[en] OBJECTIVES: The residual stress profile developed within the veneering ceramic during the manufacturing process is an important predicting factor in chipping failures, which constitute a well-known problem with yttria-tetragonal-zirconia polycrystal (Y-TZP) based restorations. The objectives of this study are to measure and to compare the residual stress profile in the veneering ceramic layered on three different polycrystalline ceramic framework materials: Y-TZP, alumina polycrystal (AL) and zirconia toughened alumina (ZTA). METHODS: The stress profile was measured with the hole-drilling method in bilayered disk samples of 19mm diameter with a 0.7mm thick Y-TZP, AL or ZTA framework and a 1.5mm thick layer of the corresponding veneering ceramic. RESULTS: The AL samples exhibited increasing compressive stresses with depth, while compressive stresses switching into interior tensile stresses were measured in Y-TZP samples. ZTA samples exhibited compressive stress at the ceramic surface, decreasing with depth up to 0.6mm from the surface, and then becoming compressive again near the framework. SIGNIFICANCE: Y-TZP samples exhibited a less favorable stress profile than those of AL and ZTA samples. Results support the hypothesis of the occurrence of structural changes within the Y-TZP surface in contact with the veneering ceramic to explain the presence of tensile stresses. Even if the presence of Y-TZP in the alumina matrix seems to negatively affect the residual stress profiles in ZTA samples in comparison with AL samples, the registered profiles remain positive in terms of veneer fracture resistance.
Research Center/Unit :
d‐BRU - Dental Biomaterials Research Unit - ULiège [BE]
Disciplines :
Materials science & engineering Dentistry & oral medicine
Author, co-author :
Fukushima, K. A.
Sadoun, M. J.
Cesar, P. F.
MAINJOT, Amélie ; Centre Hospitalier Universitaire de Liège - CHU > Institut de dentisterie - prothèse fixée
Language :
English
Title :
Residual stress profiles in veneering ceramic on Y-TZP, alumina and ZTA frameworks: Measurement by hole-drilling
Publication date :
February 2014
Journal title :
Dental Materials
ISSN :
0109-5641
eISSN :
1879-0097
Publisher :
Elsevier, Netherlands
Volume :
30
Issue :
2
Pages :
105-111
Peer reviewed :
Peer Reviewed verified by ORBi
Commentary :
Copyright (c) 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
A.H. De Aza, J. Chevalier, G. Fantozzi, M. Schehl, and R. Torrecillas Crack growth resistance of alumina, zirconia and zirconia toughened alumina ceramics for joint prostheses Biomaterials 23 February (3) 2002 937 945 [Research Support, Non-U.S. Gov't]. (Pubitemid 33108971)
D.X. Tang, H.B. Lim, K.J. Lee, C.H. Lee, and W.S. Cho Evaluation of mechanical reliability of zirconia-toughened alumina composites for dental implants Ceram Int 38 April (3) 2012 2429 2436
N.U. Zitzmann, M.L. Galindo, E. Hagmann, and C.P. Marinello Clinical evaluation of Procera AllCeram crowns in the anterior and posterior regions Int J Prosthodont 20 May-June (3) 2007 239 241 [evaluation studies]
A.S. Kassem, O. Atta, and O. El-Mowafy Survival rates of porcelain molar crowns - an update Int J Prosthodont 23 January-February (1) 2010 60 62
R. Sorrentino, L. Galasso, S. Tete, G. De Simone, and F. Zarone Clinical evaluation of 209 all-ceramic single crowns cemented on natural and implant-supported abutments with different luting agents: a 6-year retrospective study Clin Implant Dent Relat Res 14 April (2) 2012 184 197
B. Al-Amleh, K. Lyons, and M. Swain Clinical trials in zirconia: a systematic review J Oral Rehabil 37 August-September-October (8) 2010 641 652
I. Sailer, A. Feher, F. Filser, L.J. Gauckler, H. Luthy, and C.H. Hammerle Five-year clinical results of zirconia frameworks for posterior fixed partial dentures Int J Prosthodont 20 July-August (4) 2007 383 388
