Evaluation of automated immunoassays for 25 (OH)-vitamin D determination in different critical populations before and after standardization of the assays
CAVALIER, Etienne ; Centre Hospitalier Universitaire de Liège - CHU > Service de Chimie Clinique
LUKAS, Pierre ; Centre Hospitalier Universitaire de Liège - CHU > Service de Chimie Clinique
CRINE, Yannick ; Centre Hospitalier Universitaire de Liège - CHU > Service de Chimie Clinique
PEETERS, Stéphanie ; Centre Hospitalier Universitaire de Liège - CHU > Service de Chimie Clinique
CARLISI, Ignazia ; Centre Hospitalier Universitaire de Liège - CHU > Service de Chimie Clinique
LE GOFF, Caroline ; Centre Hospitalier Universitaire de Liège - CHU > Service de Chimie Clinique
GADISSEUR, Romy ; Centre Hospitalier Universitaire de Liège - CHU > Service de Chimie Clinique
DELANAYE, Pierre ; Centre Hospitalier Universitaire de Liège - CHU > Néphrologie
Souberbielle, Jean-Claude
Language :
English
Title :
Evaluation of automated immunoassays for 25 (OH)-vitamin D determination in different critical populations before and after standardization of the assays
Wallace A.M., Gibson S., de la HA, Lamberg-Allardt C., Ashwell M. Measurement of 25-hydroxyvitamin D in the clinical laboratory: current procedures, performance characteristics and limitations. Steroids 2010, 75:477-488.
Powe C.E., Evans M.K., Wenger J., et al. Vitamin D-binding protein and vitamin D status of black Americans and white Americans. N Engl J Med 2013, 369:1991-2000.
Heijboer A.C., Blankenstein M.A., Kema I.P., Buijs M.M. Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration. Clin Chem 2012, 58:543-548.
Depreter B., Heijboer A.C., Langlois M.R. Accuracy of three automated 25-hydroxyvitamin D assays in hemodialysis patients. Clin Chim Acta 2013, 415:255-260.
Cavalier E., Wallace A.M., Carlisi A., Chapelle J.P., Delanaye P., Souberbielle J.C. Cross-reactivity of 25-hydroxy vitamin D2 from different commercial immunoassays for 25-hydroxy vitamin D: an evaluation without spiked samples. Clin Chem Lab Med 2011, 49:555-558.
Kobold U. Approaches to measurement of vitamin D concentrations - mass spectrometry. Scand J Clin Lab Invest Suppl 2012, 243:54-59.
Cavalier E., Carlisi A., Bekaert A.C., Rousselle O., Chapelle J.P. Human anti-animal interference in DiaSorin Liaison total 25(OH)-vitamin D assay: towards the end of a strange story?. Clin Chim Acta 2012, 413:527-528.
Sempos C.T., Vesper H.W., Phinney K.W., Thienpont L.M., Coates P.M. Vitamin D status as an international issue: national surveys and the problem of standardization. Scand J Clin Lab Invest Suppl 2012, 243:32-40.
Stepman H.C., Vanderroost A., Van U.K., Thienpont L.M. Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry. Clin Chem 2011, 57:441-448.
Herrmann M. The measurement of 25-hydroxy vitamin D - an analytical challenge. Clin Chem Lab Med 2012, 50:1873-1875.