Reference : Dynamic simulations of solar combisystems integrating a seasonal sorption storage: In...
Scientific congresses and symposiums : Paper published in a journal
Engineering, computing & technology : Energy
http://hdl.handle.net/2268/153348
Dynamic simulations of solar combisystems integrating a seasonal sorption storage: Influence of the combisystem configuration
English
Hennaut, Samuel mailto [Université de Liège - ULiège > DER Sc. et gest. de l'environnement (Arlon Campus Environ.) > Monitoring et simulation énergétique des bâtiments >]
Thomas, Sébastien [Université de Liège - ULiège > DER Sc. et gest. de l'environnement (Arlon Campus Environ.) > Surveillance de l'environnement >]
Davin, Elisabeth mailto [Université de Liège - ULiège > DER Sc. et gest. de l'environnement (Arlon Campus Environ.) > DER Sc. et gest. de l'environnement (Arlon Campus Environ.) >]
Skrylnyk, Alexandre mailto [Université de Mons - UMONS > Pôle Energie > Thermodynamique > >]
Frère, Marc mailto [Université de Mons - UMONS > Pôle Energie > Thermodynamique > >]
Dec-2012
Strojarstvo
Croatian Union of Mechanical Engineers and Naval Architects
54
6
433-440
Yes
No
National
0562-1887
Zagreb
Croatia
EuroSun 2012 ISES-Europe Solar Conference
du 18 septembre 2012 au 20 septembre 2012
ISES-Europe and Croatian Solar Energy Association Rijeka
Rijeka
Croatia
[en] seasonal storage ; solar combisystem ; bromide strontium ; adsorption
[en] This paper focuses on the sizing of solar combisystems with adsorption seasonal storage to target autonomous solar space heating. Two main configurations of the combisystem are simulated, including one or two tanks. The influence of the seasonal storage on the sizing of the tanks is also discussed. Results show that performances of the system with two tanks are better (2 to 4 % with seasonal storage) but some improvements should be possible for the single tank configuration. The sizing of the sensible storage is nearly independent of the solar collectors area if there is a seasonal storage. The sensible storage size increase with the collectors area without adsorption storage. The analysis is conducted in simulation using the TRNSYS program.
Plan Marshall - Région Wallonne
SOLAUTARK
Researchers ; Professionals ; Students
http://hdl.handle.net/2268/153348

File(s) associated to this reference

Fulltext file(s):

FileCommentaryVersionSizeAccess
Open access
Paper_strojarstvo.pdfAuthor preprint623.5 kBView/Open

Additional material(s):

File Commentary Size Access
Open access
poster_Eurosun.pdf932.47 kBView/Open

Bookmark and Share SFX Query

All documents in ORBi are protected by a user license.