[en] This paper presents the results of an experimental analysis of the radiant ceiling systems in both heating and cooling modes coupled to its environment (fenestration, walls, internal loads and ventilation system). The main objective of this study is to present the results of the experimental analysis and measurement methods and its discussion. Two test chambers are adapted in a way to reproduce as good as possible the characteristics of the real offices located in Brussels (Belgium). Forty-six tests are performed to observe the influence of parameters such as the mass flow rate, supply water temperature, fenestration and ventilation system effects and thermal load distribution. Laboratory test results show that the influence of surfaces temperatures inside the room, especially the facade, is considerable.
Therefore, the system must be evaluated together with its designed environment and not as separate HVAC equipment.
Disciplines :
Mechanical engineering
Author, co-author :
Fonseca, Néstor; Universidad Tecnológica de Pereira, Facultad de Ingeniería Mecánica, Colombia
Cuevas, Cristian; Universidad de Concepción, Facultad de Ingeniería Mecánica, Chile
Lemort, Vincent ; Université de Liège - ULiège > Département d'aérospatiale et mécanique > Systèmes énergétiques
Language :
English
Title :
Radiant ceiling systems coupled to its environment part 1: Experimental analysis
F. Alamdari, and P. Hammond Improved data correlations for buoyancy-driven convection in rooms Building Services Engineering Research and Techonology 4 No. 3 1983 106 112
Spitler J., Pedersen C., Fisher D., Interior convective heat transfer in buildings with large ventilative flow rates, ASHRAE Transactions 97 (1) 505-515.
H. Awbi, and A. Hatton Mixed convection from heated room surfaces Energy and Buildings 32 2000 153 166
A. Novoselac, B. Burley, and J. Srebric New convection correlation for cooled ceiling panels in room with mixed and stratified airflow HVAC/R Research 12 No. 2 2006 279 294
M. Behne Is there a risk of draft in rooms with cooled ceilings. Measurement of air velocities and turbulences ASHRAE Transactions 1996 744 751 Symposia - SD 96-4-5
R. Kulpmann Thermal comfort and air quality in rooms with cooled ceilings - results of scientific investigations ASHRAE Transactions 1993 488 502 Symposia - DE 93-2-2
M. Behne Indoor air quality in rooms with cooled ceiling. Mixing ventilation or rather displacement ventilation? Energy and Buildings 30 1999 155 166
J. Fredriksson, M. Sandberg, and B. Moshfegh Experimental investigation of the velocity field and airflow pattern generated by cooling ceiling beams Building and Environment 36 2001 891 899
R. Karadag The investigation of relation between radiative and convective heat transfer coefficients at the ceiling in a cooled ceiling room Energy Conversion and Management 50 1 January 2009 1 5
S. Corgnati, M. Perino, G. Fracastoro, and P. Nielsen Experimental and numerical analysis of air and radiant cooling systems in offices Building and Environment 44 2009 801 806
T. Catalina, J. Virgone, and F. Kuznik Evaluation of thermal comfort using combined CFD and experimentation study in a test room equipped with a cooling ceiling Building and Environment 44 8 August 2009 1740 1750
N. Fonseca, C. Cuevas, and V. Lemort Radiant ceiling systems coupled to its environment part 2: dynamic modeling and validation Applied Thermal Engineering 2009 In revision
J. Bourdouxhe, B. Georges, and J. Lebrun Rapport No. 1, Etude Expérimentale du Plafond Rayonnant Chauffant et Rafraîchissant 1998 Laboratoire de Thermodynamique Applique Université de Lige Belgium
J. Bourdouxhe, B. Georges, A. Ternoveanu, and J. Lebrun Rapport No.4, Etude Expérimentale des Plafonds Rayonnants Chauffants et Rafraîchissants 1998 Laboratoire de Thermodynamique Applique Université de Lige Belgium
ANSI/ASHRAE Standard 41.1-1986 (RA 91) Standard Method for Laboratory Airflow Measurement 1991 American Society of Heating, Air-Conditioning and Refrigeration Engineers, Inc. Atlanta
ANSI/ASHRAE Standard 41.2-1987 (RA 92) Standard Method for Temperature Measurement 1992 American Society of Heating, Air-Conditioning and Refrigeration Engineers, Inc. Atlanta
ANSI/ASHRAE Standard 41.3-1989, Standard Method for Pressure Measurement, American Society of Heating, Air-Conditioning and Refrigeration Engineers, Inc., Atlanta.
ISO 5167-1 Measurement of Fluid Flow by Means of Pressure Differential Devices Part 1: Orifice Plates, Nozzles and Venturi Tubes Inserted in Circular Cross-Section Conduits Running Full 1991 International Organization for Standardization Geneva
N. Fonseca Methodology for uncertainty calculation of net total cooling effect estimation for rating room air conditioners and packaged terminal air conditioners International Journal of Refrigeration 32 6 2009 1472 1477
A. Fissore, and N. Fonseca Experimental study of the thermal balance of a window, design description Building and Environment 47 2007 3309 3321 (Pubitemid 46567695)
ISO GUM Guide to the Expression of Uncertainty Measurement First ed., 1993, corrected and reprinted 1995 International Organization for Standardization Geneva Switzerland
C. Cuevas, and J. Lebrun Re-commissioning of a Cooling Plant 2002 Faculty of Applied Sciences. University of Liege Belgium
Ashrae Handbook-HVAC Systems and Equipment Chapter 6 2004 American Society of Heating, Air-Conditioning and Refrigeration Engineers, Inc. Atlanta