Article (Scientific journals)
Analytical validation based on total error measurement and cut-off interpretation of a neonatal screening TSH-immunoassay.
Boemer, François; Bours, Vincent; Schoos, Roland et al.
2009In Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, 877, p. 2412-2417
Peer Reviewed verified by ORBi
 

Files


Full Text
ARTICLE TEL QUE PUBLIE.pdf
Author postprint (401.43 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] To prevent the severe developmental and physical morbidities associated with congenital hypothyroidism, we developed a home-made Enzyme-Linked Immunosorbent Assay (ELISA) method to quantify Thyroid Stimulating Hormone (TSH) levels on newborn dried blood spots. In order to agree with actual clinical laboratory quality referential (ISO 15189), we desired to update our analytical validation protocol. For this purpose, an approach using accuracy profiles based on tolerance intervals for the total error measurement was for first time applied to an immunological assay. According to acceptance limits fixed at +/-30%, the method was found accurate over a concentration range from 17.48 to 250mIU/L. Based on 99.5 percentile of a 16,459 newborn population, cut-off was fixed at 20.1mIU/L and validated against normal and pathologic neonatal populations. Additionally, uncertainty regions around this value were obtained applying four different approaches. Finally, we demonstrated here our in-house immunological technique fulfils criterions of a neonatal screening policy.
Disciplines :
Biochemistry, biophysics & molecular biology
Author, co-author :
Boemer, François  ;  Centre Hospitalier Universitaire de Liège - CHU > Génétique
Bours, Vincent ;  Université de Liège - ULiège > Département des sciences biomédicales et précliniques > Génétique générale et humaine
Schoos, Roland ;  Centre Hospitalier Universitaire de Liège - CHU > Génétique
Hubert, Philippe  ;  Université de Liège - ULiège > Département de pharmacie > Chimie analytique
Rozet, Eric ;  Université de Liège - ULiège > Département de pharmacie > Chimie analytique
Language :
English
Title :
Analytical validation based on total error measurement and cut-off interpretation of a neonatal screening TSH-immunoassay.
Publication date :
2009
Journal title :
Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences
ISSN :
1570-0232
eISSN :
1873-376X
Publisher :
Elsevier Science, Amsterdam, Netherlands
Volume :
877
Pages :
2412-2417
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 28 November 2008

Statistics


Number of views
164 (34 by ULiège)
Number of downloads
4 (2 by ULiège)

Scopus citations®
 
12
Scopus citations®
without self-citations
9
OpenCitations
 
11

Bibliography


Similar publications