Article (Scientific journals)
Measurement of selected polybrominated diphenyl ethers, polybrominated and polychlorinated biphenyls, and organochlorine pesticides in human serum and milk using comprehensive two-dimensional gas chromatography isotope dilution time-of-flight mass spectrometry
Focant, Jean-François; Sjodin, Andreas; Turner, Wayman E. et al.
2004In Analytical Chemistry, 76 (21), p. 6313-6320
Peer Reviewed verified by ORBi
 

Files


Full Text
10.1021ac048959i.pdf
Publisher postprint (316.17 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
GCxGC; PCBs; Organochlorine pesticide; PBDEs
Abstract :
[en] A new method using comprehensive two-dimensional gas chromatography and isotope dilution time-of-flight mass spectrometry (GC x GC-IDTOFMS) for the simultaneous measurement of selected polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), and brominated flame retardants is presented. In contrast to the reference methods based on classical GC/MS, a single injection of the extract containing all compounds of interest results in accurate identification and quantification. Using GC x GC ensures the chromatographic separation of most compounds, and TOFMS allows mass spectral deconvolution of coeluting compounds as well as the use of C-13-labeled internal standards for quantification. Isotope ratio measurements of the most intense ions for both native and labels ensure the required specificity. The use of this new method with an automated sample preparation procedure developed at the Centers for Disease Control and Prevention (CDC) for the analysis of human serum and milk compared favorably to conventional isotope-dilution one-dimensional gas chromatography-high-resolution mass spectrometty (GC-IDHRMS) for the different human serum and milk pools tested. The instrumental detection limits ranged between 0.5 pg/muL and 10 pg/muL and the method detection limits ranged between I and 15 pg/muL (N = 59 analytes). The reproducibility of the method was almost as good as with GC-IDHRMS, the relative standard deviations ranging between 1 and 11% for OCPs measured in human serum. OCP, PBDE, and PCB levels measured using the two methods were highly correlated, and the deviations between the two methods were below 20% for most analytes with concentrations above 1 ng/g milk lipids.
Disciplines :
Chemistry
Author, co-author :
Focant, Jean-François  ;  Centers for Disease Control and Prevention - CDC > OAT Lab
Sjodin, Andreas
Turner, Wayman E.
Patterson, Donald G.
Language :
English
Title :
Measurement of selected polybrominated diphenyl ethers, polybrominated and polychlorinated biphenyls, and organochlorine pesticides in human serum and milk using comprehensive two-dimensional gas chromatography isotope dilution time-of-flight mass spectrometry
Publication date :
01 November 2004
Journal title :
Analytical Chemistry
ISSN :
0003-2700
eISSN :
1520-6882
Publisher :
Amer Chemical Soc, Washington, United States - Washington
Volume :
76
Issue :
21
Pages :
6313-6320
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 09 July 2009

Statistics


Number of views
209 (7 by ULiège)
Number of downloads
2 (2 by ULiège)

Scopus citations®
 
115
Scopus citations®
without self-citations
100
OpenCitations
 
110

Bibliography


Similar publications



Contact ORBi