[en] The purpose of this study was to assess the impact of freezing and thawing on MR images of equine feet examined ex vivo. Nine equine cadaver digits were first imaged at room temperature (T0). Among the 9 digits, 3 (group 1) were imaged in a 3 Tesla MR system after one and after 2 freezing-thawing cycles. Digits of group 1 were thawed in a cold room at 4°C for 36h. Three other digits (group 2) were imaged after one freezing-thawing cycle. Digits of group 2 were thawed in a cold room at 4°C and then rescanned after 24h at room temperature. The last 3 digits (group 3) were scanned after one freezing-thawing cycle. Digits of group 3 were thawed at room temperature for 24h. Sequences used were Spin Echo (SE) T1, Turbo Spin Echo (TSE) T2 and proton density (PD), Short Tau Inversion Recovery (STIR), Double Echo Steady State (DESS), 3D Gradient Echo (GE) T1 and 2D GE T2*. Images obtained on the fresh limbs at room temperature were subjectively compared side by side to images obtained at the different freezing-thawing cycles. A quantitative analysis to assess signal change between examinations was realized by measuring signal to noise ratio (SNR). Visibility and margination of the anatomical structures of the foot and overall image quality were subjectively considered unchanged except for the hoof where the lamina was considered less visible distally after freezing and thawing in the GE T2* and in TSE T2 and PD sequences. Quantitative analysis demonstrated SNR changes in the bone marrow only in the distal phalanx in the SE T1 sequence when the feet were thawed at room temperature. When the feet were thawed in a cold room at 4°C, bone marrow SNR changes were present in the SE T1, GE T1 and TSE PD sequences. Signal changes were significant in the synovial recess when the thawing process was made at 4°C and not when the thawing process was at ambient temperature. The soft tissue structures and the hoof capsule showed significant changes with an increase of SNR, except in STIR, after freezing and thawing at 4°C and at room temperature. SNR changes in the soft tissues were mainly present in GE sequences.
Disciplines :
Veterinary medicine & animal health
Author, co-author :
Bolen, Géraldine ; Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Département clinique des animaux de compagnie et des équidés
Haye, Dimitri
Dondelinger, Robert ; Université de Liège - ULiège > Département des sciences cliniques > Département des sciences cliniques
Massart, Laurent
Busoni, Valeria ; Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Imagerie médicale
Language :
English
Title :
Impact of successive freezing-thawing cycles on 3-T magnetic resonance images of the digits of isolated equine limbs
Publication date :
June 2011
Journal title :
American Journal of Veterinary Research
ISSN :
0002-9645
eISSN :
1943-5681
Publisher :
American Veterinary Medical Association, Schaumburg, United States - Illinois
Dyson S. Navicular disease and other soft tissue causes of palmar foot pain. In: Ross M, Dyson S, eds. Diagnosis and management of lameness in the horse. St Louis: Saunders, 2003;286-299.
Whitton RC, Buckley C, Donovan T, et al. The diagnosis of lameness associated with distal limb pathology in a horse: a comparison of radiography, computed tomography and magnetic resonance imaging. Vet J 1998;155:223-229.
Widmer WR, Buckwalter KA, Fessler JF, et al. Use of radiography, computed tomography and magnetic resonance imaging for evaluation of navicular syndrome in the horse. Vet Radio l Ultrasound 2000;41:108-116.
Tucker RL, Sande RD. Computed tomography and magnetic resonance imaging of the equine musculoskeletal conditions. Vet Clin North Am Equine Pract 2001;17:145-157.
Dyson S, Murray R, Schramme M, et al. Magnetic resonance imaging of the equine foot: 15 horses. Equine Vet J 2003;35:18-26.
Dyson S, Murray R, Schramme M, et al. Lameness in 46 horses associated with deep digital flexor tendonitis in the digit: diagnosis confirmed with magnetic resonance imaging. Equine Vet J 2003;35:681-690.
Murray R, Dyson S, Schramme M, et al. Magnetic resonance imaging of the equine digit with chronic laminitis. Vet Radiol Ultrasound 2003;44:609-617.
Zubrod CJ, Schneider RK, Tucker RL, et al. Use of magnetic resonance imaging for identifying subchondral bone damage in horses: 11 cases (1999-2003). J Am Vet Med Assoc 2004;224:411-418.
Dyson S, Murray R, Schramme M, et al. Collateral desmitis of the distal interphalangeal joint in 18 horses (2001-2002). Equine Vet J 2004;36:160-166.
Busoni V, Heimann M, Trenteseaux J, et al. Magnetic resonance imaging findings in the equine deep digital flexor tendon and distal sesamoid bone in advanced navicular disease-an ex vivo study. Vet Radiol Ultrasound 2005;46:279-286.
Dyson S, Murray R, Schramme M. Lameness associated with foot pain: results of magnetic resonance imaging in 199 horses (January 2001-December 2003) and response to treatment. Equine Vet J 2005;37:113-121.
