[en] This paper presents the results of an experimental campaign performed to assess the effect of the flame emissivity for steel members engulfed into fire. In detail, two sizes of circular steel tubes were engulfed into pool fires of two different diameters. Two fuels were used and for both fuels tests without column (used as comparison with existing localised fire models) and with column were performed. The temperature of the column and of the flames were measured at different heights. The width of the flame was also measured and used to calculate the emissivity of the flame the value of which was employed in numerical simulations in order to predict the evolution of the temperature of the steel column. Comparison with numerical analyses where the recommended values of the Eurocode were used is also shown.
Disciplines :
Civil engineering
Author, co-author :
Tondini, Nicola; Univ. of Trento
Vassart, Olivier; ArcelorMittal
Franssen, Jean-Marc ; Université de Liège - ULiège > Département ArGEnCo > Ingénierie du feu
Language :
English
Title :
Experimental assessment of the effect of the real flame emissivity for steel elements engulfed into fire
Publication date :
2013
Event name :
Fire and Material Conference
Event organizer :
Interscience Communications
Event place :
San Francisco, United States
Event date :
Janvier 2013
Audience :
International
Main work title :
Proceedings of the Fire and Materials 2013 Conference
Editor :
Babrauska, Vytenis
Grayson, Stephen
Hirschler, Marcelo
Janssens, Marc
Van Hees, Patrick
Publisher :
Interscience Communications Ltd, London, United Kingdom
Pages :
175-186
Peer reviewed :
Peer reviewed
Funders :
ArcelorMittal Research
Funding text :
The financial support of ArcelorMittal and of the Province of Trento through the Call 3 - post-doc 2009 (Outgoing) - FIRAS project are gratefully acknowledged.
Pchelintsev, A., Hasemi, Y., Wakamatsu, T. and Yokobayashi, Y. 1997, Experimental and numerical study on the behaviour of a steel beam under ceiling exposed to a localized fire, Fire Safety Science 5: 1153-1164. doi:10.3801/IAFSS.FSS.5-1153
Heskestad, G. 1984, Engineering Relations for Fire Plumes, Fire Safety Journal, 7: 25-32.
EN 1991-1-2 2002, Eurocode 1: Actions on structures - Part 1-2: General actions - Actions on structures exposed to fire, CEN, Bruxelles
Franssen, J.M. 2005, SAFIR. A Thermal/Structural Program Modelling Structures under Fire, Engineering Journal, A.I.S.C.;42(3), 143-158
Byström, A., Sjöström J., Wickström U. and Veljkovic M. 2012, Large scale test to explore thermal exposure of column exposed to localized fire, in Proceedings of the 7th International Conference on Structures in Fire, Zurich, Switzerland, 6-8 June
EN1993-1-2 2005, Eurocode 3: Design of steel structures - Part 1-2: General rules -Structural fire design, CEN, Bruxelles