Monoterpenes; Radioello device; Thermal desorption; Air sampling; Tenax TA; Wooden construction; Monoterpènes; Dispositif Radiello; Désorption thermique; Prélèvement d'air; Construction en bois
Abstract :
[en] Monoterpenes are compounds naturally emitted by wooden materials. A preliminary study had demonstrated the occurrence of some monoterpenes in the timber frame constructions. Contrary to the active sampling, the passive sampling with Radiello® device simplifies the sampling step that is an interest in indoor environment. However, the knowledge of the sampling rate is necessary for quantification via the passive samplers Radiello®.
Radiello® sampler with Tenax TA cartridge was evaluated for the 4-h concentration measurements of nine monoterpenes (α-pinene, β-pinene, d-limonene, Δ3-carene, camphene, carvone, 1,8-cineole, linalool and p-cymene). The performance parameters of the method (calibration curve, trueness, repeatability, blank level, stability of samples) were estimated.
The sampling rates were first evaluated under the standard conditions in an exposure chamber. The influences of three environmental factors (temperature (T), relative humidity (RH) and concentration level (C)) on the sampling rates were also evaluated following a full factorial design at two factor levels (low and high). The monoterpenes concentrations in the exposure chamber were followed by an active sampling on tube Tenax TA. For both sampling devices, analyses were realized by TD-GC-MS.
The results of this study demonstrated that the Radiello® device is suitable for the measurement of 5 of 9 studied monoterpenes. The sampling rates were defined by an equation including two factors, temperature and relative humidity. Temperature is found to be the most important factor leading to variability of the all monoterpene sampling rates. An equation allowing to estimate the sampling rate was established for every studied compound.
Measurements of monoterpenes with the Radiello® device were then carried out on new wooden houses and compared with measurements obtained by active sampling on Tenax TA tubes.
Disciplines :
Chemistry Environmental sciences & ecology
Author, co-author :
Marlet, Christelle ; Université de Liège - ULiège > Chimie et bio-industries > Chimie analytique
Lognay, Georges ; Université de Liège - ULiège > Chimie et bio-industries > Chimie analytique
Plaisance, Hervé; Ecole des Mines Douai > Département Chimie et Environnement
Brostaux, Yves ; Université de Liège - ULiège > Sciences agronomiques > Statistique, Inform. et Mathém. appliquée à la bioingénierie
Language :
French
Title :
Evaluation d’une méthode d’échantillonnage passif pour la mesure des monoterpènes dans l’air intérieur
Alternative titles :
[en] Evaluation of a passive sampling method for the measurement of monoterpenes in indoor air
Cocheo V, Sacco P, Boaretto C et al. Urban benzene and population exposure. Nature 2000; 404: 141-2. (Pubitemid 30154470)
Crump DR, Bland BH, Mann HS et al. Personal exposure to air pollutants in Hertfordshire, England. Indoor Air'99. 1999.
Hollender J, Sandner F, Möller M, Dott W. Sensitive indoor air monitoring of monoterpenes using different adsorbents and thermal desorption gas chromatography with mass-selective detection. J. Chromato. A. 2002; 962: 175-81. (Pubitemid 34655752)
Meesters RJ, Duisken M, Jähnigen H, Hollender J. Sensitive determination of monoterpene alcohols in urine by HPLC-FLD combined with ESI-MS detection after online-solid phase extraction of the monoterpene- coumarincarbamate derivatives. J. Chromato. B. 2008; 875 : 444-50.
Brown SK, Sim MR, Abramson MJ, Gray CN. Concentrations of volatile organic compounds in indoor air a review. Indoor Air. 1994; 4: 123-34.
Weschler CJ. Changes in indoor pollutants since 1950s. Atmos. Environ. 2009; 43: 153-69.
Aoki T, Tanabe SI. Generation of sub-micron particles and secondary pollutants from building materials by ozone reaction. Atmos. Environ. 2007; 41: 3139-50. (Pubitemid 46518218)
Hodgson AT, Beal D, Mcllvaine JER. Sources of formaldehyde, other aldehydes and terpenes in a new manufactured house. Indoor Air. 2002; 12: 235-42. (Pubitemid 135747823)
Baumann MGD, Batterman SA, Zhang GH. Terpene emissions from particleboard and medium-density fiberboard products. Forest Prod. J. 1999; 49: 49-56. (Pubitemid 129693490)
Omrani P, Masson E, Pizzi A, Mansouri HR. Emission of gases and degradation volatiles from polymeric wood constituents in friction welding of woods dowels. Polymer Degradation and Stability. 2008; 93: 794-9.