Kinns J, Mair TS. Use of magnetic resonance imaging to assess soft tissue damage in the foot following penetrating injury in 3 horses. Equine Vet Educ 2005;17:69-73.
Mair TS, Kinns J. Deep digital flexor tendonitis in the equine foot diagnosed by low-field magnetic resonance imaging in the standing patient: 18 cases. Vet Radiol Ultrasound 2005;46:458-466.
Zubrod CJ, Farnsworth KD, Tucker RL, et al. Injury of the collateral ligaments of the distal interphalangeal joint diagnosed by magnetic resonance. Vet Radiol Ultrasound 2005;46:11-16.
Murray R, Schramme M, Dyson S, et al. Magnetic resonance imaging characteristics of the foot in horses with palmar foot pain and control horses. Vet Radiol Ultrasound 2006;47:1-16.
Murray R, Blunden T, Schramme M, et al. How does magnetic resonance imaging represent histologic findings in the equine digit? Vet Radiol Ultrasound 2006;47:17-31.
Dyson S, Murray R. Magnetic resonance imaging evaluation of 264 horses with foot pain: the podotrochlear apparatus, deep digital flexor tendon and collateral ligaments of the distal interphalangeal joint. Equine Vet J 2007;39:340-343.
Dyson S, Murray R. Use of concurrent scintigraphic and magnetic resonance imaging evaluation to improve understanding of the pathogenesis of injury of the podotrochlear apparatus. Equine Vet J 2007;39:365-369.
Kofler J, Kneissl S, Malleczek D. MRI and CT diagnosis of acute desmopathy of the lateral collateral sesmoidean (navicular) ligament and long-term outcome in a horse. Vet J 2007;174:410-413.
Sherlock CE, Kinns J, Mair TS. Evaluation of foot pain in the standing horse by magnetic resonance imaging. Vet Rec 2007;161:739-744.
Cohen JM, Schneider RK, Zubrod CJ, et al. Desmitis of the distal digital annular ligament in seven horses: MRI diagnosis and surgical treatment. Vet Surg 2008;37:336-344.
Dyson S, Blunden T, Murray R. The collateral ligaments of the distal interphalangeal joint: magnetic resonance imaging and post-mortem observations in 25 lame and 12 control horses. Equine Vet J 2008;40:538-544.
Nagy A, Dyson S, Murray R. Radiographic, scintigraphic and magnetic resonance imaging findings in the palmar processes of the distal phalanx. Equine Vet J 2008;40:57-63.
Sherlock C, Mair T, Blunden T. Deep erosions of the palmar aspect of the navicular bone diagnosed by standing magnetic resonance imaging. Equine Vet J 2008;40:684-692.
Gutierrez-Nibeyro SD, White NA II, Werpy NM, et al. Magnetic resonance imaging findings of desmopathy of the collateral ligaments of the equine distal interphalangeal joint. Vet Radiol Ultrasound 2009;50:21-31.
Denoix J-M, Crevier N, Roger B, et al. Magnetic resonance imaging of the equine foot. Vet Radiol Ultrasound 1993;34:405-411.
Kleiter M, Kneissl S, Stanek C, et al. Evaluation of magnetic resonance imaging techniques in the equine digit. Vet Radiol Ultrasound 1999;40:15-22.
Widmer WR, Buckwalter KA, Hill MA, et al. A technique for magnetic resonance imaging of equine cadaver specimens. Vet Radiol Ultrasound 1999;40:10-14.
Asperio RM, Marzola P, Sbarbati A, et al. Comparison of results of scanning electron microscopy and magnetic resonance imaging before and after administration of a radiographic contrast agent in the tendon of the deep digital flexor muscle obtained from horse cadavers. Am J Vet Res 2000;61:321-325.
Busoni V, Snaps F. Effect of deep digital flexor tendon orientation on magnetic resonance imaging signal intensity in isolated equine limbs-the magic angle effect. Vet Radiol Ultrasound 2002;43:428-430.
Busoni V, Snaps F, Trenteseaux J, et al. Magnetic resonance imaging of the palmar aspect of the equine podotrochlear apparatus: normal appearance. Vet Radiol Ultrasound 2004;45:198-204.
Murray R, Roberts B, Schramme M, et al. Quantitative evaluation of equine deep digital flexor tendon morphology using magnetic resonance imaging. Vet Radiol Ultrasound 2004;45:103-111.
Spriet M, Mai W, McKnight A. Asymmetric signal intensity in normal collateral ligaments of the distal interphalangeal joint in horses with a low-field MRI system due to the magic angle effect. Vet Radiol Ultrasound 2007;48:95-100.
Smith M, Dyson S, Murray R. Is a magic angle effect observed in the collateral ligaments of the distal interphalangeal joint or the oblique sesamoidean ligaments during standing magnetic resonance imaging? Vet Radiol Ultrasound 2008;49:509-515.