J.S. Schley, N. Heussen, S. Reich, J. Fischer, K. Haselhuhn, and S. Wolfart Survival probability of zirconia-based fixed dental prostheses up to 5 yr: a systematic review of the literature Eur J Oral Sci 118 October (5) 2010 443 450
S.D. Heintze, and V. Rousson Survival of zirconia- and metal-supported fixed dental prostheses: a systematic review Int J Prosthodont 23 November-December (6) 2010 493 502
J. Pelaez, P.G. Cogolludo, B. Serrano, J.F. Serrano, and M.J. Suarez A four-year prospective clinical evaluation of zirconia and metal-ceramic posterior fixed dental prostheses Int J Prosthodont 25 September-October (5) 2012 451 458
P. Vigolo, and S. Mutinelli Evaluation of zirconium-oxide-based ceramic single-unit posterior fixed dental prostheses (FDPs) generated with two CAD/CAM systems compared to porcelain-fused-to-metal single-unit posterior FDPs: a 5-year clinical prospective study J Prosthodont 21 June (4) 2012 265 269
V. Lughi, and V. Sergo Low temperature degradation - aging - of zirconia: a critical review of the relevant aspects in dentistry Dent Mater 26 August (8) 2010 807 820
J. Chevalier, S. Grandjean, M. Kuntz, and G. Pezzotti On the kinetics and impact of tetragonal to monoclinic transformation in an alumina/zirconia composite for arthroplasty applications Biomaterials 30 October (29) 2009 5279 5282
D. Gutknecht, J. Chevalier, V. Garnier, and G. Fantozzi Key role of processing to avoid low temperature ageing in alumina zirconia composites for orthopaedic application J Eur Ceram Soc 27 2-3 2007 1547 1552 (Pubitemid 44743194)
G. Gostemeyer, M. Jendras, M.P. Dittmer, F.W. Bach, M. Stiesch, and P. Kohorst Influence of cooling rate on zirconia/veneer interfacial adhesion Acta Biomater 6 December (12) 2010 4532 4538
A.K. Mainjot, G.S. Schajer, A.J. Vanheusden, and M.J. Sadoun Influence of cooling rate on residual stress profile in veneering ceramic: measurement by hole-drilling Dent Mater 27 September (9) 2011 906 914
E.D. Rekow, N.R. Silva, P.G. Coelho, Y. Zhang, P. Guess, and V.P. Thompson Performance of dental ceramics: challenges for improvements J Dent Res 90 August (8) 2011 937 952
A.K. Mainjot, G.S. Schajer, A.J. Vanheusden, and M.J. Sadoun Influence of zirconia framework thickness on residual stress profile in veneering ceramic: measurement by hole-drilling Dent Mater 28 April (4) 2012 378 384
A.K. Mainjot, G.S. Schajer, A.J. Vanheusden, and M.J. Sadoun Influence of veneer thickness on residual stress profile in veneering ceramic: measurement by hole-drilling Dent Mater 28 February (2) 2012 160 167
A.K. Mainjot, T. Douillard, L. Gremillard, M.J. Sadoun, and J. Chevalier 3D-characterization of the veneer-zirconia interface using FIB nano-tomography Dent Mater 29 February (2) 2013 157 165
E.A. Bonfante, B.T. Rafferty, N.R. Silva, J.C. Hanan, E.D. Rekow, and V.P. Thompson et al. Residual thermal stress simulation in three-dimensional molar crown systems: a finite element analysis J Prosthodont 21 October (7) 2012 529 534
N. De Jager, M. de Kler, and J.M. van der Zel The influence of different core material on the FEA-determined stress distribution in dental crowns Dent Mater 22 March (3) 2006 234 242 (Pubitemid 43199612)
M.V. Swain Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures Acta Biomater 5 June (5) 2009 77 1668
A.K. Mainjot, G.S. Schajer, A.J. Vanheusden, and M.J. Sadoun Residual stress measurement in veneering ceramic by hole-drilling Dent Mater 27 May (5) 2011 439 444
M.J. Tholey, M.V. Swain, and N. Thiel Thermal gradients and residual stresses in veneered Y-TZP frameworks Dent Mater 27 November (11) 2011 10 1102 [comparative study]
J.C. Durand, B. Jacquot, H. Salehi, M. Fages, J. Margerit, and F.J. Cuisinier Confocal Raman microscopic analysis of the zirconia/feldspathic ceramic interface Dent Mater 28 June (6) 2012 661 671