No document available.
Abstract :
[en] Climate change challenges the long-term robustness of building energy performance regulations, which were
largely developed under historical climate assumptions. This study assesses the Walloon Energy Performance of
Buildings (EPB) standard in Belgium under historical and projected climates, including end-of-century SSP5-8.5
conditions. Dynamic simulations were conducted on a representative detached dwelling for three Walloon EPB
envelope performance levels, expressed through the regulatory K-level indicator: K70, K45 and K35. The analysis
compares specific primary energy demand and overheating degree-hours, while testing passive strategies based on
solar protection and controlled night ventilation. The results show that stricter envelope requirements substantially
reduce heating-related demand but also shift the energy balance toward a greater relative contribution of cooling
and ventilation. Under a mixed energy-vector assumption, with gas for heating and domestic hot water and
electricity for cooling and ventilation, the most recent envelope requirement, K35, achieves the lowest specific
primary energy demand. When an indicative annual photovoltaic production of 4400 kWh/year, derived from
additional TRNSYS simulations for a 26 m² south-facing PV array, is included, K35 remains below the current
Walloon EPB threshold under historical and mid-century climates, but slightly exceeds it under the 2081–2100
SSP5-8.5 climate. At the same time, K35 exhibits the highest overheating risk. Solar protection and controlled
night ventilation reduce overheating degree-hours, with additional benefits at higher airflow rates. However, this
effect remains climate and control dependent, and the available night-time cooling potential becomes insufficient
to fully offset end-of-century overheating risk. These results suggest that passive strategies alone may become
insufficient under extreme future climates, potentially inducing a growing need for hybrid or active cooling
support. The findings reveal a tension between energy efficiency and thermal resilience in highly insulated
dwellings and support the integration of dynamic, climate-responsive criteria into EPB regulations, including
explicit assessment of overheating risk, solar control, and night ventilation performance.