[en] The objective of this study was to compare the repeatability of echocardiographic measurements obtained from different echocardiographic modes and views in healthy adult equids of various sizes, breeds and thorax shapes.
Ten, free of cardiac disease, equids (body weight: 120 to 662 kg; age: 1 to 26 years) from various breeds were used in this study. Each animal was submitted to a standardized echocardiographic and Doppler protocol 3 times at 1 day interval. This protocol included the measurements of left and right ventricular, aortic, pulmonary, and left atrial parameters obtained from different views using the bidimensional (2D) or the motion (M) modes, and the measurement of several parameters of blood flow obtained from the pulsed wave Doppler mode. Repeatability of each measurement was estimated on the basis of the residual variance using a linear model and the coefficient of variation of repeated measurements. A two by two comparison of the repeatability of measurements performed in different views was performed using the residual variances in a variance ratio F test.
Results showed that repeatability of echocardiographic or Doppler measurements in equids of various sizes, breeds and thorax shapes are comparable to previously reported results in thoroughbred and standardbred horses. Left ventricular morphologic parameters showed a good repeatability in the classic M-mode right parasternal short axis (Sax) view at the level of the chordae tendinae, but the 2D-mode right parasternal long axis (LAx) four- chambers view appeared to offer an interesting alternative to measure them. This latter view also allowed obtaining the mostre repeatable measurement of right ventricular internal diameter. The left atrial diameter was maximal and most repeatable in the 2D-mode left parasternal long axisLAx four- chambers angled view, and the repeatability of the aortic diameter was best in the 2D-mode right parasternal long axisLAx five-chambers view. Finally, aortic systolic time intervals were more repeatable when measured from the Doppler mode as compared to the M-mode.
ThusIn conclusion, best repeatability of echocardiographic measurements in horses could be optimized following an echocardiographicthe following protocol in equids:
1-M-mode right parasternal short axis view at the level of chordae tendinae, to measure left ventricular morphologic parameters, and 2D-mode right parasternal long axis four-chamber as an alternative view.
2-2D-mode right parasternal long axis five-chambersre, to measure the aortic diameter.
3-2D-mode left parasternal long axis four-chambersre angled view, to measure the left atrial diameter.
Disciplines :
Veterinary medicine & animal health
Author, co-author :
Al Haidar, Ali
Farnir, Frédéric ; Université de Liège - ULiège > Département de productions animales > Biostatistiques et bioinformatique appliquées aux sc. vétér.
Deleuze, Stefan ; Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Obstét. et path. de la reprod. des anim. de comp. et équidés
Sandersen, Charlotte ; Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Département clinique des animaux de compagnie et des équidés
Amory, Hélène ; Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Médecine interne des équidés
Language :
English
Title :
Comparison of the Repeatability of Echocardiographic Measurements from Different Modes and Views in Horses of Various Breeds and Sizes
June A., and Boon M.S. Physics of ultrasound. In: June A., and Boon M.S. (Eds). Manual of veterinary echocardiography (1998), Williams & Wilkins, Baltimore, MD 1-34
Pipers F.S., and Hamlin R.L. Echocardiography in horses. J Vet Med 190 (1977) 815-819
Marr C.M. Equine echocardiography-sound advice at the heart of the matter. Br Vet J 150 (1994) 537-545
Patteson M.W., Gibbs C., Wotton P.R., and Cripps P.J. Echocardiographic measurements of cardiac dimensions and indices of cardiac function in normal adult thoroughbred horses. Equine Vet J Suppl 19 (1995) 18-27
Reef V.B. Evaluation of ventricular septal defects in horses using two-dimensional and Doppler echocardiography. Equine Vet J Suppl 19 (1995) 86-96
Buhl R., Ersboll A.K., Eriksen L., and Koch J. Sources and magnitude of variation of echocardiographic measurements in normal standardbred horses. Vet Radiol Ultrasound 45 (2004) 505-512
