Fire (Proceedings of the Ninth International Conference)
Author, co-author :
Garlock, Maria
Kodur, Venkatesh
Publisher :
DEStech Publications, Inc., Lancaster, PA, United States
ISBN/EAN :
978-1-60595-320-5
Pages :
893-900
Peer reviewed :
Peer reviewed
Available on ORBi :
since 21 March 2016

Statistics


Number of views
66 (8 by ULiège)
Number of downloads
50 (2 by ULiège)

Bibliography


Similar publications