Laboratory medicine & medical technology Orthopedics, rehabilitation & sports medicine
Author, co-author :
Forthomme, Bénédicte ; Université de Liège - ULiège > Département des sciences de la motricité > Rééducation du membre supérieur
Dvir, Zeevi
Crielaard, Jean-Michel ; Université de Liège - ULiège > Département des sciences de la motricité > Evaluation et entraînement des aptitudes physiques - Médecine physique et réadaptation fonctionnelle
Croisier, Jean-Louis ; Université de Liège - ULiège > Département des sciences de la motricité > Kinésithérapie générale et réadaptation
Language :
English
Title :
Isokinetic assessment of the shoulder rotators: A study of optimal test position
Arrigo CA, Wilk KE, Andrews JR. Peak torque and maximum work repetition during isokinetic testing of the shoulder internal and external rotators. Isokinet Exerc Sci (1994); 4: 171-175.
Bellew JW, Malone TR, Nitz AJ, Hart AL. Gender specificity in the age-related decline of strength: concentric versus eccentric. Isokinet Exerc Sci (1998); 7: 1-9.
Burnham RS, Bell G, Olenik L, Reid DC. Shoulder abduction strength measurement in football players: reliability and validity of two field tests. Clin J Sports Med (1995); 5: 90-94.
Cahalan TD, Johnson ME, Chao EYS. Shoulder strength analysis using the Cybex II isokinetic dynamometer. Clin Orthop Relat Res (1991); 271: 249-257.
Codine P, Bernard PL, Pocholle M, Benaim C, Brun V. Influence of sports discipline on shoulder rotator cuff balance. Med Sci Sports Exerc (1997); 29: 1400-1405.
Croisier JL, Mommer R, Lhermerout C, Crielaard JM. Bilan isocinétique des rotateurs internes et externes d'épaule: importance du positionnement articulaire. In: Pathologie de la coiffe des rotateurs de l'épaule (eds Pelissier, J, Simon, L, Rodineau, J). (1993), pp. 193-199. Masson, Paris.
Durall CJ, Davies GJ, Kernozek TW, Gibson MH, Fater DCW, Straker JS. The reproducibility of assessing arm elevation in the scapular plane on the Cybex 340. Isokinet Exerc Sci (2000); 8: 7-11.
Dvir Z. Isokinetics: Muscle Testing, Interpretation and Clinical Applications (2004). pp. 102-132. Churchill Livingstone, Edinburg.
Ellenbecker TS, Mattalino AJ. Concentric isokinetic shoulder internal and external rotation strength in professional baseball pitchers. J Orthop Sports Phys Ther (1997); 25: 323-328.
Forthomme B, Croisier JL, Crielaard JM. Proposal for the assessment protocols for different shoulder muscle groups. Isokinet Exerc Sci (2003a); 11: 69.
Forthomme B, Croisier JL, Huskin JP, Crielaard JM. Isokinetic assessment of shoulders with impingement syndrome following pain inhibition. Isokinet Exerc Sci (2003b); 11: 70-71.
Forthomme B, Croisier JL, Ciccarone G, Crielaard JM, Cloes M. Factors correlated with volleyball spike velocity. Am J Sports Med (2005); 33: 1513-1519.
Greenfield BH, Donatelli R, Wooden MJ, Wilkes J. Isokinetic evaluation of shoulder rotational strength between the plane of scapula and the frontal plane. Am J Sports Med (1990); 18: 124-127.
Gulick DT, Dustman CS, Ossowski LL, Outslay MD, Thomas CP, Trucano S. Side dominance does not affect dynamic control strength ratios in the shoulder. Isokinet Exerc Sci (2001); 9: 79-84.
Hageman PA, Mason DK, Rydlund KW, Humpal SA. Effects of position and speed on eccentric and concentric isokinetic testing of the shoulder rotators. J Orthop Sports Phys Ther (1989); 11: 64-69.
Handel M, Dickhuth HH, Mayer F, Gülch RW. Prerequisites and limitations to isokinetic measurements in humans. Investigations on a servomotor-controlled dynamometer. Eur J Appl Physiol (1996); 73: 225-230.
Hill AM, Pramanik S, McGregor AH. Isokinetic dynamometry in assessment of external and internal axial rotation strength of the shoulder: comparison of two positions. Isokinet Exerc Sci (2005); 13: 187-195.
Ivey FM, Calhoun JH, Rusche K, Bierschenk J. Isokinetic testing of shoulder strength: normal values. Arch Phys Med Rehabil (1985); 66: 384-386.
Kakebeeke TH, Lechner HE, Handschin C. Reproducibility analysis of isokinetic strength measurements of shoulder and elbow muscles in subjects with spinal cord injury. Isokinet Exerc Sci (2005); 13: 279-284.
Kuhlman JR, Iannotti JP, Kelly MJ, Riegler FX, Gevaert ML, Ergin TM. Isokinetic and isometric measurement of strength of external rotation and abduction of the shoulder. J Bone Joint Surg (1992); 74: 1320-1333.
