Paper published in a journal (Scientific congresses and symposiums)
Determination of urinary metanephrine, normetanephrine and methoxymetanephrine by liquid chromatography-electrospray tandem mass spectrometry.
LE GOFF, Caroline; PEETERS, Stéphanie; NETCHACOVITCH, Matthieu et al.
2013In Biochimica Clinica, 37 (SS), p. 316
Peer reviewed
 

Files


Full Text
Poster_euromedlab 2013 metanephrines 2.pdf
Author postprint (334.53 kB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] Background: The aim of this work was to develop and validate a method for the determination of metanephrine (M), normetanephrine (NM) and methoxymetanephrine (METHO) in urine by liquid chromatography-tandem mass spectrometry (LCMS-MS) on the Triple Quad TQ 5500 from AB SCIEX. In fact, the determination of M and NM concentrations is used in clinical diagnosis of pheochromocytoma, a rare but potentially fatal tumor arising primarily from the chromaffin cells of the adrenal medulla. Methods: The samples were made of 24 hours acidified urines after centrifugation. Sample preparation was performed by hydrolysing and purifying by extraction column. After that, labeled M, NM and METHO were added as internal standard. Samples were analysed by liquid chromatography-electrospray tandem mass spectrometry. We determined the repeatability, reproducibility, accuracy profile and recovery on pooling urines samples from 9 volunteers analysed in triple run. Results: The results of the precision evaluation are shown in table. The repeatability did not exceed 8.4 % for M, 6.8% for NM and 10.8% for METHO. The concentration range was 71-781 µg/24h, 71-853 µg/24h and 20-854µg/24h for the M, NM and METHO respectively. The total precision did not exceed 12.5%, 11.8% and 8.8% for M, NM and METHO. The limit of quantification (LOQ) were 33.77µg/24h, 14.49µg/24H and 19.81 µg/24H for M, NM and METHO respectively. The accuracy varied from 99.69 to 100.2% for a range of 71 to 781 µg/24h, from 93.32 to 100.2% for a range of 71-853 µg/24h and from 99.85 to 100.6% for the range 20-854µg/24h for M, NM and METHO respectively. The recovery were 99.96% (95% CI for the mean: 96.5-103.4), 99.75% (96.5-102.9) and 100.08 (95.97-104.2) for the M, NM and METHO respectively. Conclusions: We have successfully developed and validated an LCMS-MS method to determine urinary M, NM and METHO on the TQ 5500 from AB SCIEX. It represents a convincing alternative to the HPLC method for a faster and reliable measurement of urinary M, NM and METHO.
Disciplines :
Laboratory medicine & medical technology
Author, co-author :
LE GOFF, Caroline  ;  Centre Hospitalier Universitaire de Liège - CHU > Chimie médicale
PEETERS, Stéphanie ;  Centre Hospitalier Universitaire de Liège - CHU > Chimie médicale
NETCHACOVITCH, Matthieu ;  Centre Hospitalier Universitaire de Liège - CHU > Chimie médicale
Kaux, Jean-François  ;  Université de Liège - ULiège > Département des sciences de la motricité > Département des sciences de la motricité
CRINE, Yannick ;  Centre Hospitalier Universitaire de Liège - CHU > Chimie médicale
Cavalier, Etienne  ;  Université de Liège - ULiège > Département de pharmacie > Chimie médicale
Language :
English
Title :
Determination of urinary metanephrine, normetanephrine and methoxymetanephrine by liquid chromatography-electrospray tandem mass spectrometry.
Publication date :
May 2013
Event name :
Euromedlab 2013
Event place :
Milan, Italy
Event date :
19-23 May 2013
Audience :
International
Journal title :
Biochimica Clinica
ISSN :
0393-0564
Publisher :
CLAS International, Italy
Volume :
37
Issue :
SS
Pages :
S316
Peer reviewed :
Peer reviewed
Available on ORBi :
since 19 June 2013