Arble JB, Mattoon JS, Drost WT, et al. Magnetic resonance imaging of the initial active stage of equine laminitis at 4.7T. Vet Radiol Ultrasound 2009;50:3-12.
Spriet M, McKnight A. Characterization of the magic angle effect in the equine deep digital flexor tendon using a low-field magnetic resonance system. Vet Radiol Ultrasound 2009;50:32-36.
Hevesi A, Stanek Ch, Garamvolgyi R, et al. Comparison of the navicular region of newborn foals and adult horses by magnetic resonance imaging. Physiol Pathol Clin Med 2004;51:143-149.
Keller MD, Galloway GJ, Pollitt CC. Magnetic resonance microscopy of the equine hoof wall: a study of resolution and potential. Equine Vet J 2006;38:461-466.
Nott KP, Evans SD, Hall LD. Quantitative magnetic resonance imaging of fresh and frozen-thawed trout. Magn Reson Imaging 1999;17:445-455.
Niitsu M, Nakai T, Ikeda K, et al. High-resolution MR imaging of the knee at 3 T. Acta Radiol 2000;41:84-88.
Saupe N, Prussmann KP, Luechinger R, et al. MR imaging of the wrist: comparison between 1.5- and 3-T MR imaging-preliminary experience. Radiology 2005;234:256-264.
Hart H Jr, Bottomley P, Edelstein W, et al. Nuclear magnetic resonance imaging: contrast-to-noise ratio as a function of strength of magnetic field. AJR 1983;141:1195-1201.
Rutt B, Lee D. The impact of field strength on image quality in MRI. J Magn Reson Imaging 1996;6:57-62.
Vetter D, Kastler B. Facteurs de qualité de l'image en IRM. In: Kastler B, Vetter D, Patay Z, al, eds. Comprendre l'IRM, manuel d'auto-apprentissage. 5th ed. Paris: Masson, 2003;115-131.
Maubon AJ, Ferru JM, Berger V, et al. Effect of field strength on MR images: comparison of the same subject at 0.5, 1.0, and 1.5 T. Radiographics 1999;19:1057-1067.
Chandler JE, Ruiz CF, Adkinson RW, et al. Relationship between final temperature, thaw rate, and quality of bovine semen. J Dairy Sci 1984;67:1806-1812.
Calamera JC, Buffone MG, Doncel GF, et al. Effect of thawing temperature on the motility recovery of cryopreserved human spermatozoa. Fertil Steril 2010;93:789-794.
Bolen G, Haye D, Dondelinger R, et al. Magnetic resonance signal changes during time in equine limbs refrigerated at 4°C. Vet Radiol Ultrasound 2010;51:19-24.
Koizumi M, Naito S, Ishida N, et al. A dedicated MRI for food science and agriculture. Food Sci Technol Res 2008;14:74-82.
Kurmis A, Slavotinek J, Barber C, et al. An unusual MR signal reduction artefact in an incompletely thawed cadaver spine specimen. Radiography 2009;15:86-90.
Petrén-Mallmin M, Ericsson A, Rauschning W, et al. The effect of temperature on MR relaxation times and signal intensities for human tissues. Magn Reson Mater Phys Biol Med 1993;1:176-184.
Hall LD, Evans SD, Nott KP. Measurement of textural changes of food by MRI relaxometry. Magn Reson Imaging 1998;16:485-492.
Evans SD, Nott KP, Kshirsagar AA, et al. The effect of freezing and thawing on the magnetic resonance imaging parameters of water in beef, lamb and pork meat. Int J Food Sci Technol 1998;33:317-328.
Virta A, Komu M, Kormano M, et al. Magnetization transfer in protein solutions at 0.1 T: dependence on concentration, molecular weight, and structure. Acad Radiol 1995;2:792-798.
Renou JP, Foucat L, Bonny JM. Magnetic resonance imaging studies of water interactions in meat. Food Chem 2003;82:35-39.
Damyanovich AZ, Staples JR, Marshall KW. The effects of freeze/thawing on human synovial fluid observed by 500 MHz 1H magnetic resonance spectroscopy. J Rheumatol 2000;27:746-752.
Bustabad OM. Weight loss during freezing and the storage of frozen meat. J Food Eng 1999;41:1-11.
Giannini S, Buda R, Di Caprio F, et al. Effects of freezing on the biomechanical and structural properties of human posterior tibial tendons. Int Orthop 2008;32:145-151.
Schick F, Dammann F, Lutz O, et al. Adapted techniques for clinical MR imaging of tendons. Magn Reson Mater Phys Biol Med 1995;3:103-107.
Guiheneuf TM, Parker AD, Tessier JJ, et al. Authentication of the effect of freezing/thawing of pork by quantitative magnetic resonance imaging. Magn Reson Chem 1997;35:S112-S118.