Madsen OR. Torque, total work, power, acceleration energy and acceleration time assessed on a dynamometer: reliability of knee and elbow extensor and flexor strength measurement. Eur J Appl Physiol (1996a); 74: 206-210.
Madsen OR. Trunk extensor and flexor strength measured by the Cybex 6000 dynamometer. Assessment of short-term and long-term reproducibility of several strength variables. Spine (1996b); 21: 2770-2776.
Magnusson SP, Gleim GW, Nicholas JA. Subject variability of shoulder abduction strength testing. Am J Sports Med (1990); 18: 349-353.
Mandalidis DG, Florides P, O'Brien M. Scapular plane isokinetic shoulder elevation: effect of shoulder and motor centers of rotation transient misalignment on moment data. Isokinet Exerc Sci (2001a); 9: 91-99.
Mandalidis DG, Donne B, O'Regan M, O'Brien M. Effect of transient moment-oscillations on the reliability of isokinetic shoulder elevation in the scapular plane. Isokinet Exerc Sci (2001b); 9: 101-109.
Mandalidis DG, Donne B, O'Regan M, O'Brien M. Reliability of isokinetic internal and external rotation of the shoulder in the scapular plane. Isokinet Exerc Sci (2001c); 9: 65-72.
Mayer F, Horstmann T, Kranenberg U, Röcker K, Dickhuth HH. Reproducibility of isokinetic peak torque and angle at peak torque in the shoulder joint. Int J Sports Med (1994a); 15: S26-S31.
Mayer F, Horstmann T, Röcker K, Heitkamp HC, Dickhuth HH. Normal values of isokinetic maximum strength, the strength/velocity curve, and the angle at peak torque of all degrees of freedom in the shoulder. Int J Sports Med (1994b); 15: S19-S25.
Mayer F, Baur H, Hirschmüller A, Heitkamp HC, Horstmann T, Dickhuth HH. The quantification of reciprocal shoulder strength relation in various working modes at different movement velocities. Isokinet Exerc Sci (2001a); 9: 73-77.
Mayer F, Horstmann T, Bäurle W, Grau S, Handel M, Dickhuth HH. Diagnostics with isokinetic devices in shoulder measurements - potentials and limits. Isokinet Exerc Sci (2001b); 9: 19-25.
van Meeteren J, Roebroeck ME, Stam HJ. Test-retest reliability in isokinetic muscle strength measurements of the shoulder. J Rehabil Med (2002); 34: 91-95.
Nitschke JE. Reliability of isokinetic torque measurements: a review of the literature. Aust J Physiother (1992); 38: 125-134.
Otis JC, Warren RF, Backus SI, Santner TJ, Mabrey JD. Torque production in the shoulder of the normal young adult male. The interaction of function, dominance, joint angle and angular velocity. Am J Sports Med (1990); 18: 119-123.
Phillips BA, Lo SK, Mastaglia FL. Isokinetic and isometric torque values using a Kin-Com dynamometer in normal subjects aged 20 to 69years. Isokinet Exerc Sci (2000); 8: 147-159.
Scoville CR, Arciero RA, Taylor DC, Stoneman PD. End range eccentric antagonist/concentric agonist strength ratios: a new perspective in shoulder strength assessment. J Orthop Sports Phys Ther (1997); 25: 203-207.
Smith J, Padgett DJ, Kotajarvi BR, Eischen JJ. Isokinetic and isometric shoulder rotation strength in the protracted position: a reliability study. Isokinet Exerc Sci (2001); 9: 119-127.
Soderberg GJ, Blaschak MJ. Shoulder internal and external rotation peak torque production through a velocity spectrum in differing positions. J Orthop Sports Phys Ther (1987); 8: 518-524.
Tis LL, Maxwell T. The effect of positioning on shoulder isokinetic measures in females. Med Sci Sports Exerc (1996); 28: 1188-1192.
Walker SW, Couch WH, Boester GA, Sprowl DW. Isokinetic strength of the shoulder after repair of a torn rotator cuff. J Bone Joint Surg (1987); 69-A: 1041-1044.
Walmsley RP. Movement of the axis of rotation of the glenohumeral joint while working on the Cybex II dynamometer. Part II: abduction/adduction. Isokinet Exerc Sci (1993); 3: 21-26.
Walmsley RP, Dias JM. Intermachine reliability of isokinetic concentric measurements of shoulder internal and external peak torque. Isokinet Exerc Sci (1995); 5: 75-80.
Walmsley RP, Szybbo C. A comparative study of the torque generated by the shoulder internal and external rotator muscles in different positions and at varying speeds. J Orthop Sports Phys Ther (1987); 9: 217-222.
Zemach L, Almoznino S, Barak Y, Dvir Z. Quadriceps insufficiency in patients with knee compromise: how many velocities should an isokinetic test protocol consist of ? Isokinet Exerc Sci (2009); 17: 129-134.