Young L.E. Cardiac responses to training in 2-year-old thoroughbreds: an echocardiographic study. Equine Vet J Suppl 30 (1999) 195-198
Kriz N.G., Hodgson D.R., and Rose R.J. Changes in cardiac dimensions and indices of cardiac function during deconditioning in horses. Am J Vet Res 61 (2000) 1553-1560
Buhl R., Ersboll A.K., Eriksen L., and Koch J. Changes over time in echocardiographic measurements in young standardbred racehorses undergoing training and racing and association with racing performance. J Am Vet Med Assoc 226 (2005) 1881-1887
Young L.E., Blissitt K.J., Clutton R.E., Molony V., and Darke P.G. Feasibility of transoesophageal echocardiography for evaluation of left ventricular performance in anaesthetised horses. Equine Vet J Suppl 19 (1995) 63-70
Gehlen H., Kroker K., Deegen E., and Stadler P. Influence of detomidine on echocardiographic function parameters and cardiac hemodynamics in horses with and without heart murmur. [in German]. Schweiz Arch Tierheilkd 146 (2004) 119-126
Buhl R., Ersboll A.K., Larsen N.H., Eriksen L., and Koch J. The effects of detomidine or acepromazine on echocardiographic measurements and function in normal horses. Vet Anaesth Analg 34 (2007) 1-8
Menzies-Gow N.J. Effects of sedation with acepromazine on echocardiographic measurements in eight healthy thoroughbred horses. Vet Rec 163 (2008) 21-25
Voros K., Holmes J.R., and Gibbs C. Measurement of cardiac dimensions with two-dimensional echocardiography in the living horse. Equine Vet J 23 (1991) 461-465
Young L.E., and Scott G.R. Measurement of cardiac function by transthoracic echocardiography: day to day variabilty and repeatability in normal thoroughbred horses. Equine Vet J 30 (1998) 117-122
Schwarzwald C.C., Schober K.E., and Bonagura J.D. Methods and reliability of echocardiographic assessment of left atrial size and mechanical function in horses. Am J Vet Res 68 (2007) 735-747
Staddon G.E., Weaver B.M., and Webb A.I. Distribution of cardiac output in anaesthetised horses. Res Vet Sci 27 (1979) 28-45
O'callaghan M.W. Comparison of echocardiographic and autopsy measurements of cardiac dimensions in the horse. Equine Vet J 17 (1985) 361-368
Lescure F., and Tamzali Y. Reference values in M-mode echocardiography in the athletic horses. Rev Méd Vét 7 (1984) 405-418
Gehlen H., Marnette S., Rohn K., Kreienbrock L., and Stadler P. Precision controlled echocardiographic left ventricular function parameters by repeated measurement on three consecutive days and untrained warmblood horses. [in German]. Dtsch Tierarztl Wochenschr 112 (2005) 48-54
Long K.J., Bonagura J.D., and Darke G.G. Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse. Equine Vet J 24 (1992) 226-235
Blissitt K.J., and Bonagura J.D. Pulsed wave Doppler echocardiography in normal horses. Equine Vet J Suppl 19 (1995) 38-46
Blissitt K.J., and Bonagura J.D. Colour flow Doppler echocardiography in normal horses. Equine Vet J Suppl 19 (1995) 47-55
Kriz N.G., and Rose R.J. Repeatability of standard transthoracic echocardiographic measurements in horses. Aust Vet J 80 (2002) 362-370
Sampson S.N., Tucker R.L., and Bayly W.M. Relationship between VO2max, heart score and echocardiographic measurements obtained at rest and immediatly following maximal exercise in thoroughbred horses. Equine Vet J Suppl 30 (1999) 190-194
Amory H, Bertrand P, Delvaux V, Sandersen C. Doppler echocardiographic reference values in healthy donkeys (2004). Available at: http://www.ivis.org. Accessed June 17, 2007.
Thomas W.P., Gaber C.E., Jacobs G.J., Kaplan P.M., Lombard C.W., Moise S.N., et al. Recommendations for standards in transthoracic two-dimensional echocardiography in the dog and cat. J Vet Int Med 7 (1993) 247-252
Reef V.B. Echocardiograpic examination in the horse: the basics. Comp Cont Educ Pract 12 (1990) 1312-1319
Wyatt H.L., Haendchen R.V., Meerbaum S., and Corday E. Assessment of quantitative methods for 2-dimensional echocardiography. Am J Cardiol 52 (1983) 396-401
Feigenbaum H. Echocardiography. 4th ed. (1986), Lea & Febiger, Philadelphia, PA
Sampson S.N., Jacobson R.L., Sande R.D., Susumi C.J., Larntz K.J., Tucker R.L., et al. Reproducibility and repeatability of M-mode echocardiographic measurements collected from 25 normal horses. J Equine Vet Sci 19 (1999) 51-57