[en] The purpose of this study was to establish a standardized protocol in order to obtain accurate and reproducible cardiac output (CO) measurements by the thermodilution technique in the unsedated calf. In 5 healthy calves, the effect of various temperatures, volumes, rates, means and sites of injection of the thermal indicator were tested for their effect on accuracy and reproducibility of CO measurement by the thermodilution technique, the Fick method being used as the standard technique. Five milliliters of an iced 5% dextrose solution per 100 kg body weight constituted the correct amount of thermal indicator. Manual injection of the indicator bolus and/or injection of this bolus through the proximal lumen of a thermodilution Swan-Ganz catheter gave poor results of CO measurements by the thermodilution technique. On the other hand, results of CO measurements were highly reliable when the bolus injection was performed by an ECG-synchronized injection pump and/or through a right atrial catheter with a larger diameter and a shorter length than the classical Swan-Ganz catheter. It was concluded that an iced 5% solution of dextrose (5 ml/100 kg body weight) injected through a right atrial catheter by an ECG-synchronized pump gives the most accurate and reproducible CO measurements by the thermodilution technique in unsedated calves.
Disciplines :
Anatomy (cytology, histology, embryology...) & physiology Veterinary medicine & animal health
Author, co-author :
Amory, Hélène ; Université de Liège - ULiège > Physiology
Linden, Annick ; Université de Liège - ULiège > Département des maladies infectieuses et parasitaires
Desmecht, Daniel ; Université de Liège - ULiège > Département de morphologie et pathologie
Rollin, Frédéric ; Université de Liège - ULiège > Département clinique des animaux de production (DCP)
Genicot, B.
Lekeux, Pierre ; Université de Liège - ULiège > Département de sciences fonctionnelles > Physiologie
Language :
English
Title :
Validation of the Thermodilution Technique for the Estimation of the Cardiac Output in the Unsedated Calf
Publication date :
1991
Journal title :
Journal of Veterinary Medicine. A, Physiology, Pathology, Clinical Medicine
ISSN :
0931-184X
eISSN :
1439-0442
Publisher :
Blackwell Publishing, Berlin, Germany
Volume :
38
Issue :
6
Pages :
409-417
Peer reviewed :
Peer Reviewed verified by ORBi
Name of the research project :
Convention n°5131 A
Funders :
F.R.S.-FNRS - Fonds de la Recherche Scientifique IRSIA - Institut pour l'Encouragement de la Recherche Scientifique dans l'Industrie et l'Agriculture
Arvidsson S., Bergqvist D., Haglund U., Lindblad B. (1983) Cardiac output measurements with thermodilution and radioactive microspheres. A comparative study in cats. Scand. J. clin. Lab. Invest. 43:617-620.
Berger R.L., Weisel R.D., Vito L., Dennis R.C., Hechtman H.B. (1976) Cardiac output measurement by thermodilution during cardiac operations. Ann. Thor. Surg. 21(1):43-47.
Branthwaite M.A., Bradley R.D. (1968) Measurement of cardiac output by thermal dilution in man. J. Appl. Physiol. 24:434-438.
Bristow J.D., Ferguson R.E., Mintz F., Rapaport E. (1963) Thermodilution studies of ventricular changes due to isoproterenol and bleeding. J. Appl. Physiol. 18:126-133.
Butler H.C. (1962) Subcutaneous relocation of the carotid artery for experimental purposes. Am. J. Vet. Res. 23:165-166.
Callaghan M.L., Weintraub W.H., Coran A.G. (1976) Assessment of thermodilution cardiac output in small subjects. J. Pediatr. Surg. 11(5):629-633.
Dyson D.H., Allen D.G., McDonell W.N. (1985) Comparison of three methods for cardiac output determination in cats. Am. J. Vet. Res. 46:2546-2552.
Elkayam U., Berkley R., Azen S., Weber L., Geva B., Henry W.L. (1983) Cardiac output by thermodilution technique: effect of injectate's volume and temperature on accuracy and reproducibility in the critically ill patient. Chest 84:418-422.
Evonuk E., Imig C.J., Greenfield W., Eckstein J.W. (1961) Cardiac output measured by thermal dilution of room temperature injectate. J. Appl. Physiol. 16:271-275.
Fegler G. (1954) Measurement of cardiac output in anaesthetized animals by a thermo‐dilution method. Q. J. Exp. Physiol. 37:153-164.
Fisher E.W., Dalton R.G. (1961) Determination of the cardiac output of cattle and horses by the injection method. Brit. Vet. J. 118:143-151.
Ganz W., Donoso R., Marcus H.S., Forrester J.S., Swan H.J.C. (1971) A new technique for measurement of cardiac output by thermodilution in man. Am. J. Cardiol. 27:392-396.
Ganz W., Swan H.J.C. (1972) Measurement of blood flow by thermodilution. Am. J. Cardiol. 29:241.
Goodyer A.V.N., Huvos A., Eckhardt W.F., Ostberg R.H. (1959) Thermal dilution curves in the intact animal. Circ. Res. 7:432-441.
Hanwell A., Linzell J.L. (1972) Validation of the thermodilution technique for the estimation of cardiac output in the rat. Comp. Biochem. Physiol. 41 A:647-657.