Meesters RJ, Duisken M, Hollender J. Study on the cytochrome P450-mediated oxidative metabolism of the terpene alcohol linalool: indication of biological epoxidation. Xenobiotica. 2007; 37: 604-17. (Pubitemid 47037156)
Hedenstierna G, Alexandersson R, Wimander K, Rosen G. Exposures to terpenes: Effects on pulmonary function. Int. Arch. Occup. Environ. Health. 1983; 51: 191-8. (Pubitemid 13110860)
Falk AA, Hagberg MT, Lof AE et al. Uptake, distribution and elimination of α-pinene in man after exposure by inhalation. Scand. J. Work Environ. Health. 1990; 16 : 372.
Falk A, Lof A, Hagberg M, Hjelm EW, Wang Z. Human exposure to 3-carene by inhalation: toxicokinetics, effects on pulmonary function and occurrence of irritative and CNS symptoms. Toxicol. Appl. Pharmacol. 1991; 110: 198-205.
Falk-Filipsson A, Lof A, Hagberg M et al. d-Limonene exposure to humans by inhalation: Uptake, distribution, elimination and effects on the pulmonary function. J. Toxicol. Environ. Health. 1993; 38: 77-88. (Pubitemid 23045953)
Johard U, Larsson K, Lof A, Eklund A. Controlled short-time terpene exposure induces an increase of the macrophages and the mast cells in bronchoalveolar lavage fluid. Am. J. Ind. Med. 1993; 23: 793-9. (Pubitemid 23148379)
Eriksson KA, Stjernberg NL, Levin JO et al. Terpene exposure and respiratory effects among sawmill workers. Scand. J. Work Environ. Health. 1996; 22: 182-90. (Pubitemid 26242628)
Eriksson KA, Levin JO, Sandstrom T et al. Terpene exposure and respiratory effects among workers in Swedish joinery shops. Scand J. Work Environ. Health. 1997, 23: 114-20. (Pubitemid 27214008)
Kasanen JP, Pasanen AL, Pasanen P et al. Evaluation of sensory irritation of Δ 3-carene and turpentine, and acceptable levels of monoterpenes in occupational and indoor environment. J. Toxicol. Environ. Health A. 1999, 57: 89.
Sarwar G, Corsi R, Allen D, Weschler C. The significance of secondary organic aerosol formation and growth in buildings: experimental and computational evidence. Atmos. Environ. 2003; 37: 1365-81. (Pubitemid 36294086)
Nojgaard JK, Bilde M, Stenby C et al. The effect of nitrogen dioxide on particle formation during ozonolysis of two abundant monoterpènes indoors. Atmos. Environ. 2006; 40: 1030-42. (Pubitemid 43088809)
Sarwar G, Corsi R. The effects of ozone/limonene reactions on indoor secondary organic aerosols. Atmos. Environ. 2007; 41: 959-73. (Pubitemid 44960903)
Zuraimi MS, Weschler CJ, Tham KW, Fadeyi MO. The impact of building recirculation rates on secondary organic aerosols generated by indoor chemistry. Atmos. Environ. 2007; 41: 5213-23. (Pubitemid 47049690)
Plaisance H, Desmettres P, Leonardis T et al. Passive sampling of glycol ethers and their acetates in indoor air. J. Environ. Monit. 2008; 10: 517-26. (Pubitemid 351490289)
EN ISO 16017-2 : 2003. Air intérieur, air ambiant et air des lieux de travail - Échantillonnage et analyse des composés organiques volatils par tube à adsorption/désorption thermique/ chromatographie en phase gazeuse capillaire - Partie 2 : Échantillonnage par diffusion.
Marlet C, Lognay G. Development and validation by accuracy profile of a method for the analysis of monoterpenes in indoor air by active sampling and thermal desorption-gas chromatography-mass spectrometry. Talanta. 2010; 82: 1230-9.
Bruno P, Caputi M, Caselli M et al. Reliability of a BTEX radial diffusive sampler for thermal desorption: field measurements. Atmos. Environ. 2005; 39: 1347-55.
Pennequin-Cardinal A, Plaisance H, Locoge N et al. Performances of the Radiello® diffusive sampler for BTEX measurements: Influence of environmental conditions and determination of modelled sampling rates, Atmos. Environ. 2005; 39: 2535-44.
Plaisance H, Leonardis T, Gerboles M. Assessment of uncertainty of benzene measurements by Radiello diffusive sampler. Atmos. Environ. 2008; 42: 2555-68.
Goupy J. Les plans d'expériences, Revue Modulad, 2006.
EN 13528-2 : 2003. Qualité de l'air ambiant - É chantillonneurs par diffusion pour la détermination des concentrations des gaz et des vapeurs - Exigences et méthodes d'essai - Partie 2 : Exigences spécifiques et méthodes d'essai.
Gerboles M, Buzica D, Amantini L. Modification of the Palmes diffusion tube and semi-empirical modelling of the uptake rate for monitoring nitrogen dioxide. Atmos. Environ. 2005; 39: 2579-92.