Holt J.P. (1966) Symposium on measurement of left ventricular volume ‐‐‐ Part II. Indicator‐ dilution methods: indicators, injection, sampling and mixing problems in measurement of ventricular volumes. Am. J. Cardiol. 18:208-224.
Khalil H.H., Richardson T.Q., Guyton A.C. (1966) Measurement of cardiac output by thermal‐dilution and direct Fick methods in dogs. J. Appl. Physiol. 21:1131-1135.
Kohanna F.H., Cunningham J.N. (1977) Monitoring of cardiac output by thermodilution after open‐heart surgery. J. Thorac. Cardiovasc. Surg. 73:451-457.
Kuipers J.R.G., Sidi D., Heymann M.A., Rudolph A.M. (1982) Comparison of methods of measuring cardiac output in newborn lambs. Pediatr. Res. 16:594-598.
Kuwahara M., Hirose H., Sugano S. (1988) Alteration in cardiovascular function of piglets during the growth process. Jpn. J. Vet. Sci. 50:990-995.
Lekeux P., Hajer R., Breukink H.J. (1984) Pulmonary function testing in calves: technical data. Am. J. Vet. Res. 45:342-345.
Levett J.M., Replogle R.L. (1979) Thermodilution cardiac output: a critical analysis and review of the literature. J. Surg. Res. 27:392-404.
Little R.A., Yate D.W., Reynolds M.I., Hadfield J.M. (1980) Changes in cardiac output and its distribution after non‐haemorrhagic injury in the rat. Br. J. Exp. Pathol. 61:421-428.
McGuirk S.M., Welker F.H., Muir W.W., Hull B.L. (1984) Thermodilution curves for diagnosis of ventricular septal defect in cattle. J. Am. Vet. Med. Assoc. 184(9):1141-1145.
Milne D.W., Muir W.W., Skarda R.T., Fregin G.F., Nicholl J.K. (1977) The hemodynamic response of the horse to swimming with and without furosemide. J. Eq. Med. Surg. 1:331-335.
Moodie D.S., Feldt R.H., Kaye M.P., Strelow D.A., Van der Hagen L.J. (1978) Measurement of cardiac output by thermodilution: development of accurate measurements at flows applicable to the pediatric patient. J. Surg. Res. 25:305-311.
Muir W.W., Skarda R.T., Milne D.W. (1976) Estimation of cardiac output in the horse by thermodilution techniques. Am. J. Vet. Res. 37:697-700.
Muller B., Mannesmann G. (1981) Measurement of cardiac output by the thermodilution method in rats. II. Simultaneous measurement of cardiac output and blood pressure in conscious rats. J. Pharmacol. Methods 5:29-34.
Olsson B., Pool J., Vandermooten P., Varnauskas E., Wassen R. (1970) Validity and reproducibility of determination of cardiac output by thermodilution in man. Cardiol. 55:136-148.
Rapaport E. (1966) Usefulness and limitations of thermal washout techniques in ventricular measurement. Am. J. Cardiol. 18:226-234.
Sanmarco M.E., Philips C.M., Marquez L.A., Hall C., Davila J.C. (1971) Measurement of cardiac output by thermal dilution. Am. J. Cardiol. 28:54-58.
Serteyn D., Coppens P., Mottard E., Philippart C., Lamy M. (1987) Myopathie postanesthésique équine: mesure de paramètres respiratoires et hémodynamiques. Ann. Méd. Vét. 131:123-131.
Sleeper J.C., Thompson H.K., McIntosh H.D., Elston R.C. (1962) Reproducibility of results obtained with indicator‐dilution technique for estimating cardiac output in man. Circ. Res. 11:712-720.
Sorensen M.B., Bille‐Brahe N.E., Engell H.C. (1975) Cardiac output measurement by thermal dilution. Ann. Surg. 183:67-72.
Vliers A.C.A.P., Visser K.R., Zijlstra W.G. (1973) Analysis of indicator distribution in the determination of cardiac output by thermal dilution. Cardiovasc. Res. 7:125-132.
Vliers A.C.A.P., Oeseburg B., Visser K.R., Zijlstra W.G. (1973) Choice of detection site for the determination of cardiac output by thermal dilution: the injection‐thermistor‐catheter. Cardiovasc. Res. 7:133-138.
Weisel R.D., Berger R.L., Hechtman H.B. (1975) Measurement of cardiac output by thermodiiution. N. Engl. J. Med. 292:682-684.
Weisel R.D., Vito L., Dennis R.C., Berger R.L., Hechtman H.B. (1975) Clinical applications of thermodilution cardiac output determinations. Am. J. Surg. 129:449-454.
Wetmore L.A., Derksen F.J., Blaze C.A., Eyster G.E. (1987) Mixed venous oxygen tension as an estimate of cardiac output in anesthetized horses. Am. J. Vet. Res. 48:971-976.
Wyse S.D., Pfitzner J., Rees A., Lincoln J.C.R., Branthwaite M.A. (1975) Measurement of cardiac output by thermal dilution in infants and children. Thorax 30:262-265.
Yang S.S., Bentivoglio L.G., Maranhao V., Goldberg H. (1988) Cardiac Output. From cardiac catheterization data to hemodynamic parameters, F. A. Davis Company (Ed), Philadelphia.; .